Invensys MSC-P1500 Input-Output

File Preview
File Preview
Click below to download for free

File Data

Name invensys-msc-p1500-input-output-1508429763.pdf
Type PDF
Size 1.86 MB
Downloads

Text Preview

lnvensys Building Systems Building Systems Inc Clifford Avenue Clifford Avenue Zip 61111 Box 2940 Box 2940 Park IL 61132 2940 Park IL 61132 2940 States of America Packaged Unit Controller MicroSmartTM MSC P1500 Series Input Output Unit Controllers are for use with heat pump ventilator coils and similar applications 6 analog compatible MSC PI500 1000 ohm Balco and 1000 ohm platinum series temperature sensors Two of the 6 analog configurable as 4 to 20 mA or 0.5 to IO Vdc inputs a supervision may be as a status contact any analog dedicated contact equipment status or as pulse type inputs can be used for outputs actuators Triac outputs can be controller also provides solid state start stop control and staging control or for 24 Vat separately with pulse width type actuators Two to 20 mA analog outputs are available use with actuators and MSC P1504 RJ 11 communications controller with the MSC IS series sensor which can remote digital display of temperature set and allow selective overrides is MSC PI 500 can be installed as a networked or as a stand alone controller For stand operation models offer a real time clock pre installed used stand alone communications Handheld Operator A portable PC used in conjunction with Laptop Interface Module MSC LIM can also pro communications the model chart below the controller used with the network communications pair RS 485 MicroSmart via a Chart Chart in U S A the MSC PI500 controller DMS350A DMS 35 350A DCMs DCM 1000 11 O or later Firmware Software Version Operator Facility Management System FMS 11 11 O NC NCM FLASH or later 11 O or later 11 O or later 1 O or later defines compatibility Device Compatibility MSC NCM Configuration Tool Documentation Applicable Documentation 6 Series Sheet Manual Reference features controller benefits and specifications of the point programming controllers using the MicroSmarl DOS Configuration Tool DCT or the DMS Operator MicroSmart portion of controller MCN products system architecture DCT and operation and configuration of Sensor Guidelines installation wiring and basic set up of the series intelligent sensor 3 Sensor Manual programming series intelligent sensor and basic operations of the Application detailed pre engineered controllers MSCP1500 Consulting Engineers Owners Specifying Engineers Sales Personnel Application Engineers Start up Technicians Service Personnel Application Engineers Start up Technicians Service Personnel Application Engineers Start up Technicians Service Personnel Owners Application Engineers Start up Technicians Service Personnel Application Engineers Start up Technicians Service Personnel Sales Personnel MSC P1500 packaged one container the carton for possible damage the components damaged notify the appropriate carrier obvious damage Return damaged products for wiring terminals and mounting hardware wiring diagrams not provided Appropriate Wrist grounding strap 2 power transformer supplying a nominal 24 Vat 20.4 to 30 Vat with a rating up 1OlVA controller with maximum hardware Real Time Clock option for MSC P1500 or equivalent NEMA Type 1 enclosure at 50 60 Hz not provided nuts or 8 pan head screws as appropriate must be a qualified experienced not provided provided provided I N406 032 End of line module the last physical controller on the trunk only provided Two 22.1D and two lOOKa resistors provided configuring Al5 and A16 Electrical shock hazard Disconnect power before installation prevent electrical shock equipment damage Make all connections accordance with the electrical wiring diagram and in accordance national and local electrical codes Use copper conductors are suitable for 75 electronic components The charges produce voltages high enough to damage and associated circuitry within the MSC P1500 are extremely sensitive static discharge Follow static electricity precautions when installing servicing or oper the system in a static free area any static electricity you may have accumulated Discharge static electricity by a known securely grounded object a wrist strap when handling the MSCP1500 The wrist strap clamp must be secured earth ground Communications Commission equipment has been tested and found to comply with the limits for a Class A digital pursuant Part 15 of the FCC Rules These limits are designed protection against harmful interference when the equipment environment This equipment generates uses and can radiate radio energy and if not installed and used in accordance with the instruction may cause harmful interference will be required a residential area is likely to cause harmful interference correct the interference at his own expense radio communications Operation of this provide operated which case the a Department of Communications digital apparatus does not exceed the Class A limits for radio noise emissions apparatus set out in the radio interference Communications of the Canadian Department the MSCP1500 meet UL requirements a grounded ENCL 100 or an equivalent NEMA Type 1 enclosure Avoid locations where excessive moisture corrosive are present This location should be protected and other adverse conditions explosive vapors or wind weather direct Avoid electrical noise interference Do not install near large contractors electrical welding equipment or other electrical noise producing devices MSCP1500 are intended use only where ambient do not 122 50 or fall below 32 OX and relative humidity does not exceed 85 fall below 5 non condensing reduce the risk of fire or electrical shock install in a controlled environment of all contaminants I a the enclosure to be used recommended ENCL 100 not provided Position the MSC P1500 the enclosure as desired Secure the MSC P1500 the enclosure using th

Related Files