Kidde K85001-0305 -- Harsh Environment Strobes

File Preview
File Preview
Click below to download for free

File Data

Name kidde-k85001-0305-harsh-environment-strobes-2659017834.pdf
Type PDF
Size 804.42 KB
Downloads

Text Preview

Harsh Environment 7A 8A 8A Series strobes are specially designed for use with compatible safety communication and control equipment to alert the impaired of a life safety event Strobes are available 15 cd 15 75 cd and 110 cd effective flash intensity They fully compatible with Genesis signals Series strobes exceed UL synchronization requirements 10 milliseconds other over a two hour period when used a separately installed EG1M Signal Master or GSA CC1S Module or when powered by suitably enabled power supplies and control panels flash from 4MS Series strobes can be noticed from almost position in the room corridor or large open space 4MS strobes are UL 1971 listed with both wall and ceiling cd ratings see Specifications This is useful in areas the Authority Having Jurisdiction AHJ permits ceiling strobes Series strobes are designed for 16 to 33 Vdc operation must be connected to signal circuits that output a constant pulsed voltage A diode is used to allow full signal circuit and polarized connections are made to terminals that up to 12 AWG 2.5mm wire strobe front plate is of steel construction finished with durable epoxy polyester powder coat paint Series Features UL 1971 listed synchronizing strobe strobes synchronize to the latest UL 1971 when used with a synchronization source Genesis compatible Genesis and Integrity strobes on the same circuit meet 1971 synchronization requirements when used with an control module Approved for public and private mode applications 1971 listed as signaling devices for the hearing impaired UL 1638 listed as protective visual signaling appliances Rugged red or white steel front plate for outdoor or harsh environments Rated for wall or ceiling installation Field changeable field markings language or standard marking is easily changed optional LKW and LKC series lens kits Fits 4 inch square flush box for retrofit and renovation projects UL ULC rated outdoor option 1 of 4 D A T A S H E E T K85001 0305 to be used for installation purposes Issue 1.1 Catalog u Strobes Horns Bells Chimes09 29 20Technology that saves livesfirealarmresources com The installation of visible signals are subject to national and local standards codes and ordinances your Authority Having Jurisdiction for device installation requirements application standards and minimum performance specifications The flash intensity of some visible signals may not be adequate alert or waken occupants in the protected area Research indicates the intensity of strobe needed to awaken 90 of sleeping persons is 100 cd Kidde recommends that strobes in sleeping rooms rated at least 110 cd These devices will not operate without electrical power As frequently cause power interruptions further safeguards such as power supplies may be required strobes are UL 1971 listed for use indoors as wall mounted notification appliances for the hearing impaired codes require strobes to be used where ambient noise exceed specified levels where occupants use hearing and in areas of public accommodation Consult with Authority Having Jurisdiction for details part of the Enhanced Integrity line of products 4MS Series exceed UL synchronization requirements within 10 other over a two hour period when used with a source Synchronization is important because a portion of the population have a condition which may cause to become disoriented from multiple random flashes of light strobes minimize this risk strobes are fully compatible with Kidde Genesis signals Current RMS Vdc Vfwr cd Vdc Vfwr cd Volts direct current regulated and filtered Volts full wave rectified cd cd cd cd Draw Notes and Comments Current values are shown in mA UL Nameplate Rating can vary from Typical Current due to measurement and instruments used Kidde recommends using the Typical Current for system design including NAC Power Supply loading and voltage drop calculations Use the 16 Vdc RMS current ratings for filtered power supply and battery AH Use the 16 Vfwr RMS current ratings for unfiltered power supply Fuses circuit breakers and other overcurrent protection devices are typically for current in RMS values Most of these devices operate based upon the affect of the current flowing through the device The RMS current deter the heating affect and therefore the trip and hold threshold for devices Wiring 24 Vdc Strobe an end of resistor on the device resistor with panel Listed dc Alarm Panel circuit 2 of 4 and Mounting models fit to a standard flush mounted North American four electrical box 1 1 2 inch 38 mm deep minimum Optional weatherproof surface mount boxes are available The must be connected to signal circuits which output a con not pulsed voltage Kidde recommends that these strobes be installed in accordance with the latest recognized edition national and local fire alarm codes mm VIEW MOUNTED Lens Marking LKW or LKC Series mm Philip screws are provided secure unit onto electri box Plastic Caps are pro for indoor mounting mm mm D A T A S H E E T K85001 0305 to be used for installation purposes Issue 1.1 Distribution cd 3A Series Strobes cd 5A Series Strobes cd 4A Series Strobes cd 7A Series Strobes cd 8A Series Strobes cd 3A Series Strobes cd 4A Series Strobes cd 8A Series Strobes Output Output Output Output Output e grees e grees e grees e grees e grees 20 10 100 Output e grees Output e grees Output e grees 20 30 100 Output Output Output Output Output Output Output min min min min min min min Output Sources MEG1M RM GSA CC1S GSA MCC1S MIRBPS6 MIRBPS10 Operating Volts Number 1638 ULC S526 Strobe Output 1971 Rated Strobe Flash Rate Environment Markings Connections Tube Enclosure Plate Finish Listings only

Related Files