Kidde 3100562-EN R003 Genesis Chime-Strobe Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-3100562-en-r003-genesis-chime-strobe-installation-sheet-6175029843.pdf |
---|---|
Type | |
Size | 819.91 KB |
Downloads |
Text Preview
Installation this device in accordance with applicable requirements in the editions of the NFPA codes and standards and in accordance the local authorities having jurisdiction Electrocution hazard To avoid personal injury or death electrocution remove all sources of power and allow stored to discharge before installing or removing equipment Electrical supervision requires the wire run to be broken at terminal Do not loop the signaling circuit field wires around the install the chime strobe Remove the cover by depressing both tabs on the top of the unit a small screwdriver and twisting slightly Set the chime signal sound output level and desired operation See Figure 1 change the chime signal from steady to temporal cut from J1 to the edge of the circuit board change the chime operation from noncoded to coded single cut from circle J2 to the edge of the circuit board change the chime sound output level from high dB to low dB the J3 trace between the holes Slide the candela switch to the desired candela output by aligning with the indicator located beside the switch See Figure 2 Connect the chime terminals to the signal circuit field wiring For unit to function properly observe polarity See Figure 1 single stroke coded voltage operation see Figure 3 constant noncoded voltage operation see Figure 4 Mount the unit onto a compatible electrical box making sure not to the mounting screws Replace the cover by aligning it at the bottom and then snaping it at the top Test the unit for proper operation 1 Chime settings J3 J1 Chime signal jumper J2 Coded non coded jumper J3 Chime sound output Chime Strobe Sheet Genesis Chime Strobe is a fire alarm notification appliance for indoor walls See Table 1 for a list of models chime includes field configurable options for selecting dB output signal and constant noncoded voltage or single stroke coded operation A Genesis Series Signal Master is required when are configured for coded operation strobe includes a field configurable switch for selecting the desired output The candela output setting is locked in place and visible after final installation This strobe features an synchronization circuit to comply with the latest of UL 1971 Signaling Devices for the Hearing Impaired operation requires a separately installed synchronization module Synchronization module requirements are determined by your See the control panel or power supply compatibility list for synchronization devices 1 Models number 15 to multi cd white 15 to multi cd white with marking 15 to multi cd red 15 to multi cd red with marking plate white plate red 2018 United Technologies Corporation 3 3100562 EN REV 003 ISS 13MAR18 2 Candela switch unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement a visual inspection and an operational test twice a year or as by the local authority having jurisdiction not change the factory applied finish 5 UL 1971 minimum light output of rating vs angle 10 15 20 Angle Minimum UL required candela light output of rated candela vertical specification of rated candela horizontal specification level output operating output level output settings Operation modes size electrical environment humidity VDC or 24 VFWR nominal Table 2 at 15 30 75 and 110 cd Table 3 dB strokes per minute pattern 60 strokes per minute voltage controlled by voltage to 18 AWG 0.75 TO 2.50 mm in 64 mm deep single gang box in square box 1 1 2 in 38 mm 2 gang in octagonal with G1T or G1RT trim to 120 0 to 49 to 93 noncondensing 3 Wiring for single stroke coded voltage operation Chime IN coded power signal Strobe IN continuous power signal Resistor value determined by the control panel Genesis Signal Master Module To next appliance EOL resistor or Class A circuit return One wire each side of screw head Polarity is shown in alarm condition The strobe circuit can be silenced without turning off strobes 4 Wiring for constant noncoded voltage operation From NAC output To next appliance EOL or Class A return Signal polarity is shown in the alarm condition 3 3100562 EN REV 003 ISS 13MAR18 cd cd 2 Strobe operating current in RMS A Volts direct current regulated and filtered Volts full wave rectified currents shown above were measured by UL at 16 VDC and VFWR cd cd 3 ULI Ratings temporal output private mode dB Decibels A weighted 464 Sound level output at 10 ft 3.05 m measured in a reverberant at 16 V dB information rating class UL Indoor 24 DC and 24 FWR UL 1971 requirements Maximum resistance between any two devices is to specifications for the synchronization module this strobe and the control to determine allowed wire resistance UL 1638 UL 1971 and UL 464 private listings information contact information see www edwardsfiresafety com 3100562 EN REV 003 ISS 13MAR18 3