Kidde K85001-0662 -- Intelligent Multisensor Smoke and CO Detector, Rotary-Addressed

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent Smoke CO Detector KIR PCD detector brings advanced multisensor technology a practical design that increases efficiency saves installation cuts costs and extends life safety and property protection Continuous self diagnostics ensures reliability over long haul while environmental compensation helps reduce costs KIR PCD provides a combination of optical detection for early detection of smoke with the added element of carbon sensing The result is a detector that pulls double duty monitoring the environment for signs of fire as well its invisible yet deadly companion carbon monoxide all KIR Series detectors the KIR PCD gathers analog informa from its sensing elements and converts this data into digital To make an alarm decision the detector on board mi measures and analyzes smoke sensor readings and this information to historical data Digital filters remove patterns that are not typical of fires thus virtually eliminating alarms The detector also analyzes the smoke sensor from the CO sensor to determine whether to initiate fire alarm a life safety CO alarm or both Features Some features described here may not be supported by control systems Check your control panel Installation and Guide for details optical smoke with carbon monoxide detection Next Generation Detection Technology Wide 0.53 to 3.94 ft 1.7 to 12.35 m smoke obscuration Sensor Markings Provide Easy Testing Identification Uses existing wiring Automatic device mapping Ground fault detection by module Up To 250 Total Addresses Per Loop Two levels of environmental compensation Two levels of dirty detector warning Twenty pre alarm settings Five sensitivity settings Non volatile memory Convenient rotary addressing Environmental compensation Automatic day night sensitivity adjustment Bicolor green red status LED Standard relay fault isolator and audible mounting bases 1 of 4 A T A S H E E T K85001 0662 to be used for installation purposes Issue 1 Catalog Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com detection KIR PCD detects extremely small particles of combustion and an alarm at the first sign of smoke Thanks to its high forward scattering reflective response technology photoelectric smoke sensor responds quickly and reliably to wide range of fire types espe cially slow burning fires fuelled by typically found in modern multi use buildings Detection CO detection such as that provided by the KIR PCD is mandated with increasing frequency in all types of com applications but particularly in occupancies such as hotels houses dormitories day care facilities schools hospitals living facilities and nursing homes Known as the CO is odorless tasteless and colorless It claims nearly 500 and results in more than 15,000 hospital visits annually KIR PCD detector is compatible only with the KIR Series Loop Series detectors mount to American 1 gang boxes inch or 4 inch octagon and to 4 inch square elec boxes 1 1 2 inches 38 mm They mount to European and 1 gang boxes with 60.3 fixing centers See mounting installation and wiring for information tab Indicator Maintenance maintenance regular or selected for proper detector should be planned to meet the requirements of the Au Having Jurisdiction AHJ Refer to current NFPA 72 NFPA and ULC CAN ULC 536 standards Sensor Sensitivity KIR PCD determines when its optical sensor is dirty or and can transmit sensitivity data to the loop controller sensitivity report can also be printed to satisfy NFPA sensitivity which must be conducted at the end of the first and every two years thereafter The availability of maintenance depends on the fire alarm system used Sensor Life CO sensor has a 10 year life from the date of manufacture or the control panel indicates a sensor end of life condition comes first When the sensor reaches its end of life the signals a TRBL ACT condition on the control Pressing the Details button on the control panel displays OF LIFE ACT providing verification that it is an end of life of the CO sensor This trouble remains active until the is replaced even if the panel is reset and reporting technology microprocessor in each detector provides additional benefits and History Log Automatic Device Mapping and Stable Communication and History Log Each KIR Series detector runs self checks to provide important maintenance infor The results of the self check are automatically updated and stored in the detector non volatile memory Device Mapping The loop controller learns where device serial number address is installed relative to other de on the circuit The mapping feature provides supervision of each installed location to prevent a detector from being reinstalled cleaning etc in a different location from where it was originally Stable Communication On board intelligence means less needs to be sent between the detector and the loop Other than regular supervisory polling response the only needs to communicate with the loop controller when has something new to report mounting bases have wiring terminals that are acces from the after mounting the base to the electrical The bases mount to North American 1 gang boxes and to inch or 4 inch octagon boxes 1 inches 38 mm deep They mount to European BESA and 1 gang boxes with 60.3 mm centers The KI SB4 KI RB4 and KI IB4 mount to North 4 inch sq electrical boxes in addition to the above They include the GSA TS4 Trim Skirt which is used to the ears on the base Sounder bases mount to a inch square boxes only Base Base Base Base LED LED GSA LED The remote LED connects to the KI SB KI SB4 Standard Base only It features a North American size plastic faceplate with a white finish and red alarm LED Trim Skirt Supplied with 4 inch bases it can also ordered separately to use with the other bases to help hide imperfections not covered by the smaller bases Bases KIR Series sounder bases are designed for use localized or group alarm signaling is required KI ABDT bases provide sounder capability to the KIR PCD when with a FX T3T4 Temporal Pattern Generator to separate CO and Fire TC3 tone patterns KI ABLT bases provide 520 Hz low frequency sounder capabil to the KIR PCD when used with a FX T3T4 Temporal Pattern to separate CO TC4 and Fire TC3 tone patterns KI ABLT is suitable for applications requiring low frequency tones 2 of 4 A T A S H E E T K85001 0662 to be used for installation purposes Issue 1 Wiring detector mounting bases accept 18 AWG 0.75mm2 16 14 AWG 1.5mm2 and 12 AWG 2.5mm wire sizes 16 AWG 1.0mm2 and 18 AWG 0.75mm2 are preferred ease of installation Detector Base KI SB KI SB4 is the basic mounting base Kidde KIR Series detectors GSA LED Remote LED is by this LED resistance wire not exceed Ohms Sounder Bases Fire Mode AB4G AB4G LF sounder bases Setting High for dB cuts DATA DATA Term Description 1 Not Used 2 DATA IN OUT 3 Not Used 4 DATA IN 4 Remote LED 5 Remote LED 6 Not Used 7 DATA OUT IN IN Signature Controller Previous Device OUT OUT Next Device Vdc in power supply previous base in KIR Device Control or previous device Mode Fire jumper for plus CO Setting Temporal jumper for Used 24 Vdc out next base or EOL relay out next KIR Series device Detector Base KI IB K

Related Files