Kidde K85001-0655 -- Intelligent Detector Diagnostic Tool
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85001-0655-intelligent-detector-diagnostic-tool-6803149257.pdf |
---|---|
Type | |
Size | 1.09 MB |
Downloads |
Text Preview
Intelligent Detector Tool KI HDT is a compact and easy to use diagnostic tool that installation and troubleshooting Kidde device loops and devices The KI HDT is a hand held unit and features touch screen that makes it possible for the operator to manipu test and monitor the device loop in the field using live data in time KI HDT comes with PC compatible software that generates reports for archiving or further diagnostic analysis Data and stored on the KI HDT may be downloaded from the directly to a laptop or desktop computer by means of a USB or it may also be saved to a USB Flash drive for later use blocks on top of the unit provide easy connection of field while USB 2.0 and Micro B ports provide an interface for exchange and power The KI HDT is powered by a recharge lithium ion battery Features Manipulates tests and monitors device loop and connected and modules Ideal for system verification and troubleshooting Compact easy to use for factor Bright touch screen graphical user interface Easy access terminal blocks for field wiring Rechargeable lithium ion battery Includes PC software for report generation and data manage V1.8 brings increased diagnostics for locating wiring faults 1 of 4 D A T A S H E E T K85001 0655 to be used for installation purposes Issue 1 Catalog u Intelligent Initiating DevicesTechnology that saves livesfirealarmresources com KI HDT is ideal for verifying new projects troubleshooting installations or testing retrofits It can be used to initialize device loop before connecting to a control panel or it can be for diagnosis and troubleshooting after loop connections are to the controller operation the KI HDT performs the following functions Initializes the loop i e identifies all devices connected to the Restores the loop Performs Map Analysis on detectors and modules contact and map consistency and identifies failed units Performs Dirty Level analysis on photo detectors and identifies that require cleaning Allows the user to program new device address to a detector module Perform maintenance on a single detector or module Reinitialize the device address of detectors or modules on a to zeros Single device diagnostics Loop history etc details concerning the capabilities and operation of the KI consult KI HDT Operations user guide P N 3102424 EN Position Block Position Block B T terminal block for A only KI HDT Main Menu displays high level testing and diagnostics initialize loop function enables the device to perform some ini actions such as resetting all devices and opening all isolators function uses the device serial number to assign new short read device address version numbers device types on the SLC and checks for ground fault on the SLC loop initialized data is stored in the Database Info page the display and can be accessed by pressing the Loop History Restore loop function closes all isolators and checks all device on the loop Analysis KI HDT provides two methods of investigating a new or exist loop installation These methods help pinpoint specific devices are causing map faults or have the potential to cause a future fault The map fault analysis function performs the following diagnostic tests Consistency map consistency function maps each device on the loop three times and compares the responses of all readings to see if there is a mismatch If a device is responding consistently it is flagged as failed and an is required Analysis contact analysis function tests the response mea by listening device s when the annunciating device activated The response is an indirect measurement of contact resistance and can be used to identify existing issues or devices that have the potential to cause issue in the future 2 of 4 D A T A S H E E T K85001 0655 to be used for installation purposes Issue 1 Level function is only associated with optical detectors It enables user to determine the dirty level of each optical detector on the After the successful execution of this function the KI HDT the old database of Dirty Levels and replaces it with the Dirty Level data Device History Device History displays data only when the single de Read EE Data function was performed The database stores single device Short Address SA Operation Hours OpHrs Last Alarm Bytes and Alarm Originator When there is no status N A is displayed on the Alarm Last Alarm Bytes and originator respectively Diagnostic Menu holds functions that enable a user to run on the devices connected to the loop The functions can be performed within the diagnostic menu screen Photo Function function normalizes writes the new clean air count into After cleaning the detector using the approved or method the user can connect the detector s back the loop and initiate this function to normalize the photo Device Function single device function allows a user to diagnose a single within a loop or outside a loop The single device consists of five sub functions that include Read EE Photo A D value Program Device Address Program date and Trouble Codes EEPROM Function Read EEPROM function is an advanced function that be requested by technical support or engineering Function function is useful if the user needs to reset all device on the loop to zero Maintenance Date function is useful when a user performs maintenance a photo detector and needs to update the maintenance register on the detector Codes Trouble Code function enables the user to understand trouble condition the possible cause and possible to resolve the trouble Trouble Codes are displayed the Restore Loop execution Settings screen displays current date and time The KI HDT to be connected to the computer software to sync the time date The interface and GUI board versions along with the status loop output voltage and current are displayed History Loop History function takes the user to the Stored Data Screen this screen shows the device information stored in memory of the KI HDT If no actions Initialize map analysis have been performed previously no data is displayed in the PC Software KI HDT comes with PC compatible software that may be for firmware updates as well as importing data from the for saving to the PC user can import three categories of data Device EEPROM Data KI HDT Report Data The KI HDT Report contains all the information the dirty level for each photo detector the loop and mapping data Single Device Data This function imports the single history data saved in the KI HDT internal memory the KIDDE Diagnostic Tool software details concerning diagnostic and mapping capabilities of the software consult KI HDT Operations user guide 3 of 4 D A T A S H E E T K85001 0655 to be used for installation purposes Issue 1 Information Diagnostic Tool Battery for KI HDT KI HDT ships with the following documentation and accessories USB flash drive Includes PC software and user guide USB charging cable USB 2.0 A male to Micro B cable AC USB charging adapter 10 position terminal connector block 4 position terminal connector block KI HDT Installation sheet KI HDT Operations user guide Lithium ion battery that saves lives us 888.244.9979 Option 4 kidde esfire com kidde fire carrier com is a Carrier brand Town Center Pkwy FL 34202 2020 Carrier rights reserved 4 of 4 D A T A S H E E T K85001 0655 to be used for installation purposes Issue 1