Kidde K85000-0373 -- FX Series Intelligent Quick Reference Card

File Preview
File Preview
Click below to download for free

Text Preview

SPECIFICATIONS loops support of any type cation appliance supply Operating Loop operating power Power 1 Power 2 output panel current placement SERIES SMALL BUILDING FIRE ALARM SOLUTIONS loop Class B Class A up to 64 devices Class B Class A optional amps each loop expandable to 4 Class A or B loop supports up to 250 devices Class B or 2 Class A amps each FWR total at 120VAC 60Hz circuit Aux power 2 Nominal 500mA FWR total at 230VAC 50Hz total 2.5A max ct 120VAC 60Hz circuit 24VDC nominal 500mA FWR total at 230VAC 50Hz VDC NAC minimum voltage 19.5 VDC 20.4 V battery voltage V peak to peak VAC 60 Hz 230 VAC 50 60 Hz circuit 24 VDC nominal at 500 mA circuit 24 VDC nominal at 500 mA to 25.7 VDC 155 mA Alarm 204 mA 172 mA Alarm 267 mA to 11 AH p n 12V10AH batteries external cabinet for larger batteries external cabinet for larger batteries must be sealed lead acid type only Maximum charging capacity 26 Ah to 18 A H batteries loop resistance 66 loop resistance 66 loop capacitance 0.5 Style 4 6 7 wiring 64 isolators max per loop loop capacitance 0.5 Style 4 6 7 wiring 64 isolators max per loop S10A S11A the maximum quantity of detectors per circuit mA for FX 2WIRE see the UL compatibility list for your panel circuit max detector current ID Trouble contact contact rating communications annunciator Groups zones Listing Note 1A possible if you reduce total available NAC power by 500mA If 1.0A is required a Listed 24VDC auxilary booster must be used 2.55 V Current 30 mA max drops max RS 485 Class B Class A C 24 VDC 1 A resistive load A 24 VDC 1 A resistive load 0 to 49 32 to 120 Humidity 0 to 93 RH noncondensing terminals rated for 12 to 18 AWG 0.75 to 2.5 sq mm ULC CSFM FDNY max max one loop supports up to 64 devices of any type One loop supports up to 250 intelligent devices be expanded to four loops with the addition of an SLC module loop supports 250 devices 125 detectors and 125 modules 2 Class B or 2 optional Class A NACs 4 Class B or 2 Class A NACs combination of up to eight LCD LED graphic serial annunciators Remote Diagnostics Station Communicator option modules SA 232 and SA USB Two Form C one Form A Power programmable Power resettable or continuous Conventional IDCs additional NACs with RZI16 2RS module REFERENCE relevant literature for full listing of available models and options mounting holes with attached with door and ring attached INTELLIGENT PANELS Fire Alarm Control Panel Points Fire Alarm Control Panel dialer 64 Points Alarm Control Accessory Semi Mt Trim Kit FX 64 Fire Alarm Control Panel loop 250 Devices expand to loops 1,000 Devices with SLC see below as FX 1000 with dialer Mt Trim Kit FX 250 OPTION module 250 device loop module two 250 device 500 devices total Zone Interface Module Class B Initiating Device and two Class B Supervised Circuits Line Dialer Modem supports ID mounts in cabinet Serial Port for printers mounts in cabinet Port Slave mounts in A adapter module Provides A capacity on NACs Mounts cabinet FX 64 systems only interface for Printer and connection mounts cabinet Annunciator Module 16 groups LEDs per group Mounts in cabinet systems only REMOTE text annunciator without common Red text annunciator common Red LED zone annunciator controls Red LED zone expander cable zone card Red enclosure for Remote enclosure for Remote and Remote Expander Mount Box POWER 12V10A BC 1R Amp Booster Power Supply Amp Booster Power Supply Ah Batteries Ah Batteries Ah Batteries Cabinet detector Heat detector and Monoxide Frequency Audible Detector Base Box for Audible Base alarm LED Use with standard only DUCT SD TXX SD TRK SuperDuct Detector Tubes for SuperDuct Test Stations for SuperDuct INTELLIGENT A B Two Wire Module Input Mini Module Input Module Input Water ow Supervisory Module Fault Isolator Module module Relay Module Tone Generator for Detectors Horn Strobe Low Frequency cd Marked 24VDC red Strobe Low Frequency 15 110 Marked 24VDC red Strobe 15 75 cd 16 33 VDC Marked Horn Strobe 15 75 cd 16 33 Red Marked Horn Constant or T3 Temporal VDC Red Marked Ring EG1 Series Red Multi cd Strobe 15 115 cd red Multi cd Strobe 95 177 cd red Multi cd Horn Strobe cd Marked red Multi cd Horn Strobe cd Marked red Weatherproof Strobe 110 cd Horn Strobe 110 cd Weatherproof Box for strobes Weatherproof Box for strobes Weatherproof Surface Box red MANUAL Action Pull Station Mount Box Red for E 278 Action Pull Station Mounting Box for FX 270 INTELLIGENT BASES Smoke Detector Smoke Heat Detector Detector RoR or Fixed Base Detector Base Detector Base Detector Base Monoxide detector with Carbon Monoxide SPDT relay Contact Rating 10 115Vac and Coil Power 24 24Vdc 115Vac or 230Vac DPDT relay Contact Rating 10 115Vac and Coil Power 24 24Vdc 115Vac or 230Vac SPDT relay Contact 10 Amps 115Vac and Coil 24 Vac 24Vdc or 115Vac Short Catch Plate Flush Wall Mounted Surface Wall Mounted mounting holes DIMENSIONS IN CM D2 D3 D8 Optional trim kits provide 3 4 frame on top bottom and sides D4 D5 D6 D7 D9 POWER SUPPLY relevant literature for application details POWER FAIL DELAY OPERATION FX IDC1B is for AC delay Line Voltage 6.5 AMP BOOSTER 50 60Hz 390 watts 10 AMP BOOSTER 50 60Hz 580 watts Rating

Related Files