Jeron 6865+

File Preview
File Preview
Click below to download for free

File Data

Name jeron-6865-2846790531.pdf
Type PDF
Size 1.03 MB
Downloads

Text Preview

Health Care Call System Nurse Console 6865 the handset automatically answers the highest priority longest waiting call displayed at the Nurse Console Calls be answered in any order by selecting one of the up to displayed calls in the in view After selecting a dis call the room audio will be heard on the console Press the Talk touchpoint or for semi private conver lift the handset Dialing the room number from the keypad and pressing Enter will originate a call to room bed Two Volume touchpoints adjust the audio received by the Nurse Master Console at the handset console speaker the Nurse Console staff can page rooms monitor set nurse or aide service requirements locate and dis staff members locate staff by name with optional real locating integration review outstanding service require review staff locations review modify bed status priva or call priority set staff follow tones swing rooms unit and console to console intercom The NURSE or AIDE may be pressed to signal for staff assistance and on with Staff Presence Stations simultaneously activate staff locator and on systems equipped with pocket transmit call messages to assigned pagers Embedded technology designed for continuous operation 5.7 LCD touchscreen display with long life LED Simultaneous display of up to 128 calls or room bed indications Touchscreen menu driven navigation with English prompts Tactile buttons for the most common operations Call in tone mute and tone level adjustment Choice of handset or push to talk communication CAT 5E 6 connection cables Continuous self diagnostics and alerting of console or failure Minimal desktop footprint design with wall mount option Jeron model 6865 Touchscreen Nurse Console is on the Provider 680 Nurse Call System as the pri interface for users of the system Nurse Consoles typically located in areas where staff congregate need to communicate with patients and fellow members Nurse Console may be configured to annunci calls from a specific area an entire unit across units or throughout an entire facility The Nurse graphically displays incoming calls including or staff station calling room number bed if and call priority In the out mode to one hundred and twenty eight calls may be dis simultaneously and in the in mode up six calls may be displayed simultaneously The dis mode may be selected with the IN OUT button highest priority call is always displayed at the top the screen An audible alert tone routine urgent or code sounds for the highest priority queued at the Nurse Console Tones may be with the MUTE button Muted call tones will automatically after a preprogrammed period or after the receipt of another call JERON Electronic Systems Inc cid 132 1743 55 W Rosehill Drive cid 132 Chicago IL 60660 3921 275 1900 cid 132 USA Canada 800 621 1903 cid 132 Fax 773 275 0283 www jeron com cid 132 E mail sales jeron com ensure system availability the Nurse Console is con supervised for any problems Should any Console or any patient or staff device including lights patient stations staff stations or code sta fail a supervision alert indicating the affected or station and an alert tone will annunciate at Nurse Consoles and optionally pocket technicians detailing the issue Console includes a base for setting on a counter and can also be wall mounted using an optional The Console is molded using a flame retardant plastic with a sealed surface designed for cleaning and is impervious to common hospital agents Care Call System Nurse Console 6865 Data Flame retardant UL 94 5VA PC ABS blended with metal base H x W x D 8.3 x 9.2 x 3.0 in 21 x 24.1 x 7.6 cm desk mount footprint 75.9 in 489 cm Long life LED backlit 5.7 14.5 cm 320 x 240 touchscreen screen touchpoints 16 total 0 1 2N 3 4W 5 6E 8S 9 A B C D Vol Up Vol DN keys 7 total Clear Enter In Out Menu Mute Aide Buttons Spill proof polycarbonate membrane type High impact molded ABS with modular cord electret microphone 2.75 7 CM 8 Ohm Electret 2 RJ45 Rating 28 VDC 0.1 A 9704 adaptor wall mount bracket Model 9769 wall jack Model 6869 order specify 6865 SUBJECT TO CHANGE WITHOUT NOTIFICATION JERON Electronic Systems Inc cid 132 1743 55 W Rosehill Drive cid 132 Chicago IL 60660 3921 275 1900 cid 132 USA Canada 800 621 1903 cid 132 Fax 773 275 0283 www jeron com cid 132 E mail sales jeron com

Related Files