Honeywell Thermostat T410 User Manual

File Preview
File Preview
Click below to download for free

File Data

Name honeywell-thermostat-t410-user-manual-7204519386.pdf
Type PDF
Size 699.42 KB
Downloads

Text Preview

T410A provides single line break provides double line break Range 40 to 80 4 to 27 Ratings 60 Hz noninductive at 120 240 Vac 19A at 277 Vac models Honeywell Thermostat new Honeywell T410 Electric Heating Thermostat line voltage control of a radiant cable electric and resistive rated fan forced heaters within ratings listed above thermostat is a line voltage control 120 Volts to Volts Do not install it if you are not completely with house wiring If handled improperly can be risk of a 120 Volt to 240 Volt electric hazard which may cause serious injury or NOTICE this control is replacing a control that contains in a sealed tube do not place you old in the trash Dispose of properly you local waste management authority for regarding recycling and the proper of a old control Voltage Heat Thermostats INSTRUCTIONS PREPARATION installation of your Honeywell thermostat will if you follow these instructions STEP BY It is recommended that as you read understand complete each step you check it off with pencil or thermostat suitability for your home system reviewing the ratings listed above certain that your heating system is working if it has been inoperative for a length of If the system does not work contact your local for assistance unpack your new thermostat To avoid to the sensing element do NOT remove thermostat cover until wiring has been completed packages of screws instructions receipt and REMOVE OLD THERMOSTAT by turning off power to the heating circuit at main service panel cover of old thermostat normally off when pulled firmly from the bottom If it check for a screw that locks the cover screws holding thermostat base to outlet box lift away wires from old thermostat As you each wire tape the end and label it with letter of the terminal designation to make reconnection new thermostat easier the old insulation for cracks nicks or fraying apply high quality plastic tape where necessary adequate insulation the old thermostat for reference purposes until your new thermostat is functioning Registered Trademark 2002 Honeywell All Rights Reserved UL LINE VOLTAGE ELECTRIC HEAT THERMOSTATS WIRE AND MOUNT NEW THERMOSTAT CHECK OUT THERMOSTAT thermostat cover by grasping the top and ends with fingers and pulling outward wires to the thermostat as shown in the wiring diagram Push the wires into the box and insert the thermostat into the box for by pushing against top and bottom of the base Do not press on setting knob on the power to the heating system setting knob all the way clockwise listen clicking sound as switch makes contact Electric should begin operation knob all the way counterclockwise listen clicking sound as switch breaks contact Electric should shut off the thermostat to the box with the two captive screws provided SETTING THERMOSTAT thermostat cover knob to desired room temperature Rough handling or strong pressure can knob or sensing element and change with setting knob at 70 20 on the scale this setting is not satisfactory after at least two of operation turn setting knob upscale to the temperature or downscale to lower the tempera Move knob only a degree each time SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD AS REQUIRED ON POSITIVE OFF UNUSED LEADWIRES TO BE PROPERLY INSULATED ACTIVATED ON TEMPERATURE MAKES ON TEMPERATURE FALL SERVICE CO ALR SOLDERLESS CONNECTORS MUST USED WHEN CONNECTING WITH ALUMINUM CONDUCTORS A FIRE HAZARD CAN RESULT LINE VOLTAGE ELECTRIC HEAT THERMOSTATS Honeywell thermostat requires little or no attention Most problems can generally be traced to the following heat should start to warm up within two minutes If not qualified electrician to check thermostat and heater TROUBLESHOOTING sure power is on at service panel Turn temperature setting fully clockwise connections to temperature setting fully affected by or radiant heat never turns setting thermometer disagree power to circuit OFF tighten all wiring connections any frayed or broken wires a qualified electrician for assistance should start to cool within minutes If not turn off at the main service panel and contact qualified electrician to change the location The thermostat be about 5 ft 1.5m above the floor and on an wall warrants this product to be free from defects in the workmanship or materials under normal use and service for period of one 1 year from the date of purchase by the consumer If at any time during the warranty period the product is or malfunctions Honeywell shall repair or replace it at Honeywell option within a reasonable period of time One Year Warranty the product is defective it with a bill of sale or other dated proof of purchase to the hardware or home center store where you purchased or package it carefully along with proof of purchase including date of purchase and a short description of the malfunc and mail it postage prepaid to the following address Return Goods 4 MN10 3860 Douglas Dr N Valley MN 55422 Canada Honeywell Limited Honeywell Limitee Dynamic Dr Ontario M1V 4Z9 warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the of malfunction was caused by damage which occurred while the product was in the possession of a consumer sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IM OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion of incidental or consequen damages so this limitation may not apply to you WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PAR PURPOSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not limitations on how long an implied warranty lasts so the above limitation may not apply to your warranty gives you specific legal rights and you may have other rights which vary from state to state you have any questions concerning this warranty please write to Honeywell Customer Relations 1985 Douglas Dr N Golden Valley MN 55422 In Canada write Retail Products ON15 02H Honeywell Limited Honeywell Limitee Dynamic Dr Scarborough Ontario M1V 4Z9 and Control Solutions International Inc Honeywell Limited Limit Douglas Drive North Valley MN 55422 Dynamic Drive Ontario M1V 4Z9 G H 2 02

Related Files