Kidde ANS-5002 R5 16

File Preview
File Preview
Click below to download for free

File Data

Name kidde-ans-5002-r5-16-8254703916.pdf
Type PDF
Size 1011.18 KB
Downloads

Text Preview

ANS25A ANS50A ANS100A INSTRUCTIONS ANS25A ANS50A ANS100A is a self contained amplifier tone generator power and supervisory interface It is designed to be used in conjunction with the ANS 25 100 to provide additional speaker output power It may also be used stand alone in with a Fire Alarm Control Panel to provide voice evacuation where an automatic is not desired and operation is identical to the ANS 25 50 100 see Installation Instructions ANS 5001 With the exception that no digital message is present When used in with the ANS 25 50 100 the Expander will act as a slave reproducing the and message generated by the master When used as a stand alone the Expander connect to the FACP exactly as the ANS 25 50 100 does to provide automatic tone in and voice override capability terminal designations and volume controls are identical to the ANS 25 50 100 One is that on the Expander SN1 determines Tone Master Slave Battery and supervision There is no SN2 defaults are Expander as Slave OFF Temporal Whoop Signal OFF OFF OFF OFF OFF Slave ON Master setting ON Battery connected OFF No Batteries OFF No Mic ON Mic connected Expander as Master Stand Alone OFF Temporal Whoop Signal OFF OFF OFF OFF ON Master setting ON Battery connected OFF No Batteries ON Mic connected Network Detail 0 UP 1 DOWN Tone Selection 1 Sets the evac tone Settings 0 Temporal Whoop 1 Temporal Chime ratings and specifications see ANS 25 50 100 Installation Instructions P N ANS 5001 464 520 Hz Low Frequency Signal for Sleeping Areas Models ANS25A and ANS100A when used in conjunction with models ANS25 and are tested compliant with UL 464 520 Hz Low Frequency Signal for Sleeping Areas with the following speakers Series G4HF and GCHF ANS 5002 R5.16 1 of 2 2015 Walter Kidde Portable Equipment Inc All rights reserved ALARM CONTROL PANEL POLARITY POWER VAC Limited Power Limited Power Limited 25A 50A 100A INSTALLATION Power Limited Style Life Safety Speakers Strobes connected and powered separately wire to maintain supervision Do not loop wire around speaker terminals faults are indicated at 10K impedance or less 2 3 50A 100A Style Power Limited Fire Emergency Use Only wiring connections wire clamp screw 14 18 AWG wire clamp screw 12 18 AWG wire entry terminal 18 26 AWG gauge determined by circuit load Wire Harness Non Power Limited Current 1A max Wire is Provided 25A 50A 100A Slave Connection Detail ALARM CONTROL PANEL wiring connections wire clamp screw 14 18 AWG wire clamp screw 12 18 AWG wire entry terminal 18 26 AWG gauge determined by circuit load 2 3 Power Limited Non Supervised wiring must be only run in the same cabinet or between cabinets which are piped together within the same room at a maximum of 20 1 3 2 3 25V 50A 100A pin ribbon cable supplied may be used place of hard wired connections TB2 11,5,3,1 Power Limited 50 100 50A 100A Switch SN1 6 SN1 8 must be in OFF position for all Slave modules All Power and Speaker connections remain unchanged Shorting blocks removed from slave units for pass through supervision contact information see www edwardsfiresafety com 2015 Walter Kidde Portable Equipment Inc rights reserved ANS 5002 R5.16 2 of 2 2015 Walter Kidde Portable Equipment Inc All rights reserved

Related Files