Kidde 3101019-EN R017 F-Series Conventional FACU Compatibility List 06-09
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-3101019-en-r017-f-series-conventional-facu-compatibility-list-06-09-2195678304.pdf |
---|---|
Type | |
Size | 730.89 KB |
Downloads |
Text Preview
Conventional FACU List compatibility lists 1 Compatible detectors 1 number smoke detector and base smoke detector smoke detector and base smoke heat detector and base smoke detector photoelectric smoke heat detector 2 3 smoke detector 2 3 smoke detector 3 temperature heat detector 135 58 3 of rise heat detector 135 58 3 smoke detector 12 24 VDC smoke detector 12 24 VDC smoke detector 12 24 VDC and heat sensor FT RoR smoke detector 8.5 to 33 VDC with FT RoR heat sensor and auxiliary relay smoke detector 12 24 VDC smoke detector 12 24 VDC and heat sensor FT RoR smoke detector 12 24 VDC smoke detector 12 24 VDC smoke detector 12 24 VDC and heat sensor FT RoR smoke detector with CleanMe to 33 VDC base CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 IDC 2020 Carrier 18 3101019 EN REV 017 ISS 28AUG20 18 number base IDC smoke detector with CleanMe fixed and rate of rise heat 8.5 to 33 VDC smoke detector 12 24 VDC response photoelectric smoke detector VDC with heat sensors rate of rise and 57 135 fixed heat detector response photoelectric smoke detector VDC with remote alarm trouble LED smoke detector 12 24 VDC with relay smoke detector and base smoke detector smoke detector and base photoelectric smoke heat detector base smoke detector smoke heat detector smoke detector 2 3 2 3 smoke detector 3 temperature heat detector 135 58 3 of rise heat detector 135 58 3 2 3 smoke detector 12 24 VDC smoke detector 12 24 VDC smoke detector 12 24 VDC and heat sensor FT RoR smoke detector 2 3 smoke detector smoke detector smoke detector photoelectric smoke heat detector 3 temperature heat detector 135 58 3 of rise heat detector 135 58 smoke detector 12 24 VDC 3 smoke detector 12 24 VDC smoke detector 12 24 VDC and heat sensor FT RoR 702E 702U 702E 702U 702E 702U 702E 702U 702E 702RE 702U CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 CSBU 3 CRB4U 1 3101019 EN REV 017 ISS 28AUG20 number base IDC You can install automatic detectors on Class A or Class B alarm unverified circuits with dry contact devices You can install automatic detectors Class A alarm verified circuits with dry contact devices You may install automatic detectors on Class B alarm verified circuits with dry contact unless noted otherwise Do not install on Class B alarm verified circuits unless installed in a resistive base Do not install on Class B alarm verified circuits with dry contact devices 2 Compatible duct smoke detectors 1 2 number 1 2 1 2 duct smoke detector duct smoke detector photoelectric duct smoke detector duct smoke detector duct smoke detector duct smoke detector IDC 48 4 photoelectric duct smoke detector Do not install on alarm verified circuits Do not install with dry contact devices on the same circuit 3 Compatible notification appliances number number 3101019 EN REV 017 ISS 28AUG20 18 18 number