Honeywell th8320wf1029 User Manual [PDF]

File Preview
File Preview
Click below to download for free

File Data

Name honeywell-th8320wf1029-user-manual-pdf-3907426851.pdf
Type PDF
Size 1.47 MB
Downloads

Text Preview

System Setup Wi Fi Thermostat TH8320WF thermostat works on 24 volt systems It will NOT work on 120 240 volt systems thermostat contains a Lithium battery which may contain Perchlorate material Material handling may apply www dtsc ca gov hazardouswaste perchlorate NOTICE Do not place your old thermostat in the trash if it contains in a sealed tube Contact the Thermostat Recycling Corporation at www or 1 800 238 8192 for information on how and where to and safely dispose of your old thermostat To avoid possible compressor damage do not run air conditioner if the temperature drops below 50 10 of Contents 2 Functions and Options 3 Setup 3 System Test 7 8 PUMP Designations Terminal Letters 2nd stage compressor contactor 2nd stage heat relay Optional wirer save module Optional outdoor or remote sensor Optional outdoor or remote sensor Cooling power Connect to secondary side cooling system transformer Heating power Connect to secondary side heating system transformer stage heat relay stage compressor contactor relay Common wire from secondary side of transformer if 2 transformers Pump Terminal Letters 2nd stage compressor contactor pump reset powered continuously System is set to Em Heat system when set to Heat Cool or Off Auxiliary Emergency heat relay Optional wirer save module Optional outdoor or remote sensor Optional outdoor or remote sensor Cooling power Connect to secondary side cooling system transformer Heating power Connect to secondary side heating system transformer Changeover valve for heat pumps Common wire from secondary side of stage compressor contactor relay system transformer functions and options can change options for a number of system functions Available functions depend on type of system you have The functions designated with four digit numbers along with options are described on pages 3 thermostat is pre set for a single stage heating cooling system function 0170 for a heat pump will adjust the default settings Press SYSTEM Press and hold the two blank keys on either of the center blank key for approximately seconds until screen changes Cycle through the functions press st next to four digit number on the left As needed change options for any function by st next to the number on the right When you have made all changes press DONE save and exit Options setup Device Name name will the when you it remotely you register thermostats each one a name Office Media Room 52 Thermostat Fireplace Music Room 53 Upper Level Foyer Utility Room Game Room 37 Nursery Walk In Closet Garage Wine Cellar Great Room 39 Office 1 Workshop Guest Room 40 Office 2 Conference Room Gym Dressing Room Kid s Room Meeting Room Kitchen Machine Room Kitchen 1 Kitchen 2 Open Area 1 Laundry Room 46 Sewing Room 69 Open Area 2 Thermostat 1 Basement 2 Bathroom 3 Bathroom 1 4 Bathroom 2 5 Bathroom 3 6 Bedroom 7 Bedroom 1 8 Bedroom 2 9 Bedroom 3 Bedroom 4 Boat House Bonus Room Server 1 Computer Room 30 Library Living Room 48 Storage Room 71 Server 2 Den Dining Room Lower Level Exercise Room 33 Master Bath Master Bed Family Room Pantry Play Room Pool Room Porch Rec Room Studio Sun Room Theater Stock Room Spa Year Setting two digits Year 20xx Year 21xx Year Setting two digits Month Setting i e 2001 i e January Date Setting Schedule Options Program schedule is on 7 day programmable Program schedule is off Thermostat can not be programmed setup Select System you are not sure of heating cooling type or have questions to Options Restore Schedule Continue using programmed schedule Restore thermostat program to energy saving settings Heat cool Gas oil or electric heating with central air conditioning Heat pump Heat pump without backup or auxiliary heat Heat only without fan Gas oil or electric heat without central air Heat only with fan Gas oil or electric heat without central air Heat only no fan Gas oil or hot water heat without central air Cool only Central air conditioning only Heat pump Heat pump with backup or auxiliary heating Heat Cool Multiple stages 2 heat stages wires on W and W2 2 stages wires on Y and Y2 Heat Cool Multiple stages 2 heat stages wires on W and W2 1 stage wire on Y on Y and Y2 Heat Cool Multiple stages 1 heat stage wire on W 2 cooling stages Heat pump multiple stages 2 heat stages wires on W and W2 cooling stages wires on Y and Y2 no aux heat Heat pump multiple stages 3 heat stages wires on W W2 and Aux cooling stages wires on Y and Y2 with aux heat Heat Pump Type Air to air heat pump Geothermal heat pump Heating Fan Gas or oil heat Use this setting if you have a gas or oil heating system controls fan operation Electric heat Use this setting if you have an electric heating system controls fan operation Heat Pump Cooling changeover valve Use this setting if you connected a wire Valve heat pumps to the O B terminal to the O B terminal Heating changeover valve Use this setting if you connected a wire Back up Heat Electric Fossil fuel External Fossil Kit No Yes 1st stage compres cycle rate Recommended for most compressors options 1 2 4 5 or 6 CPH 2nd stage com cycle rate Heating Cycle Heating Cycle Stage 2 Heating Cycle Stage 3 Backlight Gas or oil furnace Standard gas oil furnace less than 90 efficiency Electric furnace Electric heating systems Hot water or high efficiency furnace Hot water system or gas furnace than 90 efficiency Gas oil steam or gravity system Steam or gravity heat systems options 2,4,6,7,8,10,11,12 Backlight off then on for approximately 8 seconds after keypress Backlight always on low intensity full bright after keypress setup Options Manual Auto Manual changeover Heat Cool Off Automatic changeover Heat Cool Auto Off Automatically turns on Heat Cool based on room temperature Note System maintains minimum difference between heat and cool settings Auto changeover Heat cool temperature 3 apart 1.5 options 2 9 2 to 9 to 5 Temperature For Fahrenheit Celsius Automatic Daylight Time Ad Off On Remote Temp Dual Fuel Heat Upstage to Timer None Outdoor for Display Outdoor for Control Remote Indoor Disabled 30 minutes 60 minutes 1.5 hours 2 hours 3 hours 4 hours 5 hours 6 hours 8 hours 10 hours 12 hours 14 hours 16 hours Droop Temperature State 1.0 options displayed in or Backup Heat Droop Tem Comfort Off Economy Heat Pump Com Lockout Off options displayed in or Heat Pump Aux None options displayed in or Filter Change reminder after number of run time not time Off no

Related Files