Kidde 3101090-EN R008 FX-278 Double Action Pull Station Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-3101090-en-r008-fx-278-double-action-pull-station-installation-sheet-8419726350.pdf |
---|---|
Type | |
Size | 891.59 KB |
Downloads |
Text Preview
Double Action Pull Installation Sheet FX 278 Double Action Pull Station combines a dual action pull with a single input analog addressable mini module mounted on back of the unit The pull station requires two actions by the user to an alarm First to access the alarm handle raise the upper marked LIFT THEN PULL HANDLE Second pull the alarm to initiate an alarm device address is set using the two rotary switches located on the of the mini module One device address is required mini module is configured for alarm latching operation When the station is activated an alarm signal is sent to the control panel the alarm condition is latched at the pull station The pull station be manually reset prior to resetting the panel FX 278 provides two status LEDs The LEDs are visible from the of the FX 278 1 LED location a screwdriver to adjust the two rotary switches on the front of module Set the TENS rotary switch 0 through 12 for the 10s 100s digit and the ONES rotary switch for the 0 through 9 For example device address 21 set the TENS rotary switch 2 and set the ONES rotary switch to 1 see Figure 2 Verify that all field wiring is free of opens shorts and ground faults connecting to the module terminals Make all wiring connections to the terminal block discussed in and shown in Figure 4 Open the pull station by using a slotted screwdriver to twist the release screw counterclockwise while pulling the cover away its backplate Mount the pull station in the electrical box use of the glass rod is desired pull the glass rod release lever install the glass rod through the mounting bracket on the front the pull station Set the toggle switch to the NORMAL position and snap the cover its locked position 2 Module address Insert screwdriver here 3 Pull station installation Red LED Alarm active Green LED Normal and wire this device in accordance with applicable national and codes ordinances and regulations This pull station does not operate without electrical power fires frequently cause power interruption discuss further with the local fire protection specialist The pull station is shipped from the factory complete with a input mini module attached The module contains no user parts and should not be disassembled install the pull station To meet the Americans with Disabilities Act ADA mount the box 48 inches max from the floor and attach the pull using screws provided with the electrical box Set the module address Refer to the panel technical reference for a list of valid addresses Compatible electrical box Key latch cover release Backplate Toggle switch Glass rod release lever Screw For system supervision do not loop the circuit wires around terminals Break the wire run at each terminal the device as shown in Figure 4 Be sure to observe the polarity the wires 2020 Carrier 2 3101090 EN REV 008 ISS 21OCT20 additional wiring information refer to the documents listed on the panel label wiring is power limited and supervised 4 Pull station wiring SLC in from previous device or control panel SLC out to next device or EOLR maximum maximum line VDC at 350 V peak to peak size electrical boxes North American 2 1 2 in 64 mm deep to 18 AWG 0.75 to 2.5 mm order surface boxes glass rods environment humidity gang box 4 in square box 1 1 2 in mm deep box with single gang mud Cream enamel finish Red enamel finish P N 276 GLR pkg 20 rods P N 27165 pkg 12 rods to 120 0 to 49 to 93 noncondensing at 32 temperature range to 140 to 60 information contact information see www kidde esfire com 2 3101090 EN REV 008 ISS 21OCT20