Kidde 3101999-EN R002 Genesis WG4 Outdoor Horn Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-3101999-en-r002-genesis-wg4-outdoor-horn-installation-sheet-3197460258.pdf |
---|---|
Type | |
Size | 2.46 MB |
Downloads |
Text Preview
WG4 Outdoor Horn Sheet synchronize horn operation you must install a separate source See Table 3 When connecting the horn to a control panel verify synchronization operation on the list for the corresponding panel output module 3 Compatible synchronization source models Represents any number of additional characters signal master remote or auxiliary power supply this device in accordance with applicable requirements and in with the local authorities having jurisdiction Genesis WG4 Outdoor Horn is a life safety notification appliance for indoor or outdoor use on ceilings or walls See Table 1 for list of models and Table 2 for a list of accessories surface mount applications mount the WG4 onto a Model 449 box using the gasket shipped with the appliance Electrocution hazard To avoid personal injury or death electrocution remove all sources of power and allow stored to discharge before installing or removing equipment Electrical supervision requires that you break the wire run at each Do not loop wires around the terminals flush mount applications where the mounting surface is flush with surface of the wall or ceiling use the WG4GSKT gasket kit Mount the WG4 horizontally or vertically on either the wall or place the electrical box accordingly See Figure 1 that you need a Model 449 electrical box for waterproof or a standard mount 4 in square box for all other horn includes field configurable jumper options that allow you to the horn pattern to temporal or continuous and the horn volume to or high or When using a Model 449 electrical box discard the gasket that is with the box When using a trim skirt or a surface mount application use the that comes with the WG4 unit 1 Models rated wall ceiling horn white with FIRE rated wall ceiling horn white without marking rated wall ceiling horn red with FIRE marking rated wall ceiling horn red without marking 2 Accessories 1 Outdoor rated surface skirt white for Genesis WG4 1 Outdoor rated surface skirt red for Genesis WG4 or horn strobe or horn strobe 2 Appliance replacement gasket flush mount The trim skirt is outdoor rated when used with the Model 449 box Not compatible with the trim skirts flush mount applications on a flat surface use the WG4GSKT accessory install the horn Remove the cover from the appliance by first removing the six screws See Figure 2 item 1 Position the appropriate gasket over the backplate ensuring that wire slot and other holes line up properly the protective backing from the gasket surface and apply the gasket to the WG4 with the adhesive side the appliance the gasket firmly against the back surface of the appliance that the gasket seats properly Place the optional trim skirt over the electrical box if desired See 2 items 5 and 6 Also see on page 3 for a of compatible boxes Feed the field wiring through the wire slots on the gasket and the See Figure 2 item 3 and Figure 3 item 1 2018 United Technologies Corporation 4 3101999 EN REV 002 ISS 14MAR18 2 Exploded view of the assembly Align the appliance and trim skirt if applicable and then secure backplate to the electrical box with the supplied screws the assembly to ensure that it is securely mounted Set the horn volume Set the horn pattern default horn volume setting is high To set the horn to low cut jumper JP3 See Figure 3 item 2 default horn pattern is a 3 3 temporal output To use a horn pattern cut jumper JP1 See Figure 3 item 3 Connect the horn terminals appropriately to the signal circuit field You must observe polarity for the unit to function properly on page 3 Position the cover over the backplate and then secure it with the cover screws Test the unit for proper operation 1 Horn mounting positions Cover screws 6X Front cover Backplate Optional trim skirt WG4 gasket Electrical box 3 Wire slot and jumper locations Wire slot JP3 horn volume jumper 3 JP1 horn pattern jumper 4 3101999 EN REV 002 ISS 14MAR18 all wiring in accordance with national electrical codes and local requirements Equipment hazard To avoid equipment damage ensure that signal voltage does not exceed the voltage rating of the device 4 Wiring diagram Horn Strobe IN Horn Strobe IN Marking indicates the signal required to activate device Horn Strobe OUT Horn Strobe OUT Not used a visual inspection and an operational test twice a year or as by the local authority having jurisdiction unit is not serviceable or repairable Should the unit fail to contact the supplier for replacement Do not change the factory finish voltage W H D level output tone size electrical box Outdoor environment humidity VDC 24 VFWR nominal 8.5 1.4 in 142 216 36 mm Table 4 Table 5 Table 6 and 7 kHz to 18 AWG 0.75 to 2.50 mm 449 in square by 1.5 in deep box to 151 to 66 to 95 noncondensing 4 Sound pressure level dBA per UL 464 Setting High Low High Low Decibels A weighted 464 Sound level output measured in a reverberant room at 10 ft 5 Sound pressure level dBA per CAN ULC S525 Setting High Low High Low Decibels A weighted Sound level output measured in an anechoic room at ft 3.05 m 6 Directional sound characteristics horizontal pattern per 1 Ref and 115 and 132 1 Angles are measured from a perpendicular axis positive angles to right output dBA Ref 7 Directional sound characteristics vertical pattern per 1 Ref and 110 and 125 Angles are measured from a perpendicular axis positive angles are output dBA Ref 8 Horn operating current in RMS mA continuous dB dB 9 Typical current values mA at 24V dB dB 3101999 EN REV 002 ISS 14MAR18 4 information rating 24 DC and 24 FWR device was tested to the regulated DC FWR operating voltage limits of 16 V and V Do not apply 80 and 110 of these for system operation device complies with part 15 of the FCC Operation is subject to the following two 1 This device may not cause harmful and 2 this device must accept any received including interference that cause undesired operation Class B digital apparatus complies with ICES 003 and outdoor allowed resistance between any two is 20 Refer to specifications for synchronization sources this horn the control panel to determine allowed wire 464 CAN ULC S525 compliance compliance listings information contact information see www edwardsfiresafety com 4 3101999 EN