Kidde K85001-0183 -- Single Action Pull Stations

File Preview
File Preview
Click below to download for free

File Data

Name kidde-k85001-0183-single-action-pull-stations-7851246390.pdf
Type PDF
Size 731.06 KB
Downloads

Text Preview

KIDDE Catalog u Conventional Initiating Fire Stations Series Kidde Cat No 276B 277B series noncoded fire alarm are contemporary styled Lexan stations and are flexibly to meet a wide variety of application requirements and sequences Cat No 276B series are single action stations with terminals field wiring connections Cat No 277B series are also single action stations but use 6 wire leads for field wiring connections types are available with single or double pole alarm contacts can be normally open normally closed or a combination both Either a key or tool depending on station selected is to reset mechanism See specification chart for specific numbers and features semi flush mounting use a standard North American 4 inch box with single gang plaster cover having an overall depth of 2 1 4 inches 57mm For surface mounting use surface back box Features Single action models Single or double pole contacts Terminals or wire leads for field connections Pre signal or general alarm operation Key lock or tool reset Break glass operation Surface or semi flush mounting Red finish Contemporary styling Rugged LEXAN construction Latch action until reset 1 of 4 D A T A S H E E T K85001 0183 to be used for installation purposes Issue 1.1 that saves livesfirealarmresources com Specifications Ratings Alarm Switch Keyswitch Pole Pole Amps 30 Vac Resistive Load Amps 28 Vdc Resistive Load Amps 30 Vac Resistive Load Amps 28 Vdc Resistive Load Kit for use in stations connected to smoke detector Housing Lexan 940 With White Letters lb 0.4 kg of Glass Rods Reset Key Supplied with all Key Reset Stations Alarm key Must be ordered separately Back Box Red These devices will not operate without electrical power As fires cause power interruptions we suggest you discuss further safeguards your local fire protection specialist initiate an alarm and break the glass rod pull down on the marked for Fire alarm handle latches in the pulled position until the station is reset To reset the station is opened using a Cat No key supplied with the station or a tool the toggle switch restored to it normal position the break glass rod is replaced the station is reclosed For presignal type stations the general can be initiated by authorized personnel from any operated by inserting Cat No 276 K2 key into the keyswitch behind alarm handle and turning it clockwise Specifications and install where indicated on plans Cat No Select one the following 276B series single action manual stations with screw terminals 277B series single action manual stations with 6 inch 150mm leads connection of installation wiring All stations shall be of the break glass type stations shall be constructed of red lexan with white raised The alarm handle shall be marked FOR FIRE to simple concise instructions for activation of station by the public the alarm handle shall break a glass rod and activate a switch which shall cause the handle to latch in the alarm Momentary push button type switches shall not be To reset the station it shall be necessary to open the using select one a key a special tool restore the toggle to its normal position and replace the glass rod shall be UL listed 2 of 4 D A T A S H E E T K85001 0183 to be used for installation purposes Issue 1.1 for optional resistor kit 276 R No 276B With Information Connections Contacts Reset Alarm Ac Pull 3 of 4 D A T A S H E E T K85001 0183 to be used for installation purposes Issue 1.1 that saves lives us 888.244.9979 Option 4 kidde esfire com kidde fire carrier com is a Carrier brand Town Center Pkwy FL 34202 2020 Carrier rights reserved 4 of 4 D A T A S H E E T K85001 0183 to be used for installation purposes Issue 1.1

Related Files