Honeywell Pro 3000 Series Installation Manual

File Preview
File Preview
Click below to download for free

File Data

Name honeywell-pro-3000-series-installation-manual-3946812075.pdf
Type PDF
Size 3.98 MB
Downloads

Text Preview

Non Programmable Thermostat Instructions Series installation the wallplate from the by pulling from the bottom follow directions below for Pull wires through wire hole Position wallplate on wall level and hole positions with pencil Drill holes at marked positions as below then tap in supplied anchors Place wallplate over anchors insert tighten mounting screws 3 16 for 7 32 for HERE hole options wires in this factory jumper only two transformer batteries for primary backup power Terminal block C for primary AC power if batteries are installed terminal designations Vac common For 2 transformer use common wire from cooling valve energized in heating Vac power from heating transformer 24 Vac power from cooling valve energized in cooling relay contactor Heat relay Auxiliary heat relay Vac common valve energized in heating Vac power output when set to Em Heat valve energized in cooling relay contactor heat relay conventional and heat pump systems Heat Pump System TH3210D Vac common 3 valve energized in 5 1 output when set to Em Heat 8 valve energized in 5 relay contactor Auxiliary heat relay 9 heat relay 9 Heat Pump System TH3110D 7 Vac common 3 valve energized in 5 joined by jumper Power 1 valve energized in 5 relay contactor 6 joined by jumper Vac common 3 joined by jumper System TH3110D 1 transformer Power 1 relay contactor Heat relay System TH3110D 2 transformers Vac common 3 4 heating transformer 1 2 Power cooling transformer 1 2 Heat relay relay contactor specifications 18 to 22 gauge thermostat wire cable is not required 1 Power supply Provide disconnect means overload protection as required 2 Remove jumper for 2 transformer systems 3 Optional 24 Vac common connection 4 Common connection must come from cool 5 Use either O or B terminals for changeover transformer Only System TH3110D Power 1 Heat relay Vac common 3 joined by jumper Vac common 3 joined by jumper Only System with Fan TH3110D Power 1 relay Heat relay Vac common 3 joined by jumper Only System TH3110D Power 1 relay contactor 6 Use a small piece of wire not supplied to W and Y terminals 7 Set fan operation switch to Heat Pump see 5 and configure system type for heat see page 6 8 L terminal sends a continuous output when is set to Em Heat Connect Honeywell zoning panels to switch the to Emergency Heat field jumper between Aux and E if is no emergency heat relay 9 operation settings TH3110D only or Oil For gas or oil heating leave the fan operation switch this factory set position This setting for systems that control the fan in a for heat or Heat Pump Change the to this setting for heat pump or heat systems This setting is systems that allow the thermostat to the fan in a call for heat if a fan is connected to the G terminal fan operation switch mounting Align the 4 tabs on the wallplate corresponding slots on the of the thermostat Push gently until the thermostat Push excess wire back into the in place opening Plug wall opening with non insulation Setup the procedure below to configure thermostat to match the installed system and customize operation as desired begin press and hold the s and t until the display changes Press t to change settings Press s to advance to next Press and hold ts to exit and settings function 1 System type only options factory settings in bold oil or electric heat with air conditioning pump 5 minute compressor off time in heating and cool 5 Heating cycle rate cycles hour only 6 Auxiliary heat rate CPH only 8 Emergency heat rate CPH only 9 Compressor rate CPH 14 Temperature 15 Compressor gas or oil furnaces of less than 90 efficiency steam or gravity systems hot water systems furnaces of over 90 efficiency electric furnaces cycle rate options 2 4 6 7 8 10 11 or 12 CPH gas or oil furnaces of less than 90 efficiency steam or gravity systems hot water systems furnaces of over 90 efficiency electric furnaces cycle rate options 2 4 6 7 8 10 11 or 12 CPH electric emergency heat steam or gravity systems hot water systems furnaces of over 90 efficiency gas or oil furnaces of less than 90 efficiency cycle rate options 2 4 6 7 8 10 11 or 12 CPH for most compressors cycle rate options 1 2 4 5 or 6 CPH compressor off time options 0 1 2 3 or 4 minute off time Protection Setup Function 15 Forces the compressor to wait a few minutes before to prevent damage During the wait time the message Cool On or Heat On heat pumps will flash on the display system test Set SYSTEM switch to Heat Press t to turn on and check see table below Press t until systems turn off Set SYSTEM switch to Em Heat and steps 2 3 above TH3210D Set SYSTEM switch to Cool and steps 2 3 above Press and hold ts to terminate at any time switch 0 test test 10 Heating system 20 Emergency heat 30 Cooling system 70 Thermostat information reference only status and fan turn off turns on heat turns on TH3210D only and fan turn off and fan turn on heat turns on and fan turn off and fan turn on only Software revision number major revisions Software revision number minor revisions Configuration identification code major Configuration identification code minor Production configuration date code week Production configuration date code year you have difficulty with your thermostat please try the following suggestions problems can be corrected quickly and easily is Check circuit breaker and reset if necessary Make sure power switch at heating cooling system is Make sure furnace door is closed securely Make sure fresh AA alkaline batteries are correctly see page 2 cooling does respond do change Set system switch to Heat Make sure the temperature is higher than the Inside temperature Set system switch to Cool Make sure the temperature is lower than the Inside temperature Wait 5 minutes for the system to respond sure heating and cooling temperatures are set to ranges Heat 40 to 90 4.5 to 32 Cool 50 to 99 10 to 37 On or On is Compressor protection feature is engaged Wait 5 for the system to restart safely without damage the compressor On is displaye

Related Files