Kidde 3102149-EN R03 Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-3102149-en-r03-genesis-low-frequency-520-hz-horn-strobe-installation-sheet-7468051923.pdf |
---|---|
Type | |
Size | 2.30 MB |
Downloads |
Text Preview
Genesis Low Frequency 520 Hz Horn Strobe Sheet 1 Models frequency 520 Hz horn white housing FIRE marking standard output clear strobe frequency 520 Hz horn white housing FIRE marking standard output clear light frequency 520 Hz horn red housing no marking standard output clear strobe frequency 520 Hz horn red housing FIRE marking standard output clear light wall mount box white housing wall mount box red housing strobe features an enhanced synchronization circuit to with the latest requirements of UL 1971 Synchronized requires a separately installed synchronization See the control panel or power supply compatibility list compatible synchronization devices and wire this device in accordance with applicable and local codes ordinances and regulations horn strobe should be mounted so that the entire lens is less than 80 in 2.03 m and not greater than 96 in m above the finished floor The entire lens should also 24 in 61 cm or more from the finished ceiling Electrocution hazard To avoid personal injury or from electrocution remove all sources of power and stored energy to discharge before installing or removing Electrical supervision requires that you break the wire at each terminal Do not loop wires around the terminals Genesis Low Frequency 520 Hz Horn Strobe can be for applications where a low frequency alarm notification with strobe light output is required The device is for wall mounting and indoor use only See Table 1 a list of model numbers this device is used as a low frequency sounder in quarters the strobe s candela switch Figure 1 must set to 110 cd horn strobe includes field configurable jumper options for horn strobe also includes a field configurable switch for the strobe candela level This setting is locked in place is visible after final installation or steady horn output dB or high dB output or continuous pattern strobe 2014 UTC Fire Security Americas Corporation Inc 6 3102149 EN REV 03 ISS 20MAY14 install the horn strobe Remove the cover by using a screwdriver to depress and twist both tabs on top of the unit Set the horn signal sound output level and strobe signal the desired settings See Figure 1 change the horn output level from high dB to low dB jumper JP3 change the horn signal from temporal to steady cut JP2 change the strobe pattern from continuous to temporal mode cut jumper JP1 Set the candela output the candela switch to the desired candela output by it with the indicator notch below the switch See 1 Mount the horn strobe as follows Route the signal circuit field wiring through the in the center of the horn strobe mount Mount the horn strobe and flush mount onto a compatible electrical box Figure 2 making not to overtighten the mounting screws See for compatible electrical boxes mount Mount the G4B or G4RB surface mount on the wall Figure 3 and then secure the appliance the box using the fasteners provided with the box Connect the signal circuit field wiring to the horn strobe Figure 4 Observe polarity for the unit to properly Replace the cover by aligning it at the bottom and then it in at the top Test the unit for proper operation To maintain the required agency listings do not factory applied finishes unit is not serviceable or repairable Should the unit fail to contact the supplier for a replacement a visual inspection and an operational test twice a or as directed by the local authority having jurisdiction 1 Horn strobe settings Jumper JP3 Jumper JP2 2 Flush mount Jumper JP1 Candela switch indicator Compatible electrical box Flush mount spacer Horn strobe Cover 8 32 x 1 in screw provided 6 3102149 EN REV 03 ISS 20MAY14 3 Surface mount Surface mount box G4B or Screw 4X provided with Horn strobe or G4RB box Cover environment humidity 4 Wiring diagram voltage horn strobe level output directional output settings size electrical VDC or 24 VFWR 1 Table 6 Table 2 and Table 3 Table 4 and Table 5 at 15 30 75 and 110 cd see 5 Figure 6 and Figure 7 2 allowed resistance between any devices is 20 Refer to specifications the synchronization control module this and the control panel to determine wire resistance flash per second fps to 18 AWG 1.0 to 4.0 mm 4 in square box 1 1 2 in 38 mm in 54 mm deep or G4B G4RB mount box to 120 0 to 49 to 93 noncondensing This device was tested to the Regulated 24 DC FWR operating limits of 16 V and 33 V Do not apply 80 and 110 of these for system operation When this device is used as a low frequency sounder in sleeping the strobe s candela switch Figure 1 must be set to 110 cd 2 UL sound level output dBA 1 and voltage VDC VDC VDC VDC VDC VDC UL 464 Nominal sound level output at 10 ft 3.05 m measured in a room 3 Nominal sound level output dBA temporal tone 1 VDC VDC VDC VFWR VFWR VFWR Measured in an anechoic chamber at 10 ft 3.05 m From NAC output To next device or EOL Polarity is shown in the active condition 3102149 EN REV 03 ISS 20MAY14 6 4 Audible directional characteristics horizontal pattern 1 dB 2 Angles are measured from a perpendicular axis positive angles to right Peak output at 16 VDC set for steady tone 5 Audible directional characteristics vertical pattern 1 dB 2 Angles are measured from a perpendicular axis positive angles are Peak output at 16 VDC set for steady tone output cd 6 Nominal operating horn strobe current in RMS mA VDC VFWR VDC VFWR VDC VFWR VDC VFWR VDC VFWR VDC VFWR Volts direct current regulated and filtered Volts full wave rectified 5 UL 1971 minimum light output of rating vs angle Angle Minimum UL required candela light output of rated candela vertical specification of rated candela horizontal specification 6 Typical horizontal light output profile 110 cd setting cd UL minimum requirement cd 6 3102149 EN REV 03 ISS 20MAY14 7 Typical vertical light output profile 110 cd setting cd UL minimum requirement cd information A Division of UTC Fire Security Corporation Inc Town Center Parkway Bradenton FL USA first two digits of the date code located on product identification label are the year of 24 DC and 24 FWR UL requirements for standards UL 464 1638 and UL 1971 of rating American information contact information see www edwardsutcfs com 3102149 EN REV 03 ISS 20MAY14 6 6 3102149 EN REV 03 ISS 20MAY14