Honeywell Thermostat Q682 User Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | honeywell-thermostat-q682-user-manual-1890523647.pdf |
---|---|
Type | |
Size | 973.75 KB |
Downloads |
Text Preview
T8190A 191108AJ Q682 or Cooling and Wallplate Heating Cooling and Subbase Rev 9 94 Inc 1994 Form Number 69 0643 the world of energy savings with your new thermostat The Honeywell name is assurance of accurate control and reliable for years to come new thermostat will automatically lower raise the temperature in your home one or times every 24 hours This allows you to lower your fuel costs while awaken or returning home to a comfortable this manual to learn how to use your thermostat Notice control contains mercury in a sealed Do not place control in the trash at the end its useful life this control is replacing a control that mercury in a sealed tube do not place old control in the trash your local waste management for instructions regarding recycling and proper disposal of this control or of an old containing mercury in a sealed tube of Contents of Your Thermostat 4 the Temperature 7 Timer Batteries 8 the Timer 9 10 Subbase Switches 13 14 the Thermostat 22 Rate Adjustment 22 Adjustment 23 27 Of Your FLIP UP COVER Lift it up to set clock for saving and normal temperature THERMOSTAT COVER Lift up and remove adjust heat anticipator THERMOMETER Provides accurate room reading TEMPERATURE SETTING LEVERS Left mark controls the low temperature red mark controls the high tempera TIMER This timer provides a 24 hour dial to hold the programming pins TIMER SETTING KNOB Turn clockwise match the correct AM or PM time to time indicator TIME INDICATOR Arrow head triangle indicates low blue temperature or high red temperature setting in on program index wheel Also time on 24 hour dial PROGRAM INDEX WHEEL Controls high low temperature at specific time of day set by program pins PROGRAM PINS Must be inserted into 24 timer dial slots to control program wheel PIN SLOTS Located on 24 hour dial at 10 intervals for program pin insertion PROGRAM DIAL 24 hour dial with light to indicate daytime and dark band to nighttime HEAT ANTICIPATOR SCALEPLATE to match the heating system draw in amperes ANTICIPATOR SETTING LEVER Must be to match the heating system control current MERCURY BULB AND BIMETAL ELE 2 Provide automatic temperature by switching the heating or cooling on or off WALLPLATE Included with thermostat mounting base and wiring for heating only or cooling only SUBBASE Optional not included with ordered separately Provides base wiring connections and switching control for heating cooling See Setting Subbase Switches for additional information 719 the Temperature Heating Set the left lever blue mark to the energy temperature you want when you are or your home is unoccupied Set the right lever red mark to the tempera you want for normal comfort periods You may override the time program by both the red and blue levers to the temperature setpoint Cooling Set the left lever blue mark to the tempera you want for normal comfort periods Set the right lever red mark to the energy temperature you want when you are or your home is unoccupied TEMPERATURE LEVER 60 70 80 1 high and low temperature levers Timer Batteries is supplied to the timer by the 24 Vac by two AAA alkaline batteries or by the heating or cooling control Backup batteries may be installed to power to the timer if power is interrupted using a 24 Vac powering method Install in thermostat as shown in Fig 2 Once year or when batteries are dead replace with new AAA alkaline batteries We recommend batteries Properly dispose of old LOCATION FOR AAA BATTERIES WITH POSITIVE UP 2 timer batteries the Timer thermostat flip up cover and you find the program dial slotted in 10 minute Adjust the timer to the current by carefully turning the knob clockwise DO NOT reverse the knob When time is correctly set the time indicator triangle shape will point to the correct and corresponding daytime light or dark band of the program dial Fig 3 For 11 PM the time indicator arrow point directly to the dark band For 11 the arrow will point to the light band Saving Time Daylight Saving Time starts move the carefully in a clockwise direction one When Daylight Saving Time ends move knob carefully in a clockwise direction 23 Do NOT reverse the knob or damage to mechanism may occur DIAL 6 INDICATOR ARROW 821 3 the timer PROGRAM DIAL AREA FOR NIGHT SETTINGS can program your thermostat to automati lower and raise the temperature one or times every 24 hours depending on the of program pins used setting your program the slots on the program dial Fig 4 dial is slotted for the program pins that can inserted at 10 minute intervals thermostat flip up cover and you will find 24 hour program dial The slots on the dial Fig 4 are for the program pins can be inserted at 10 minute intervals red and three blue program pins are with your thermostat The red pins the high temperature period the blue start the low temperature period A program has been preprogrammed A pin is inserted at 6 00 AM for high SLOT INDEX WHEEL INDICATOR ARROW STORAGE 4 components comfort period a blue pin is at 10 00 PM for low temperature saving period Two additional sets of are located in the program pin storage You can set up to six temperature with the pins supplied We recom at least five hours for each energy period change the pins or add a new energy period To insert a pin push it straight into the notch on the program dial until it is seated To remove a pin press against the dial and pull the pin straight out NOT attempt to change a pin if it is with the program index wheel On heating cooling systems set the switches to desired positions See Subbase Switches section