Kidde K85001-0660 -- Intelligent Multisensor Smoke and Heat Detector, Rotary-Addressed
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85001-0660-intelligent-multisensor-smoke-and-heat-detector-rotary-addressed-3618425097.pdf |
---|---|
Type | |
Size | 1.08 MB |
Downloads |
Text Preview
Intelligent Smoke Heat Detector KIR PHD detector brings advanced multisensor technology a practical design that increases efficiency saves installation cuts costs and extends life safety and property protection Continuous self diagnostics ensure reliability over the while environmental compensation helps reduce main costs KIR PHD provides an optical smoke sensor and a rate of rise sensor with a fixed temperature setting Together these sen efficiently detect smoldering fires as well as fast flaming fires all KIR Series detectors the KIR PHD gathers analog in from its sensing elements and converts this data into signals To make an alarm decision the detector on board measures and analyzes smoke and heat sensor and compares this information to historical data Digital remove signal patterns that are not typical of fires thus virtu eliminating unwanted alarms Features Some features described here may not be supported by control systems Check your control panel Installation and Guide for details Next generation detection technology Integrates optical smoke with rate of rise heat sensing Wide 0.53 to 3.94 ft 1.7 to 12.35 m smoke obscuration Uses existing wiring Sensor Markings Provide Easy Testing Identification Up To 250 Total Addresses Per Loop Two levels of environmental compensation Two levels of dirty detector warning Five sensitivity settings Non volatile memory Convenient rotary addressing Environmental compensation Automatic day night sensitivity adjustment Bicolor green red status LED Standard relay fault isolator and audible mounting bases 1 of 4 A T A S H E E T K85001 0660 to be used for installation purposes Issue 1.1 Catalog Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com detection KIR PHD detects extremely small particles of combustion and an alarm at the first sign of smoke Thanks to its high forward scattering reflective response technology photoelectric smoke sensor responds quickly and reliably to wide range of fire types espe cially slow burning fires fuelled by typically found in modern multi use buildings Addressing is made easy through rotary dials located on the back of detector head Use a screwdriver adjust the TENS rotary switch 0 12 to set the 10s digit and ONES rotary switch to set the 0 through 9 The control panel identify any duplicate addresses 5 9 screwdriver here detection on board rate of rise heat sensor provides a 15 per minute for the detection of fast developing fires while providing a 135 57.2 fixed detection threshold The sensors monitor the temperature of the air and determines an alarm should be initiated KIR PHD is compatible with FX Series intelligent panels Series detector bases mount North American 1 gang boxes inch or 4 inch octagon and to 4 inch square elec boxes 1 1 2 inches 38 mm They mount to European and 1 gang boxes with 60.3 fixing centers See mounting installation and wiring for information tab Indicator Maintenance maintenance regular or selected for proper detector should be planned to meet the requirements of the Au Having Jurisdiction AHJ Refer to current NFPA 72 NFPA and ULC CAN ULC 536 standards Sensor Sensitivity KIR PHD determines when its optical sensor is dirty or and can transmit sensitivity data to the loop controller sensitivity report can also be printed to satisfy NFPA sensitivity which must be conducted at the end of the first and every two years thereafter The availability of maintenance depends on the fire alarm system used for device address 21 set TENS rotary switch to 2 and the ONES rotary switch to 1 and reporting technology microprocessor in each detector provides additional benefits Self diagnostics and History Log and Fast Stable Communica and History Log Each KIR Series detector runs self checks to provide important maintenance in The results of the self check are automatically updated permanently stored in the detector non volatile memory Stable Communication On board intelligence means less needs to be sent between the detector and the loop Other than regular supervisory polling response the only needs to communicate with the loop controller when has something new to report mounting bases have wiring terminals that are acces from the after mounting the base to the electrical The bases mount to North American 1 gang boxes and to inch or 4 inch octagon boxes 1 inches 38 mm deep They mount to European BESA and 1 gang boxes with 60.3 mm centers The KI SB4 KI RB4 and KI IB4 mount to North 4 inch sq electrical boxes in addition to the above They include the GSA TS4 Trim Skirt which is used to the ears on the base Sounder bases mount to a inch square boxes only Base Base Base Base LED LED The remote LED connects to the KI SB or KI SB4 Base only It features a North American size 1 gang faceplate with a white finish and red alarm LED Skirt Supplied with 4 inch bases it can also be ordered to use with the other bases to help hide surface imper not covered by the smaller bases Bases KIR Series sounder bases are designed for use localized or group alarm signaling is required KI ABST bases provide sounder capability to KIR Series and heat detectors KI ABLT bases provide 520 Hz low frequency sounder capa to KIR Series smoke and heat detectors The KI ABLT suitable for applications requiring low frequency audible 2 of 4 A T A S H E E T K85001 0660 to be used for installation purposes Issue 1.1 Sounder Bases Fire Mode sounder bases Setting High for dB cuts SIG OUT DATA DATA Mode Fire jumper for plus CO Setting Temporal jumper for Vdc in power supply previous base in KIR Device Control or previous device 24 Vdc out next base or EOL relay out next KIR Series device Cautions This detector does not operate without electrical power As frequently cause power interruption discuss further safe with the local fire protection specialist This detector does not sense fires in areas where smoke or cannot reach the detector Smoke or heat from fires in roofs or on the opposite side of closed doors may not the detector Photoelectric detectors have a wide range of sensing capabili and are best suited for detecting slow smoldering fires heat sensor in this device provides a source of supplemen information The heat sensor by itself does not provide life protection In Canada install according to the CAN ULC S524 Standard the Installation of Fire Alarm Systems the CSA C22.1 Cana Electrical Code and the local authority having jurisdiction Upon completion of the original installation and following any or additions to the system perform a calibrated test per NFPA code KIR Series devices can perform test and the panel can generate a system sensitivity report Wiring detector mounting bases accept 18 AWG 0.75mm2 16 14 AWG 1.5mm2 and 12 AWG 2.5mm wire sizes 16 AWG 1.0mm2 and 18 AWG 0.75mm2 are preferred ease of installation Detector Base KI SB KI SB4 is the basic mounting base Kidde KIR Series detectors GSA LED Remote LED is by this LED resistance wire not exceed Ohms Term Description 1 Not Used 2 DATA IN OUT 3 Not Used 4 DATA IN 4 Remote LED 5 Remote LED 6 Not Used 7 DATA OUT IN IN Signature Controller Previous Device OUT OUT Next Device Detector Base KI IB KI IB4 base inc