Jeron 6807+ 081709
File Preview
Click below to download for free
Click below to download for free
File Data
Name | jeron-6807-081709-0586134297.pdf |
---|---|
Type | |
Size | 809.49 KB |
Downloads |
Text Preview
Health Care Call System Corridor Zone Light 6807 Data Flame retardant UL 94 5VA 2 gang PC ABS blend enclo box Two gang box with two gang trim ring or one gang trim Refer to Installation Manual Ultra bright LEDs capable of up to eight different colors 8 LEDs total two per segment H x W x D 4.8 x 4.9 x 3.7 in 12.1 x 12.4 x 9.3 cm Rating 28VDC 1.4W Connectors Two 2 Cat 5 RJ 45 connectors 7 position Compatibility Provider 680 Ver E 06 or greater order specify 6807 UL 1069 Listed C UL Canadian Standard C22.2 NO 125 Large dome lens for high visibility in long Over forty combinations of color and light Left and right bed color distinction Long life multi color LEDS for maintenance free wiring Fully supervised device to simplify service and Plug in junction for corridor Cat 5 cables for Aesthetically clean design with integrated lens no visible fasteners Model 6807 Prism Zone Lights are used on the 680 Nurse Call Systems to provide visual call signals a certain zone area where patient room dome lights not be visible call placed within the zone area on the system activates appropriate LEDS of the associated zone light The Prism Light LEDs duplicate the preprogrammed colors and patterns of the prism dome lights The ultra bright LED provide over 40 distinct color and flashing pat to uniquely identify any call priority For any call type four light segments are used for clarity Each of the four light segments can indicate up to eight colors white yellow orange green blue magenta and pink with to five light patterns steady slow flash fast flash slow and sequence fast The Prism Zone Light and light pattern changes to indicate the highest pri call currently active within the zone area The large lens is highly visible in long corridors Zone Lights utilize multiple long life light emitting LEDs readily visible from 180 degrees through the translucent lens They are furnished on a two PC ABS flame retardant enclosure for flush wall on either a 1 gang or 2 gang opening The snaps on to mounting panel with no visible fas The Zone Light assembly resists common hospital agents connections utilize standard RJ 45 for Cat 5 5e 6 between dome zone lights The zone light is contin supervised to both simplify service and troubleshoot while ensuring the system is always operational JERON Electronic Systems Inc cid 132 1743 55 W Rosehill Drive cid 132 Chicago IL 60660 3921 275 1900 cid 132 USA Canada 800 621 1903 cid 132 Fax 773 275 0283 www jeron com cid 132 E mail sales jeron com SUBJECT TO CHANGE WITHOUT NOTIFICATION and Provider are trademarks of Jeron Electronic Systems Inc