Hochiki FNV-VoiceNET datasheet

File Preview
File Preview
Click below to download for free

File Data

Name hochiki-fnv-voicenet-datasheet-7130486925.pdf
Type PDF
Size 754.53 KB
Downloads

Text Preview

Features Multiplex 6 Channel Distributed Audio Fire Phone Area of Rescue Fan Damper Control capability System components added as needed 2 Channel Digital Message Repeater Microphone Page to any zone RS 485 Communication Protocol Supervised Installation and Operation Sound Voice Recordings in Alarm and Alert Signals to 4 Minute Message Capacity with 12VDC or 24VDC Fire Alarm Panel with Analog Addressable and based Fire Alarm Panels Minute Message Restart on Microphone Key in the USA Hochiki VoiceNET High Rise Evacuation operates in conjunction with the Fire Alarm Panel FACP in a building to provide response to life safety emergencies The Hochiki VoiceNET includes all necessary to provide an effective voice evacuation The Hochiki VoiceNET can be custom to satisfy the needs of any high rise Fire department authorities can easily take of evacuation or relocation procedures emergencies Building management and fire can monitor and control emergency even before the professionals arrive VoiceNET system includes capacity for 6 of simultaneous audio This provides for stay in place or other public address and automatic messages Fighter Phones or Warden Stations may be as required Area of Rescue stations can handicapped occupants that help is on way VoiceNET High Rise Voice Evacuation System CONTROL Configuration System Includes Master Panel FNV MP Master Mic Control 16 switch control points Dual Channel DMR High speed communication loop Distributed Panel FNV DP 4 Output Zones may be configured for 8 Dual Channel Audio Interface Dual Channel Amplification Optional Integrated Fire Phone Area of Rescue Number of distributed panels to be Determined by building specifications System Configuration Up to 256 Distributed Panels FNV DP And up to 2028 monitor and control points Village Drive Suite 100 Buena Park CA 90621 2268 714.522.2246 www hochiki com Panel Panel Evacuation Circuits AWG AWG Twisted Pair Phone Phone Phone Panel Evacuation Circuits Phone Phone VoiceNET Capabilities Loop Pair Category 5 Feet between panels Feet Total System Loop and 6 Audio Channels Simultaneously Speed RS 485 Communications or Style Field Selectable End Control Panel CONTROL PHONE CONTROL VoiceNET Rise Multiplex Floor Typical Riser Diagram 485 LOOP Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor Village Drive Suite 100 Park CA 90621 2268 Speaker Strobe Fighter Phone Jack of Rescue Station Engineering Specifications VoiceNET High Rise voice evacuation system shall be Hochiki Series VoiceNET FNV High Rise or approved VoiceNET FNV system shall include one Master Panel and one or more Distributed The system shall be microprocessor based and shall be compatible for use with closures from the Fire Alarm Control Panel FACP The system shall have a high communication bus and have the capacity for 6 channels of audio and data on a single of wires The field wiring for the communication bus may be configured for either Style 4 Style 7 supervision The system shall have the capacity for Fire Fighters Phone Area of communication and also have the capacity for Fan Damper control with monitored The system shall have a minimum capacity of 2028 monitor and control points Master Panel shall contain an integral microphone dual channel digital message repeater and digital tone generator 120 VAC power supply and battery charger The system be modular in design and shall be expandable such that additional system control points be configured The system shall include integral self diagnostic routines that shall monitor system status and shall indicate the precise type of trouble conditions they occur in the system A trouble condition within the system shall cause a trouble to be transmitted to the FACP panels shall provide a minimum of 4 Class B speaker circuits expandable to total Alternately panel may be configured for 4 Class A speaker circuits up to 8 total may be configured for 1 to 8 amplifiers Panel must provide up to 6 simultaneous audio up to 8 Fire Phone circuits up to 4 Area of Refuge circuits and up to two loops Amplifiers will contain their own power supplies battery chargers and auxiliary power for other components Speaker circuits shall be supervised for short open circuit conditions and shall be able to withstand transient or continuous short circuit without damage to the system may be configured for General Alarm All Call operation Alarm by Zone or Above Floor Below as required Contact closures shall allow immediate broadcast of an signal and evacuation message to the appropriate area Non Alarm areas may receive tones and messages as required or activated by the FACP alarm signal evacuation message shall be broadcast until the FACP is reset or until personnel interrupt the broadcast with a manual page prevent unauthorized tampering the voice evacuation system shall disable the microphone the microphone is keyed continuously for 3 minutes or more Systems that do not have this shall not be acceptable are subject to change without notice Specifications provided for information only and no responsibility is assumed Hochiki America Inc for their use

Related Files