Health Care Call System Power Supply 6652 6851 Jeron Cat 6652 6851 Sup Power Supply furnishes DC voltage when the Call System Main Control capacity is exceeded by demand of the number of stations connected to the Control Battery Backup Available Continuous Diagnostic Self Test Current Limited Supplementary Power Supply from an internal 28 VDC power supply built in self charging battery 6851 only provides auto transfer if the building power Normal system on battery is retained for five to minutes depending on the Call System being used power supply is protected system wiring overloads short circuits Recovery from conditions is automatic upon of the overload transient suppressors filter the power surges and noise Power Supplies pro additional power for systems many remote stations Refer the table on the reverse side of datasheet to determine when system will require a Power Supply separate central equipment is required for each Power Supply Data H x W x D 6888 Enclosure x 18 x 4 in x 46 x 10 cm Power Combination ON OFF and 2A circuit breaker Power 6851 only ON OFF switch and circuit breaker Output VDC 100 VA Current Limited Power to 132 VAC 60 Hz 1.5 A Duty Cycle Suppression Two MOV operating Temperature Range to 120 F 0 to 50 C Range 0 to 85 Backup 6851 only operation for five to fifteen depending on system Diagnostics Fault red LED indicator lbs 29 kg 1069 Listed Standard NO 125 Jeron Cat 6888 Central Equipment required continued on next page JERON Electronic Systems Inc cid 132 1743 55 W Rosehill Drive cid 132 Chicago IL 60660 3921 275 1900 cid 132 USA Canada 800 621 1903 cid 132 Fax 773 275 0283 www jeron com cid 132 E mail sales jeron com Power Supply Cat 6652 6851 SUPPLEMENTARY POWER SUPPLY REQUIRED IF TYPE SYSTEM PARAMETERS 100 128 100 or Less MASTER TYPE Bus StationsBus Stations Supplementary Power Supply if number of Master Stations exceeds on the above bus station quantity 680 Patient Stations with of Type 65 Masters Only Patient Stations with of Type 75 Masters Only Type 75 or 65 Masters Muting Patient Stations with of Type 65 Masters Only Muting Patient Stations with 4 of 75 And Type Masters of Type 75 Masters Only Patient Stations with of Type 65 Masters 2 1 of Type 75 Masters 4 8 4 8 12 1 12 Muting Patient Stations with of Type 65 Masters of Type 75 Masters 3 2 1 4 8 12 TYPE SYSTEM PARAMETERS 640 COMBINATION 96 ROOMS PER MAIN CONTROL 610 THAN 140 ROOMS AND FOUR 6165 MASTERS THAN ONE 6165 NURSE CONSOLE AND 192 ROOMS Calculations assume maximum of 10 of call on system simultaneously SUBJECT TO CHANGE WITHOUT NOTIFICATION JERON Electronic Systems Inc cid 132 1743 55 W Rosehill Drive cid 132 Chicago IL 60660 3921 275 1900 cid 132 USA Canada 800 621 1903 cid 132 Fax 773 275 0283 www jeron com cid 132 E mail sales jeron com