Kidde 3102531-EN R001 KIR-PD Intelligent Photoelectric Smoke Detector Installation Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent Smoke Installation Sheet Upon completion of the original installation and following any or additions to the system perform a calibrated test per NFPA code The Kidde Intelligent devices can this test at the panel which can then generate a system report Refer to Kidde Intelligent Detector Application Bulletin 3102534 EN for additional information on detector placement spacing install the device and wire the base as described on the installation sheet with the base Set the detector address Refer to the panel technical reference for a list of valid addresses Use a screwdriver to adjust two rotary switches on the back of the detector Figure 1 Set the left rotary switch 0 through 12 for the and 100s digit and the right rotary switch for the 0 through 9 Attach the detector to the base by rotating the detector clockwise it snaps into the locked position 1 Setting detector address address 52 shown Insert a screwdriver here to set the address 2 KIR PD features model KIR PD Intelligent Photoelectric Smoke Detector is an device that uses an optical sensing chamber to detect The detector analyzes data from the sensing chamber to whether to initiate an alarm indicator The LED indicator see Figure 2 displays the following Normal Green LED indicator flashes no action Alarm active Red LED indicator flashes evacuate the area This detector does not operate without electrical power As fires cause power interruption discuss further safeguards the local fire protection specialist This detector does not sense fires in areas where smoke cannot the detector Smoke from fires in walls roofs or on the side of closed doors may not reach the detector Photoelectric detectors have a wide range of fire sensing and are best suited for detecting slow smoldering fires To ensure proper operation store the detector within the ranges Allow the detector to stabilize to room before applying power The dust cover supplied must remain on the detector during and be removed prior to commissioning and service dust cover is not a substitute for removing the detector during construction or heavy remodeling Self locking tab LED indicator Do not use smoke detectors with detector guards unless the has been evaluated and found suitable testing notify the proper authorities that the fire alarm system is maintenance and will be temporarily out of service and wire this device in accordance with applicable national local codes ordinances and regulations perform an initial installation test Canada install according to CAN ULC S524 Standard for the of Fire Alarm Systems CSA C22.1 Canadian Electrical and the local authority having jurisdiction Remove the detector from its base and verify that the proper address trouble signals and messages are reported For KIR PD detectors placed in the air ducts verify that the airflow within specifications See on page 2 2017 United Technologies Corporation 2 3102531 EN REV 001 ISS 15AUG17 wired for Class A operation verify that the detector continues to first with SLC IN disconnected reconnect SLC IN and with SLC OUT disconnected Refer to the installation sheet the base information UL 268 UL 268A Place a momentary ground fault on the SLC circuit to verify to 3.94 ft 1.7 to 12.35 m obscuration American smoke range compliance device complies with part 15 of the FCC Operation is subject to the following two 1 This device may not cause interference and 2 this device must any interference received including that may cause undesired Canada Class A digital apparatus complies with ICES 003 information contact information see www kiddelifesafety com of ground fault detection circuitry Run a system detector maintenance report on all detectors and that the readings fall within acceptable limits Perform a sensor function test as described below perform a sensor function test desired use the fire alarm control panel to put the detector or into a service group for testing Refer to the panel technical manual for instructions Activate the smoke sensor using No Climb Products model Smoke FireTech Smoke or Smoke Sabre smoke aerosol a smoke generator or the Testifire detector tester per the instructions ensure proper operation plan maintenance regular or selected of detector in accordance with the AHJ and all applicable governing codes or standards Refer to CAN ULC S536 Standard for the and Testing of Fire Alarm Systems and NFPA 72 National Alarm and Signaling Code to application bulletin P N 3102534 EN for additional information cleaning instructions voltage operating level to 19.95 VDC to 35 Hz with an amplitude of in velocity 1 to 4,000 ft min 0 to 20.32 m s mounting distance from in 305 mm max bases KI SB4 KI RB4 KI IB4 KI ABDT KI ABLT detector testers 1000 Testifire 2000 environment humidity to 120 0 to 49 to 93 noncondensing temperature to 140 to 60 compensation For duct installation use a K DMP duct detector mounting plate and per P N 3102482 EN 2 3102531 EN REV 001 ISS 15AUG17

Related Files