Kidde K85000-0394 -- FX Series Conventional Quick Reference Card
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85000-0394-fx-series-conventional-quick-reference-card-7613285409.pdf |
---|---|
Type | |
Size | 981.14 KB |
Downloads |
Text Preview
FX SERIES SMALL BUILDING FIRE ALARM SOLUTIONS System Indicators Zone Indicators Remote Annunciator Common Controls Remote Relay Modules Form C Relays Convertible Class B Device Circuits simplicity of wiring valuable features only among systems Available in 5 and 10 zone models CleanMe feature provides remote if 521 Series detector out of UL limits Automatic drift compensation detector life Precision UL 1971 signal and optional audible over just two wires Up to 7.5 amps available NAC power equipment costs Fully integrated upload download enables PC and off premise Zone or NAC pairs convertible to Class A circuits Combination Waterflow and zones NACs programmable by zone and selectable for continuous or coded outputs or protocol Model illustrated 5 Zone Models also table for specifications Convertible Class B Notification Appliance Circuits F DACT1 use with FX Series firmware v4 x and later Three Form C Device Circuits IDCs Combinations Appliance Circuits NACs Combinations Appliance Circuits NACs Supply NAC current Panel Current Draw Placement Current Output Alarm Current Trouble Supervisory Contacts wire gauge Communication Bus Annunciators Relay Modules B A B A amps total amps total amps each 3.5 amps total 104 mA Alarm 224 mA amps each 7.0 amps total 128 mA Alarm 242 mA Ah maximum up to 10 Ah in cabinet Ah maximum up to 10 Ah in cabinet amps max May be programmed as resettable Contacts at 30 Vdc 1 A resistive load Vdc regulated mA 12 AWG resistance 13 Ohms Maximum capacitance 0.03 Up to 1,000 feet using 18 AWG twisted required for Serial Communication No T tapping of data wire REFERENCE relevant literature for full listing of available models and options POWER SUPPLY relevant literature for application details CLASS B WIRING Upload download DACT modem 12V10A Fire Alarm Control with dialer 5 Class B IDCs 2 Class B NACs red Mt Trim Kit Fire Alarm Control with dialer 10 Class B IDCs 4 Class B NACs red Mt Trim Kit upload download DACT modem dual line w 2X16 mounts to main assembly 2 cords included Cabinet red Ah Batteries Ah Batteries Ah Batteries Tie Module Requires 4 sq or 2 gang Polarity Module Requires or other listed FA enclosure Relay Module 5 Form C Config IDCs 1 5 or 6 10 common system indicators MFC A or other listed enclosure System Indicator Power Super Trouble and Grnd Single Gang trim included Zone Indicator 5 Red for 5 IDCs Gang trim included Zone Indicator 5 Bi Color Red Yellow for 5 IDCs Gang trim included Trim Plate 2 Gang Trim Plate 3 Gang Annunciator 10 Zone LEDs Red Yellow System Indicators for FX 10 4 sq box mnt Annunciator Bi Color LEDs Red w System Indicators for FX 10 only sq box mnt Drive Interface providing Indicators and Controls Red Battery Cabinet Amp Booster Power Supply Amp Booster Power Supply Ah Batteries Ah Batteries DETECTORS BASES Smoke Detector Base Smoke with Heat included detector photoelectric detector photoelectric w integral heat detector head only four wire 135 Fixed RoR Moisture Proof 194 Fixed RoR Moisture Proof Detector Detector DUCT SuperDuct Detector Tubes for SuperDuct Test Stations for SuperDuct Reset Lexan Double Action Pull Station Term Double Action Pull Station Term Reset Lexan Mount Box Red Manual Station backbox Horn Strobe Low Frequency cd Marked 24VDC Strobe Low Frequency 15 cd Marked 24VDC red Strobe 15 75 cd 16 33 VDC Marked Horn Strobe 15 75 cd 16 33 Red Marked Horn Constant or T3 16 33 VDC Red Marked Ring EG1 Series Red Strobe 15 115 cd Marked red Multi cd Strobe 95 177 cd red Horn Strobe 15 115 cd red Ceiling Multi cd Horn Strobe cd Marked red Weatherproof Strobe 110 cd Horn Strobe 110 cd Weatherproof Box CS405 strobes Weatherproof Box for CS405 Weatherproof Surface Box red Single Door Floor Mounted Double Door Floor Mounted Long Catch Plate Flush Wall Mnt Short Catch Plate Flush Wall Mnt Surface Wall Mounted SPDT relay Contact Rating Amps 115Vac and Coil Power Vac 24Vdc 115Vac or 230Vac DPDT relay Contact Rating Amps 115Vac and Coil Power Vac 24Vdc 115Vac or 230Vac SPDT relay Contact 10 Amps 115Vac and Coil 24 Vac 24Vdc or 115Vac complete product specifications and ordering information see Data Sheet FX Series Conventional Fire Alarm Control Panels appliance circuit NAC appliance circuit NAC listed 15 k listed 15 k mA AUX 1 2 or signaling circuit booster or NAC resistor power fail Line Ratings Relay Current Size 2 Installation AMP BOOSTER AMP BOOSTER 50 60Hz 390 watts 50 60Hz 580 watts nominal max total all NACs nominal max total all NACs Amps 30Vdc individually configurable outputs can replace NACs 2 3 or 4 as auxiliary outputs mA dedicated auxiliary for use with E NAC module to 24 Amp hours with external battery cabinet p n BC 1R 24Vdc from an existing NAC Booster Internal Supervisory Amp Hours 2 of 12V10A in cabinet 32 to 120 0 to 49 0 to 93 non condensing 32 Class B or 2 Class A California rate 3 3 3 temporal follow installed panel NAC Wiring Signal remote modules 6 shows the maximum number of devices that you can install the remote module communication bus Refer to the installation provided with the remote module for mounting and wiring Wiring diagrams are also provided in Appendix C relevant literature for application details 6 Remote module bus block diagram BUS group 1 to 5 to 10 to 5 to 10 group 2