MV100 Electric Controllers T200 Thermostatic Controllers V2000 Radiator Valves CONTROLS BODIES DATA MV100 T100 T200 Controllers when paired with V2000 Valves provide automatic temperature control by the flow of steam or hot water through free radiators convectors and other heating units They comfort and energy savings at affordable prices Continually monitors and adjusts room temperature consistent comfort and relief from underheating overheating T100 T200 Controllers include sensor setpoint dial valve actuator components can be integral or by capillary tubing T100 T200 Controllers require no electrical T100A F M models have range limiting features to limit or lock at a fixed setting can require limit accessory EPDM valve seat disk assures tight shutoff on steam hot water systems Nickel plated bronze cast valve body Cartridge containing all working parts inserts into body for ease of service Cartridges are replaceable while valves remain in and under pressurE WITH accessory service MT100C Valves remain normally open with no control mounted Valves can be used with T100 T200 Thermostatic or Electric Controllers Information MV100 only and Adjustments Steam Applications 10 12 Valve Cartridge Replacement 13 ELECTRIC CONTROLLERS T100 T200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR VALVES Electric Controller See Fig 1 Industrial grade plastics with low thermal conductivity Ring Plated brass Parts Brass thermostat capsule other metals element Wax filled brass capsule Ratings Type Spst switch 24 Vac 60 Hz or 24 Vdc Consumption 0.125A 3W Switch Low voltage 24 Vac 5A two position spst open switch closes when controller powered with Controller Mounted closed valve remains closed without power Normally open model available in Canada Time at 78 cid 176 F Maximum 5 minutes from cold to open Temperature Rating Maximum 122 cid 176 F 50 cid 176 C Thermostatic Controllers See Table 1 See Fig 1 Self powered no electrical connections Sensor setpoint dial and valve actuator Industrial grade plastic with low thermal conductivity Ring Plated brass Parts Brass thermostat capsule other metals Element Wax Liquid Ethyl Acetate non toxic Ratings 43 cid 176 F to 79 cid 176 F 6 cid 176 C to 26 cid 176 C 125 52 Valves See Table 2 See Fig 2 and 3 Bronze 1 2 in Brass Brass Seal Double EPDM seal Brass and stainless steel with EPDM seat disk Apply 25 ft lb 30 N cid 149 m torque when installing the cartridge Temperature Rating 266 cid 176 F 130 cid 176 C Pressure Ratings 145 psi 10 bar 15 psi 103 kPa MV100 Controller 36 psi 248 kPa T100 or T200 Controller 14.5 psi 1 bar Low Noise 2.9 psi 20 kPa 1 8 in 1 2 in 3 4 in 1 2 in 3 4 in and 1 in INFORMATION purchasing replacement and modernization products from your TRADELINE wholesaler or distributor refer to the Catalog or price sheets for complete ordering number you have additional questions need further information or would like to comment on our products or services please write or Your local Honeywell Automation and Control Products Sales Office check white pages of your phone directory Honeywell Customer Care Douglas Drive North Minnesota 55422 4386 Canada cid 151 Honeywell Limited Honeywell Limit 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Sales and Service Offices in all principal cities of the world Manufacturing in Australia Canada Finland France Japan Mexico Netherlands Spain Taiwan United Kingdom U S A ELECTRIC CONTROLLERS T100 T200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR VALVES 25 54 TUBE LENGTH FT 1.4 m 54 75 TUBE 4 1 2 FT 1.4 m TUBE LENGTH FT 2m OR 16 FT 5m 54 54 50 TUBE 6 1 2 FT 2 m 75 20 74 51 1 MV100 T100 and T200 dimensions in in mm ELECTRIC CONTROLLERS T100 T200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR VALVES Range are in one unit 1 T100 T200 Models 6 1 2 ft 2 m 16 ft 5 m 4 1 2 ft m 6 1 2 ft 2 m Sensor is remote from combination setpoint dial and valve and setpoint dial combined and remote from valve mount remotely from each other to 79 cid 176 F to 26 cid 176 C to 79 cid 176 F to 26 cid 176 C to 79 cid 176 F to 26 cid 176 C with Mount the unit horizontally on the valve body for accurate temperature regulation are in one tamper resistant unit body with chrome plated end 2 V2000 Models Pattern Angle Nut with Threaded Sweat in NPT 1 8 in NPT for Vent where manual valves were not originally installed used with remote temperature sensing controllers used with direct mount controllers T100A M T200A with copper tubing installations in single pipe steam applications Straight Body Angle Body MAX Horizontal Angle Body MAX Straight Body MAX MAX Refer to Table 3 for detailed valve dimensions for each valve size 2 V2000 dimensions ELECTRIC CONTROLLERS T100 T200 THERMOSTATIC CONTROLLERS AND V2000 RADIATOR VALVES in 1 2 1 2 1 2 3 Valve Dimensions in mm Maxa 26 in in mm in in mm 95 104 cid 151 106 4 1 16 104 cid 151 114 cid 151 114 98 58 66 98 1 1 8 29 74 4 5 16 110 1 5 16 34 115 54 28 64 132 1 3 16 31 74 5 3 16 132 1 7 16 37 66 104 cid 151 74 4 1 16 104 cid 151 43 3 13 16 98 1 3 16 31 1 2 3 8 Max dimension is with T100A control installed except for V2042H for which it is without the steam air vent Available threaded 1 2 in and 3 4 in only Available nut with threaded tailpiece 1 2 in and 3 4 in only nut with sweat tailpiece 1 2 in and 3 4 in only gpm at 1 psi drop across fully open valve Btu hr at 7 psi drop

Related Files