Kidde FX85001-0618 -- Carbon Monoxide Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-fx85001-0618-carbon-monoxide-detector-0435296718.pdf |
---|---|
Type | |
Size | 927.43 KB |
Downloads |
Text Preview
FireworX Catalog u Conventional Initiating Devices Monoxide with SafeTestTM SafeAirTM 250 CO carbon monoxide CO detector is an accu and reliable means of alerting building occupants of potentially levels of CO in the protected area The internal electro sensor communicates with a sophisticated on board that accurately tracks CO levels over time commercial grade detection technology results in quick reliable sensing fast reset time and superior false alarm Its small size allows the 250 CO to blend inconspicu with any decor and its smooth contoured design is compat with both residential and commercial environments by normal indoor temperature variations the 250 CO self adjusts for environmental changes and operates reli under a wide variety of conditions It also monitors its own and automatically compensates for sensitivity drift the course of its service life Features SafeTest enables a full functional test with spray of real CO Electro chemical sensing technology Transmits sensor end of life to the control panel and central if the system is monitored Fully listed to the latest UL 2075 CO standard for residential or occupancies Built in trouble power supervision relay Six year sensor Self diagnostics keep the device operating optimally through its service life 12 or 24VDC operation and 150mA relay contact configurable normally open or normally closed operation 250 CO features the SafeTest functional test feature which testing with real CO gas SafeTest meets the functional requirement in NFPA 720 2009 2012 editions all CO detectors the 250 CO has a limited service life When approaches this point the 250 CO six year end of life timer triggers a warning locally at the control panel and at a central monitoring station indicating that the device be serviced Large SEMS terminals ease wiring installation 14 to 22 AWG One touch TEST HUSH button simplifies local operation Integrated 85 dBa temporal 4 sounder for local notification On board LED provides local alarm and trouble indication Inconspicuous footprint and attractively contoured design Adapter plate makes replacing ESL 240 COe CO detector integrated temporal 4 sounder provides local signaling capabil for the 250 CO and it easily interfaces with any listed intrusion or alarm system by means of its 150mA output relay Its low current results in little additional demand on the system power supply 250 CO fully complies with the latest UL 2075 requirements allows for installation in a wide range of both residential and settings 1 of 4 D A T A S H E E T FX85001 0618 to be used for installation purposes Issue 4 SafeAir 250 CO Carbon Monoxide Detector is intended for indoor dwelling unit applications in both residential and occupancies including single multiple family residential hotel rooms dorm rooms and other areas approved the authority having jurisdiction AHJ The 250 CO detec can connect to either UL 985 Household Fire Warning or UL Commercial Fire control panels It is not intended for use in applications such as gasoline refineries or parking ga which require different listings The 250 CO detector has an adapter mounting plate for the ESL 240COe CO detector purchase the plate order P N 250 COPLT 5PKG a suitable location is critical to the operation of CO Install the 250 CO in accordance with NFPA 720 Stan for the Installation of Carbon Monoxide CO Detection and Equipment Place wall mounted detectors at least 5 ft m up from the floor For ceiling mounted applications place detector at least 1 ft 0.3 m from any wall hotel rooms and dorm rooms CO detector locations 9 Within 10 ft 3 m of all sleeping areas including areas such 9 In a suitable environment areas with a temperature range of to 104 0 to 40 and with a relative humidity range of 0 90 noncondensing 9 In residential dwellings locate detectors in every bedroom 10 ft 3 m of sleeping areas and on each level At a place one detector outside the sleeping areas Recommended locations for CO detectors check with your local building codes and Authority Having Jurisdiction specific CO location requirements in your area CO detector locations in commercial occupancies 9 On every habitable level of the building based on an engineer evaluation considering potential sources and migration of monoxide 9 In any area required by local building codes legislation or Having Jurisdiction 9 On a firm permanent surface not install the CO detector 8 Within 10 ft 3 m of a fuel burning appliance 8 Near air conditioners heating registers and any other ventilation that may interfere with CO gas entering the detector 8 Where furniture or draperies may obstruct the airflow 8 In a recessed area functional test This test facilitates the use of CO test to verify the correct operation of the detector Functional is mandatory per NFPA 720 as of January 2012 The mode is activated by pressing and holding the test hush for 5 10 seconds While in SafeTest mode directing UL CO testing spray at the sensor port will result in the acti of the alarm relay and the sounder and red LED to activate a temporal four pattern Pressing and holding the test hush will SafeTest mode Note See 250 CO installation instructions for on approved CO test spray 85 dB temporal four sounder alarm The 85 dB sounder provides a distinctive alarm notification that easy to differentiate from smoke alarm notification devices The beeps four times rests five seconds and then repeats the button Use the test hush button to test the alarm and an activated alarm Pushing the test hush button silences integral sounder for five minutes The red alarm light stays on if CO is still present after five minutes the detector once again in the temporal four pattern The hush feature does not at CO levels above 350 ppm parts per million of sensor life indicator The detector uses both a flash green LED and intermittent sounder chirps to indicate that the needs replacing To silence the detector push the test button The detector also begins signaling a trouble when the sensor is approaching end of life When connected to a Listed panel the trouble relay can report a trouble condition locally the panel and optionally at the central station if the system is trouble relay The trouble relay opens to indicate a condition upon lost power CO sensor cell trouble or cell 250 CO Carbon Monoxide Detector is a four wire device to use a Class 2 output from a control panel or auxiliary supply Listed to UL 985 or 864 standards wiring must conform to the NFPA 70 National Electric Code UL NFPA 720 and applicable codes Use 14 to 22 AWG wire Connect the CO detector only to a zone dedicat exclusively for CO detection and that is monitored 24 hours day Do not connect to an initiating circuit with fire or security Failure to properly install test and maintain a CO may cause it to fail potentially resulting in loss of life 250 CO 240 COe adapter plate the 250 COPLT 5PKG plate when replacing 240 COe with a 250 CO cover the footprint of the For example use plate to cover any paint left behind from 240 COe 2 of 4 D A T A S H E E T FX85001 0618 to be used for installation purposes Issue 4 Single device single zone NO pro by the safety Multiple devices single zone NO NC NO NC Multiple devices separate alarm trouble zone NC NO C NC NO C device by the life safety system pro by the safety pro by the safety 3 of 4 D A T A S H E E T FX85001 0618 to be used for installation purposes Issue 4 us edwards fire fs utc com www edwardsfire com is an EDWARDS brand Town Center Parkway FL 34202 2013 UTC Fire Security Americas Inc All rights reserved subject to change