Kidde 3101100-EN R006 SA-ETH Ethernet Interface Card Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-3101100-en-r006-sa-eth-ethernet-interface-card-installation-sheet-8609514372.pdf |
---|---|
Type | |
Size | 702.09 KB |
Downloads |
Text Preview
2 Installation and connections Ethernet Interface Installation Sheet SA ETH card provides a standard 10 100 Base T Ethernet connection for connecting to a local network The card can be for uploading and downloading panel configuration history and status to a PC running the configuration utility or connect to a central monitoring station receiver over a network Ethernet card is installed on the plastic assembly and connects to main circuit board via a ribbon cable The Ethernet card must be configured through programming for operation install the Ethernet card Power down the panel by first disconnecting the batteries and disconnecting the main AC power Locate the card slot on the plastic assembly behind the main board and connector J1 on the main circuit board at the of the main board Slide the card into the slot on the plastic assembly as shown in the 1 Attach the card to the plastic assembly using two 6 plastite as show in Figure 2 Connect the ribbon cable P N 7140189 from the card to J1 on the main circuit board J1 is located on the of the main circuit board Connect the network cable See Power up the panel by first connecting the main AC power and connecting the batteries 1 Installation 6 plastite screw To connector J1 on main board Ribbon cable You can use either an RJ 45 patch cable or an RJ 45 crossover 3 SA ETH wiring and LED locations Network cable To network connection router switch etc Ethernet card LED 4 DS4 Collision LED 3 DS3 Duplex LED 2 DS2 Speed LED 1 DS1 Link LEDs are four LEDs on the card that indicate card and network status Figure 3 Card slot on plastic assembly SA ETH card Top right of main circuit 2021 Carrier 2 3101100 EN REV 006 ISS 12JAN21 mode voltage current wire runs 5 cable connector address default mask default default environment humidity information compliance Base T negotiation VDC 34 mA 41 mA feet 60 m Cat 5 cable panel to equipment to 120 0 to 49 to 93 noncondensing at 90 32 device complies with part 15 of the FCC Operation is subject to the following two 1 This device may not cause harmful and 2 this device must accept any received including interference that cause undesired operation Indoor dry information contact information see www edwardsfiresafety com 2 3101100 EN REV 006 ISS 12JAN21