Invensys MPC-2PO Multi-Purpose Pneumatic Output Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | invensys-mpc-2po-multi-purpose-pneumatic-output-module-5378429061.pdf |
---|---|
Type | |
Size | 1.20 MB |
Downloads |
Text Preview
MPC 2P0 Controller Output Module U S A OF CONTENTS GUIDELINES THIS PACKAGE COMPONENTS REQUIREMENTS AND SETUP INFORMATION Outputs SCALE and OFSET Using MOCALC LEDs pneumatic output module MPC 2PO an module that plugs directly into any of four option slots available on the MicroSmart controller MSC MPC providing output capability to the MSC MPC for use in packaged unit control and HVAC applications the MPC 2P0 two pneumatic outputs to directly drive damper and valve actuators in building systems NO MPC 2P0 LISTINGS UL W 6 Energy Equipment UL 873 Indicating and Regulatlng pending UL 664 Smoke Control Sub assembly Complies with FCC ass requirements as a smoke control system sub assembly to be used by itself or as part of a MicroSmart Network RCM NCM in a smoke control For smokecontrol applications install accordance with F 25645 Smoke Systems Manual TWO 3 15 psig pneumatic output 8 SCFH 15 psig CONSUMPTION Application dependent not a constant bleed device AIR 30 psig maximum 2 0.05 psi FILTRATION 25 micron ENVIRONMENT 32 to 122 F to 50 C 5 65 RH not condensing REQUIREMENTS MPC 2P0 derives operating power from associated MSGMPC 5 x 6.25 Net 12 1 2 oz 13 oz GUIDELINES equipment has been tested and found to with the limits for a Class digital pursuant to Part 15 of the FCC rules limits are designed to provide reasonable against harmful interferente when the is operated in a commercial This equipment generates uses can radiate radio frequency energy and if not and used in accordance with the manual may cause harmful to radio communications of this equipment in a residential area likely to cause harmful interferente the user will be required to correct the at his own expense which Guidelines TO CONTROLLER r 0 WITTxB C PL INSTALLING THE MPG2P0 BE SURE THAT THE CONTROLLER FULLY SEATED TO THE BACKPLATE BEFORE AND AFTER THE IS FASTENED TO THE ENCLOSURE MPC 2P0 Output Module 1 Installation Guidelines reduce risk of fire or electrical shock install in controlled environment relatively free of inspect the unit for any beginning the installation process for the defects and to make sure all parts are any flaws are detected contact your local Siebe or authorized represbntative immediately information is contained in this For further details regarding software please refer to the appropriate Guide and the MicroSmart Operator User Guide IN THIS PACKAGE MPG2PO module is supplied with one 148 MPG2PO module circuit board COMPONENTS MPG2PO MSC MPC Multi purpose controller direct connection to a an assembly that fits into any of MPG2PO four option slots on the MSGMPC To remove power from the MSGMPC and the MPG2PO the desired option slot the MSGMPC Wiring instructions and assignments are provided below MPG2P0 be sure that the installin is fu ii y seated to the backplate before after the backplate is fastened to the INSTRUCTIONS AND INFORMATION Outputs power from the MSGMPC main air to the MPG2PO black 30 psig maximum connected to the air supplied to the MPG2PO must be oi free and filtered by a 25 micron filter REQUIREMENTS MPC 2P0 module is powered by the on which it is installed power supply from associated controller before installing damage not attempt to power the unit ON until is complete prevent electrical shock and the the output tubing larger tubes from the MPG2PO or valve being controlled the drain tube smaller tube clear so that any liquid in the system will away from the controller the MPG2PO one of the four slots on the MSGMPC controller input power to the MSC MPC table below illustrates the numbering scheme the two pneumatic outputs When making assignments the first entry is the option slot on the connected MSGMPC controller the second entry is the number of the output being used example when plugged into option slot 2 pneumatic output number 1 has an of 21 Guidelines NUMBER SLOT ADDRESS 01 and Software Assignments Pneumat Outputs 1 SCALE and OFSET Using comes standard with the DOS Tool and is used to determine the values for SCALE and OFSET when with the desired values to be displayed given input parameters MOCALC is typically to calibrate the display in engineering units accordance with measurements taken In cases it can be used to correct for tolerance in input or output readings use MOCALC severa1 parameters must be prior to running the program First the property to be measured or controlled is near the high end of its scale and the bit value is recorded Then another is taken with the property at the Iow end its scale and the bit value displayed by the is again recorded Once this information determined the MOCALC program is able to the appropriate values for SCALE and Note that the characteristics of the must be linear to use MOCALC sample calculations below are for a Belimo Actuator with the P500 feedback option will be used to control a valve from 0 to 1 OO open the point to be calibrated set OFSET 0 and 4096 feedback wired drive the actuator valve fully 100 Record the measured bit value by the system for this point This is the high value Next drive the actuatorhlalve fully 0 Record the measured bit value This is the low value are now ready to execute the MOCALC From the C U CM directory type and press ENTER At the Enter Number prompt type 1 to Formulas for Scale and Ofset At the Enter Number prompt type 6 to Formulas for Bit High Bit Low program prompts you for the device range and range low values These values are the of the point