Kidde K85001-0659 -- Intelligent Smoke Detector, Rotary-Addressed

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent Smoke KIR PD optical smoke detector brings advanced sensing to a practical design that increases efficiency saves time cuts costs and extends life safety and property capabilities Continuous self diagnostics ensure reli over the long haul while environmental compensation helps maintenance costs all KIR Series detectors the KIR PD is an intelligent device gathers analog information from its optical sensor converting data into digital signals To make an alarm decision the detec on board microprocessor measures and analyzes sensor and compares this information to historical data Digital remove signal patterns that are not typical of fires thus virtu eliminating unwanted alarms Standard Features Some features described here may not be supported by control systems Check your control panel Installation and Guide for details Next Generation Optical Smoke Sensing Technology Wide 0.53 to 3.94 ft 1.7 to 12.35 m smoke obscuration Uses Existing Wiring Up To 250 Total Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Five Sensitivity Settings Non Volatile Memory Rotary Addressing Identification of Dirty or Defective Detectors Automatic Day Night Sensitivity Adjustment Bicolor Green Red Status Led Standard Relay Fault Isolator and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification 1 of 4 A T A S H E E T K85001 0659 to be used for installation purposes Issue 1.1 Catalog Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com KIR PD detects extremely small particles of combustion and an alarm at the first sign of smoke Thanks to its high forward scattering reflective response technology photoelectric smoke sensor responds quickly and reliably to wide range of fire types espe cially slow burning fires fuelled by typically found in modern multi use buildings KIR PD is compatible with FX Series intelligent panels mounting bases have wiring terminals that are acces from the after mounting the base to the electrical The bases mount to North American 1 gang boxes and to inch or 4 inch octagon boxes 1 inches 38 mm deep They mount to European BESA and 1 gang boxes with 60.3 mm centers The KI SB4 KI RB4 and KI IB4 mount to North 4 inch sq electrical boxes in addition to the above They include the GSA TS4 Trim Skirt which is used to the ears on the base The KI ABST mounts to a inch square box only Series detector bases mount North American 1 gang boxes inch or 4 inch octagon and to 4 inch square elec boxes 1 1 2 inches 38 mm They mount to European and 1 gang boxes with 60.3 fixing centers See mounting installation and wiring for information tab Indicator and reporting technology microprocessor in each detector provides additional benefits Self diagnostics and History Log and Fast Stable Communica and History Log Each KIR Series detector runs self checks to provide important maintenance in The results of the self check are automatically updated permanently stored in the detector non volatile memory Stable Communication On board intelligence means less needs to be sent between the detector and the loop Other than regular supervisory polling response the only needs to communicate with the loop controller when has something new to report Maintenance detector automatically identifies when it is dirty or defective causes a detector message The detector sensitiv measurement can also be transmitted to the loop controller A report may be printed to satisfy NFPA sensitivity mea which must be conducted at the end of the first year every two years thereafter user friendly maintenance program shows the current state each detector and other pertinent messages Single detectors be turned off temporarily from the control panel Availability of features is dependent on the fire alarm system used Base Base Base Base LED LED The remote LED connects to the KI SB or KI SB4 Base only It features a North American size 1 gang faceplate with a white finish and red alarm LED Skirt Supplied with 4 inch bases it can also be ordered to use with the other bases to help hide surface imper not covered by the smaller bases Bases KIR Series sounder bases are designed for use localized or group alarm signaling is required KI ABST bases provide sounder capability to KIR Series heat smoke detectors KI ABLT bases provide 520 Hz low frequency sounder capa to KIR Series smoke and heat detectors The KI ABLT suitable for applications requiring low frequency audible Addressing is made easy through the rotary dials located on the of the detector head Use a screwdriver to adjust the TENS switch 0 through 12 to set the 10s digit and the ONES switch to set the digit 0 through 9 The control panel will any duplicate addresses 5 9 screwdriver here device address 21 set TENS rotary switch to 2 and set ONES rotary switch to 1 2 of 4 A T A S H E E T K85001 0659 to be used for installation purposes Issue 1.1 Sounder Bases Fire Mode AB4G LF sounder bases Setting High for dB cuts SIG OUT DATA DATA Mode Fire jumper for plus CO Setting Temporal jumper for Vdc in power supply previous base in KIR Device Control or previous device 24 Vdc out next base or EOL relay out next KIR Series device Cautions This detector does not operate without electrical power As frequently cause power interruption discuss further with the local fire protection specialist This detector does not sense fires in areas where smoke reach the detector Smoke from fires in walls roofs on the opposite side of closed doors may not reach the Photoelectric detectors have a wide range of fire sensing and are best suited for detecting slow smolder fires In Canada install according to CAN ULC S524 Standard for Installation of Fire Alarm Systems CSA C22.1 Canadian Code and the local authority having jurisdiction Wiring detector mounting bases accept 18 AWG 0.75mm2 16 14 AWG 1.5mm2 and 12 AWG 2.5mm wire sizes 16 AWG 1.0mm2 and 18 AWG 0.75mm2 are preferred ease of installation Detector Base KI SB KI SB4 is the basic mounting base Kidde KIR Series detectors GSA LED Remote LED is by this LED resistance wire not exceed Ohms Term Description 1 Not Used 2 DATA IN OUT 3 Not Used 4 DATA IN 4 Remote LED 5 Remote LED 6 Not Used 7 DATA OUT IN IN Signature Controller Previous Device OUT OUT Next Device Detector Base KI IB KI IB4 base includes a built in line fault isolator for use on Class A A detector must be installed for it to operate The isolator does not support the GSA LED Remote LED isolator operates as follows a short on the line causes all iso to open within 23 msec Term Description 1 Not Used 2 DATA IN OUT 3 DATA IN 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used at 10 msec intervals on one side the Class A nearest the loop the isolators to provide the isolator down the with power when the isolator next the short closes it reopens within 10 process repeats beginning on the side of the loop controller Detector Base KI RB KI RB4 base includes a relay Nor Open or Normally Closed is selected during The dry contact is for 1 amp pilot duty Vdc The relay position is to avoid accidentall

Related Files