Kidde 3101080-EN R006 FX-IDC1A Analog Class A Single Input Module Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Analog Class A Single Module Installation Sheet module is an analog addressable device used to connect a open alarm supervisory or monitor type dry contact initiating circuit IDC to a control panel This module is designed for A circuit operation device address is set using the two rotary switches located on the of the module One device address is required device can be preset for alarm or supervisory operation using the switch located on the front of the module The module can also configured for other device types through front panel programming the configuration utility The configuration utility is also used to the device switch operation following slide switch settings determine the operation of the Setting the initial slide switch position is generally performed module installation This setting can be changed while the is operating but the change must be confirmed through front programming 1 Slide switch settings Operation used Supervisory nonlatching US marketplace type description 1 latching Configures the module for open dry contact initiating devices the NO input contact of an initiating is closed an alarm signal is sent to control panel and the alarm condition is at the module Factory default latching Canadian marketplace Configures the module for open dry contact initiating devices the NO input contact of an initiating is closed a supervisory signal is sent the control panel and the supervisory is not latched at the module Configures the module for normally dry contact initiating devices When the input contact of an initiating device is a supervisory signal is sent to the panel and the supervisory condition is at the module Additional device types are available through front panel or the configuration utility Refer to the applicable control technical reference manual 1 Slide switch operation module provides a bicolor LED that shows its status Green LED flashes Red LED flashes and wire this device in accordance with applicable national and codes ordinances and regulations This module will not operate without electrical power As fires cause power interruption you should discuss further with your local fire protection specialist This module does not support conventional smoke detectors The module is shipped from the factory as an assembled unit it no user serviceable parts and should not be disassembled install the module Verify that all field wiring is free of opens shorts and ground Make all wiring connections shown in Figure 4 Set the module address Refer to the panel technical reference for a list of valid addresses a screwdriver to adjust the two rotary switches on the front of module Set the TENS rotary switch 0 through 12 for the 10s 100s digit and the ONES rotary switch for the 0 through 9 For example device address 21 set the TENS rotary switch 2 and set the ONES rotary switch to 1 see Figure 2 Set slide switch P1 to the appropriate setting Refer to Figure 1 Mount the module on the electrical box using the screws provided the electrical box Mount the wall plate on the module using the hardware shown in 3 2 Module address 6 7 0 Insert screwdriver here 2020 Carrier 2 3101080 EN REV 006 ISS 19OCT20 3 Module installation Cover plate plastite screw 2X Wall plate Screw 4 Module wiring the device as shown in Figure 4 Be sure to observe the polarity the wires All wiring is power limited and supervised This module does not support two wire smoke detectors Refer to the control panel technical reference manual for wiring line voltage fault impedance device circuit IDC circuit resistance circuit capacitance size environment humidity temperature range 20.6 V peak to peak k 25 per wire to 18 AWG 0.75 to 2.50 mm2 16 and 18 AWG are American 4 inch square in 64 mm deep 2 gang box 4 in square box 1 1 2 in mm deep box to 120 0 to 49 to 93 noncondensing to 140 to 60 Module Compatible electrical box electrical boxes To next device From previous device Class A or Class B Class A information contact information see www kidde esfire com Maximum 25 resistance per wire Maximum 12 AWG wire minimum 18 AWG wire Maximum 10 VDC at 350 Typical normally open NO initiating device 2 3101080 EN REV 006 ISS 19OCT20

Related Files