HONEYWELL FOCUSPRO 6000 USER MANUAL (PDF)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | honeywell-focuspro-6000-user-manual-pdf-9253806147.pdf |
---|---|
Type | |
Size | 1.97 MB |
Downloads |
Text Preview
Programmable Guide Series and save these instructions help please visit yourhome honeywell com controls card holder Button to override programmed control buttons to set preferred temperature display buttons to select the displayed just each button change on the task screen battery inside the SET to change Current time Current day Current program the FAN to select Fan runs only heating or system is on Fan runs heat Only heat pumps with heat Clock Day Battery On Recovery buttons the button beneath function to view change settings change on the task setting Status On Cooling system on On Heating system on the SYSTEM button select Heating system control Cooling system control All systems off Thermostat selects heating cooling depending on the temperature Heat Emergency Heat control is locked out models only am Schedule can program four time periods each day with different settings for weekdays weekends We recommend the pre set settings shown in the table below they can reduce your heating cooling expenses Set to the time you and the temperature you during the morning until leave for the day Set to the time you leave and the temperature you while you are away usually energy saving level Set to the time you home and the temperature want during the evening until Set to the time you go to bed and the temperature you want overnight an energy saving level Leave and Return periods can be canceled on weekends pm am pm adjust program schedules Press SET CLOCK DAY SCHEDULE SET SCHEDULE Press s or t to set your weekday time Mon then press Press s or t to set the temperature this time period then press NEXT Set time and temperature for the time period Leave Repeat 2 and 3 for each weekday time Press NEXT to set weekend time Sat Sun then press DONE save exit Make sure the thermostat is to the system you want to program or Cool You can press CANCEL PERIOD to unwanted time periods except Clock Day Day Schedule Schedule 62 Tue Wed Thu Fri schedule override temporary s or t to immediately adjust temperature This will temporarily the temperature setting for current time period new temperature will be only until the next time period begins example if you want to turn up heat early in the morning it will be lowered later when leave for the day cancel the temporary setting at time press RUN SCHEDULE Make sure the thermostat is to the system you want to control cool or auto Schedule schedule override permanent HOLD to permanently adjust temperature This will override temperature settings for all time feature turns off the program and allows you to adjust the manually as needed temperature you set will maintained 24 hours a day until manually change it or press RUN to cancel and resume programmed schedule Make sure the thermostat is set the system you want to control heat or auto Schedule changeover heat cool Changeover is a feature used in climates where both air conditioning heating are used on the same day When the system is set to Auto the automatically selects heating or cooling depending on the indoor and cool settings must be at least 3 degrees apart The thermostat will adjust settings to maintain this separation called 3 degree separation between heating and cooling set temperatures is fixed cannot be changed Press system button until screen Clock Day The Auto system setting may appear depending on how your was installed compressor protection can occur if the compressor is too soon after shutdown This forces the compressor to wait for few minutes before restarting the wait time the display will the message Cool On or Heat On you have a heat pump When the safe time has elapsed the message flashing and the compressor turns On Clock Day flashes until safe time has elapsed Intelligent Recovery Intelligent Recovery eliminates guesswork when setting your schedule allows the thermostat to how long your furnace and air conditioner take reach the temperature you want set your program schedule to the time you want the house to reach your temperature The thermostat then turns on the heating or cooling at just right time to reach your scheduled temperature at your scheduled time example Set the Wake time to 6 am and the temperature to 70 The heat come on before 6 am so the temperature is 70 by the time you wake at 6 When Adaptive Intelligent Recovery is in effect the thermostat will display Recovery replacement are optional to provide power if your thermostat wired to run on AC power when fresh batteries immediately when REPLACE BATTERY warning flashing The warning flashes two months before the batteries depleted if the warning does not appear should replace batteries once a or before leaving home for more a month batteries are inserted within two the time and day will not to be reset All other settings are stored in memory and do require battery power and pull to remove Battery fresh AA alkaline then reinstall holder assistance assistance with this product please yourhome honeywell com call Honeywell Customer Care toll at 1 800 468 1502 and pull to remove thermostat over to find number and date code damage hazard prevent possible compressor damage do not operate cooling system outdoor temperature is below 50 10 you have difficulty with your thermostat please try the following suggestions problems can be corrected quickly and easily is Check circuit breaker and reset if necessary Make sure power switch at heating cooling system is cooling does respond Make sure furnace door is closed securely Make sure fresh AA alkaline batteries depending on are correctly installed see page 6 Press SYSTEM button to set system Heat see page 2 sure the temperature is set higher than the Inside Press SYSTEM button to set system to Cool see page 2 sure the temperature is set lower than the Inside Check circuit breaker and reset if necessary Make sure power switch at heating cooling system is Make sure furnace door is closed securely Wait 5 minutes for the system to respond do change sure heating and cooling temperatures are set to ranges Heat 40 to 90 4.5 to 32 Cool 50 to 99 10 to 37 On