Kidde K85001-0642 -- Genesis Wall Speakers and Speaker-Strobes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85001-0642-genesis-wall-speakers-and-speaker-strobes-6139527480.pdf |
---|---|
Type | |
Size | 1.65 MB |
Downloads |
Text Preview
Wall Speakers G4 Series Genesis line of life safety and emergency communications and speaker strobes combine high performance output a low profile design to deliver a life safety audio solution that versatile as it is effective Protruding no more than one inch the wall these appliances blend inconspicuously with any amber or blue lenses ALERT or FIRE markings and red white housing colors ensure there is a device for every applica including mass notification and emergency communications feature selectable wattage taps while speaker strobes for both wattage and light output levels to be configured in the Both settings remain clearly visible even after final installa which allows devices to be easily fine tuned to achieve maxi benefit in exchange for the lowest possible system overhead fidelity models meet the NPFA 520 Hz requirements for newly commercial sleeping areas They also produce crisp voice audio output that is highly intelligible over large areas Genesis speakers include a DC blocking capacitor to allow supervision of the audio distribution circuit Models for VRMS and 70 VRMS audio circuits are available With their sealed construction these speakers are extra durable and provide audibility Specifications Section for listings details Features High Fidelity 520 Hz speaker models available frequency output meets NFPA standards for newly con commercial sleeping areas increases sound fidelity audio intelligibility Unique low profile design The most compact UL ULC listed speaker strobe available Ultra slim protrudes a mere one inch from the wall Attractive appearance no visible mounting screws Field configurable no need to remove the device 1 or 2 watt operation and selectable candela output with convenient switches that remain visible even after the unit is installed Mass Notification models available with and blue lenses Unparalleled performance loud 90 dBA output ensures clear crisp audio Exclusive FullLight strobe technology produces even light distribution Precision timing electronics meet tough synchronizing standards for strobes when used with compatible modules Optional field configurable temporal strobe output 25 Vrms and 70 Vrms models available all supplied with a DC blocking capacitor for audio circuit supervision Easy to install behind the signal for extra wire no extension ring Fits all standard 4 inch square electrical boxes with plenty of or trim plate needed 18 12 AWG terminals ideal for long runs or using existing wiring 1 of 6 D A T A S H E E T K85001 0642 to be used for installation purposes Issue 2.2 Catalog u Speakers Telephones12 14 21Technology that saves livesfirealarmresources com Application suggested sound pressure level for each signaling zone with alert or alarm signals is a minimum of 15 dB above the ambient sound level or 5 dB above the maximum sound having a duration at least 60 seconds is greater This measured 5 feet 1.5 m the floor in anechoic chamber Sound Output dBA two watts the distance from signal to the ear will cause a 6 dB in the received pressure level The effect depends on acoustic properties materials in the space the power output a device e g a speaker 1W to 2W will in the sound pressure by 3dBA 1.5m 3.05m Series Cone Speaker strobe speakers are available in combination with a UL 1971 listed light for indoor wall mounted public mode notification ap These audible visible appliances should be installed in with guidelines established for visible strobe devices Fidelity Models G4HF Series High Fidelity appliances provide highly intel voice audio output They are also effective in areas subject high levels of ambient noise These appliances are approved for in sleeping areas under conditions described below Room Applications G4HF Series High Fidelity appliances are ideal for hotels and other residential occupancies where audible must meet the 520 Hz signaling characteristics required by 72 sleeping areas always ensure that the wattage tap of the is set sufficiently high so that the sound pressure reaches least 75 dBA fast at the pillow appliances are part of an end to end audio system ap for use in sleeping areas when used in conjunction with audio hardware and a factory supplied 520 Hz tone the System Compatibility List for other 520 Hz signaling Speakers driven by third party audio systems not UL approved for use in sleeping rooms Application clear lensed strobes are UL 1971 listed for use indoors as public mode notification appliances for the hearing Prevailing codes require strobes to be used where ambi noise conditions exceed specified levels where occupants use protection and in areas of public accommodation UL colored lensed strobe lights are available for mass no applications Consult with your Authority Having Jurisdic for details used with a compatible Kidde synchronization source all xenon based strobes audible units and combination remain fully synchronized indefinitely This exceeds UL synchronization requirements of 10 milliseconds over a two period Strobe light synchronization is important in order to issues with people that have Photosensitive Epilepsy Notification Applications mass notification bring the same life safety and unobtrusive to mass notification Standard mod are available with clear and blue lenses They ideal for applications that differentiation between safety and mass notification alerts See the Ordering Information for housing marking options Configuration speakers may be set for 1 or 2 watt operation The setting is visible through a small window on the bottom the device and is changed by simply sliding the switch until the setting appears in the window The speaker does not have be removed to change the wattage speaker strobes feature selectable candela output The setting is visible through a small window on the bottom of device and is changed by simply sliding the switch until the setting appears in the window The speaker strobe does have to be removed to change the output the Candela Switch and the switch to set desired operation change strobe to temporal mode cut JP1 switch switch View speaker strobes may also be configured for temporal This battery saving feature is intended for private mode only To set the device for temporal flash snip the circuit as shown in the Jumper Locations diagram above These devices will not operate without electrical power fires frequently cause power interruptions we suggest you dis further safeguards with your local fire protection specialist 2 of 6 D A T A S H E E T K85001 0642 to be used for installation purposes Issue 2.2 and Mounting models are intended for indoor wall mounted applications only and speaker strobes are flush mounted to a North 4 square electrical box 21 8 54 mm deep or a Euro 100 mm square box Signals may be surface mounted to a surface mount box see ordering information for details tabs at the top of the signal unlock the cover to facilitate The shallow depth of Genesis devices leaves room the signal for extra wiring Once installed with the cover in no mounting screws are visible electrical box EG4B color surface mount box recommends that these speaker strobes always be installed accordance with the latest recognized edition of national and lo codes Refer to installation sheet for mounting height informa wiring is connected to Genesis signals with terminals that ac 18 to 12 AWG 0.75 mm to 2.5 mm wiring output cent of UL rating versus angle Of Candela H Spec Of Candela V Spec