Kidde K85001-0317 -- Integrity Re-entrant Speaker and Speaker-Strobe

File Preview
File Preview
Click below to download for free

Text Preview

Re entrant and Series Integrity Series life safety and mass notification emergency ECS MNS re entrant speakers and speaker are high quality appliances for emergency voice communi as well as alert and alarm tone signals rugged plastic housing is made from durable and fire re high impact plastic with a slightly textured surface Hous are rated for outdoor use and are available in red or white ingenious mounting plate firmly holds the device in place a single screw This ensures quick and attractive installation separate trim plate is not required Speaker terminals accept up 12 AWG 2.5mm wire for polarized connections Strobe con are made to color coded wire leads safety strobes are shipped with standard wall mount style FIRE markings Where ceiling orientation other languages or dif lens markings are required Kidde offers optional LKW and series Lens Marking Kits These optional lens markings simply on to the strobe Consult Kidde for availability of special lens strobes are designed for 16 to 33 Vdc operation and be connected to signal circuits that output a constant not voltage A diode is used to allow full signal circuit supervi Features UL 1971 listed synchronizing strobe strobes synchronize to the latest UL 1971 require when used with a synchronization source Genesis compatible Genesis and Integrity strobes on the same circuit meet UL synchronization requirements when used with an external module Listed for public and private mode applications 1971 listed as signaling devices for the hearing impaired UL 1638 listed as protective visual signaling appliances 98 dBA Output efficency driver produces a loud 98 dBA at 15 watts Multiple Output Taps 25 or 70 Volt Models to select for 2 4 8 and 15 watt operation Integrity are supplied with a DC Blocking Capacitor for audio supervision Outdoor rated red or white Noryl front plate is ideal for outdoor indus or harsh environments Field changeable field markings language or standard marking is easily changed optional LKW wall orientation and LKC ceiling orienta lens kits 1 of 6 D A T A S H E E T K85001 0317 to be used for installation purposes Issue 1.2 Catalog u Speakers Telephones04 02 20Technology that saves livesfirealarmresources com The installation of visible and audible signals are subject to national and local standards codes and ordinances your Authority Having Jurisdiction for device installation requirements application standards and minimum performance specifications Integrity speakers include a DC blocking capacitor to allow supervision of the audio distribution circuit Models for VRMS and 70 VRMS circuits are available Wattage taps from 2 to 15 W provide on site suggested sound pres level for each signal zone used with alert or signals is a minimum 15 dB above the average sound level or 5 dB the maximum sound having a duration of at 60 seconds whichever greater This is measured 5 1.5 m above the floor 1.5m Radius 3.05m Radius Sound Output Distribution the distance from signal to the ear will theo cause a 6dB reduc in the received sound level The actual ef depends on the acoustic properties of materials in the space the power output of a device e g a speaker from 1W to will increase the sound pressure level by 3dBA measured in anechoic clear strobes are UL 1971 listed for use indoors as wall or mounted public mode notification appliances for the hearing Prevailing codes require strobes to be used where ambi noise conditions exceed specified levels where occupants hearing protection and in areas of public accommodation with your Authority Having Jurisdiction for details part of the Enhanced Integrity line of products INT Series exceed UL synchronization requirements within10 over a two hour period when used with a source Synchronization is important in order to epileptic sensitivity strobes are fully compatible with Kidde Genesis signals These devices will not operate without electrical power As frequently cause power interruptions further safeguards such as power supplies may be required Wiring strobe must be connected to signal circuits which output a constant not pulsed 24 Vdc voltage Depending on the model the must be connected to either 25 or 70 V audio circuits 33 of line resistor return to control of line resistor return to control 2 of 6 D A T A S H E E T K85001 0317 to be used for installation purposes Issue 1.2 Distribution Patterns 1971 WALL MOUNTED STROBE LIGHT OUTPUT cd 5A Series Strobes cd 7A Series Strobes cd 3A Series Strobes cd 4A Series Strobes cd 8A Series Strobes Output e grees Output e grees Output e grees Output e grees Output e grees 20 30 100 Output Output Output Output Output min min min min min Current values are shown in mA Fuses circuit breakers and other overcurrent protection devices are typically for current in RMS values Most of these devices operate based upon heating affect of the current flowing through the device The RMS current the heating affect and therefore the trip and hold threshold for those Current RMS Vdc Vfwr cd cd Vdc Vfwr Volts direct current regulated and filtered Volts full wave rectified cd cd cd cd cd cd Level Output W W W W UL 1480 1480 level output notes All values shown are dBA measured at 10 feet 3.01m UL1480 values measured in reverberation room Average values are measured in anechoic chamber 3 of 6 D A T A S H E E T K85001 0317 to be used for installation purposes Issue 1.2 and Mounting models fit to flush mounted Kidde box Catalog Number 960A 4SF Optional flush trims are not required For surface mount use custom indoor and outdoor surface boxes painted in color matched red or white epoxy Kidde recommends that these Life and ECS MNS speaker strobes always be installed in accordance with the latest recognized edition of national and local codes Mount Box Steel 3 8 111 mm square No 960A 4SF Series Signal 1 2 mm 1 2 mm x 7 16 11 mm Screw Supplied Screw others mm 1 2 3 4 Knockout Bottom Back 5 8 mm 9 16 mm 5 8

Related Files