FANs 689.1 635 Bulletin Date Supervisory Controller N30 Supervisory Controller is an economical controller designed to monitor and Heating Ventilating and Air HVAC equipment as well as lighting and building access The N30 efficiently the networking of Application Specific ASCs and provides building features including time scheduling management controller data exchange management and remote communications operates at peak efficiency while optimum occupant comfort personnel can review the system status modify control parameters for the Supervisory Controller and its associated using a VT100 Terminal VT100 Terminal or an M Series Workstation the addition of a network card multiple N30s over an Ethernet peer to peer providing increased functionality for more systems 1 N30 Supervisory Controller and Benefits Built in Energy Features Network wide Interlocking Peer to Peer Dial In Dial Out advanced environmental controls for cost savings integrated control between controllers for efficient operation a network card provides direct between devices using protocol access to from remote sites to ensure operation Single Seat User Interface operator to review entire system for and simple access to system data Password Protection secure user access to system 2001 Johnson Controls Inc No LIT 6891050 Workstation Computer VT100 Emulator Air Volume Controller Air Volume Assembly Handling Unit 2 N30 Support of N2 Devices Applications network controllers contain their own so each controller can perform The breadth of this HVAC controller is unparalleled in the industry Device Support N2 Bus is a local communications network links HVAC controllers within the facility proven communication network the N2 Bus is accepted by HVAC control suppliers the N2 system is easy and economical only simple wire connections to 50 N2 devices can be supported on a single Total distance between devices is Network repeaters and other available through third party may also be used addition to Johnson Controls HVAC controls the supports Metasys compatible devices that and control lighting card access and systems The N30 supports many other control components including variable drives boilers chillers fire systems and monitoring equipment N30 Supervisory Controller Workstation n30 3 N30 Network Example Protocol a network card installed up to 50 N30s can peer to peer using BACnet over the Ethernet bus This means node shares data and has access to on all other controllers can view data anywhere in the when connected on the Ethernet network connected directly to an N30 BACnet protocol standard allows inter vendor and easy system integration The Society of Heating Refrigerating and Conditioning Engineers ASHRAE defined the and it is a requirement in many Conformance N30 communicates via BACnet an industry protocol developed by ASHRAE for communication Supports Annex J BACnet standard including Protocol IP support Protocol Implementation Conformance PICS is in the appendix of the Supervisory Controller Technical Manual 689.1 Fully meets Conformance Level 4 providing sharing and alarm management is dependent on media type level and conformance level Supervisory Controller 3 Interface Options Set Release 2.0 and later can be used with Release 3.0 M Web provides an way for customers to increase system locally or remotely to a Metasys system Processing a point goes into alarm the N30 sends to display the alarm point and an alarm message allowing a fast to any system problems Trend logs monitor the attributes of points over time They are used to define wide characteristics Event and Runtime Totalization objects the tracking of consumable usage number times specific events occur and how long remains in specified states Dial In Out feature allows remote access to your Building System BAS in order to Alarm dial out to a workstation or printer specified alarms dial in from M Series Workstations or PC with emulation dial in for commissioning troubleshooting Workstations Release 2.0 and later can be used with Workstations These workstations allow N30 to via direct connection through serial or over an Ethernet network move through buildings floors and areas by pointing and clicking on symbols in trending dynamic graphics for Process Control OPC and interfacing and much more using software components that are to customize the workstation for each requirements Terminal N30 can be accessed with a VT100 Terminal a Personal Computer PC with a VT100 Emulator This option allows low cost direct or remote connection to the N30 for text configuration of objects Access N30 Supervisory Controller identifies users and their access privileges password identification For authorized using the N30 is easy levels of password protection are available authorization levels range from Configure to Only Access to the functions of the N30 is according to the specific needs of a given N30 Supervisory Controller Building Operation N30 is specifically tailored to meet the needs building owners and managers who are looking an affordable way to monitor and control mechanical systems such as dual duct single duct and packaged air units units unit ventilators heat pumps and boilers Variable Air Volume VAV systems Scheduling N30 Weekly Scheduling feature allows the to define when an event should occur An can be programmed for any day of the week or calendar date Objects may define groups for easy facility These groups include devices or other objects according to the user Management define a database offline or online either connected to an N30 via the Ethernet or from a remote site via a phone line users upload download application specific through the N30 without affecting operations of the installation and hardware features of N30 include DIN rail or wall mount non volatile memory to archive all programs data and alarm Light Emitting LEDs to allow easy troubleshooting System Interlocking enables information from one or more controllers to trigger a set of control to be issued to other HVAC It also allows analog or binary data to shared between controllers For example this could be used to eliminate the need for an air temperature sensor wired to each saving hardware and installation costs Supervisory Controller 5 Connections efficient management of remote sites a single can monitor multiple sites via dial up connections or a Local Area LAN Management Features Start Start automatically determines the correct to start HVAC systems to ensure the facility is for occupants at the scheduled time It to seasonal variations and minimizes the used Limiting and Load Rolling Limiting sheds and restores outputs on a basis to prevent demand from exceeding limits Rolling cycles equipment on and off to the total electrical power consumption Workstation Workstation

Related Files