Kidde K85001-0663 -- Intelligent CO Detector, Rotary-Addressed

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent CO KIR COD carbon monixide detector brings advanced sensing to a practical design that increases efficiency saves time cuts costs and extends life safety capabilities self diagnostics ensures reliability over the long haul advanced electrochemical CO sensing technology provides benefits that keep occupants safe from carbon mon the killer all KIR Series detectors the KIR COD is an intelligent device gathers analog information from its CO sensor converting this into digital signals To make an alarm decision the detector microprocessor measures and analyzes sensor readings time Digital filters remove signal patterns that are not typical life safety events thus virtually eliminating unwanted alarms KIR COD includes an advanced carbon monoxide sensor the electrochemical cell reaches its end of life after approxi ten years the detector signals a trouble condition to the panel Refer to the control panel documentation for specific of life timing Standard Features Some features described here may not be supported by control systems Check your control panel Installation and Guide for details Next Generation CO Sensing Technology Advanced electrochemical carbon monoxide sensing Markings Provide Easy Testing Identification Uses existing wiring Automatic device mapping Up To 250 Total Addresses Per Loop Non volatile memory Convenient rotary addressing Automatic day night sensitivity adjustment Bicolor green red status LED relay fault isolator and audible mounting bases 1 of 4 A T A S H E E T K85001 0663 to be used for installation purposes Issue 1.1 Catalog Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com and reporting technology microprocessor in each detector provides additional benefits and History Log Automatic Device Mapping and Stable Communication and History Log Each KIR Series detector runs self checks to provide important maintenance infor The results of the self check are automatically updated and stored in the detector non volatile memory Device Mapping The loop controller learns where device serial number address is installed relative to other de on the circuit The mapping feature provides supervision of each installed location to prevent a detector from being reinstalled cleaning etc in a different location from where it was originally Stable Communication On board intelligence means less needs to be sent between the detector and the loop Other than regular supervisory polling response the only needs to communicate with the loop controller when has something new to report mounting bases have wiring terminals that are acces from the after mounting the base to the electrical The bases mount to North American 1 gang boxes and to inch or 4 inch octagon boxes 1 inches 38 mm deep They mount to European BESA and 1 gang boxes with 60.3 mm centers The KI SB4 KI RB4 and KI IB4 mount to North 4 inch sq electrical boxes in addition to the above They include the GSA TS4 Trim Skirt which is used to the ears on the base The KI ABST mounts to a inch square box only tab Indicator Base Base Base Base LED LED GSA LED The remote LED connects to the KI SB KI SB4 Standard Base only It features a North American size plastic faceplate with a white finish and red alarm LED Skirt Supplied with 4 inch bases it can also be ordered to use with the other bases to help hide surface not covered by the smaller bases Bases KIR Series sounder bases are designed for use localized or group alarm signaling is required KI ABDT bases provide sounder capability to the KIR COD when with a FX T3T4 Temporal Pattern Generator to produce the CO TC4 tone pattern KI ABLT bases provide 520 Hz low frequency sounder capabil to the KIR COD when used with a FX T3T4 Temporal Pattern to produce the appropriate CO TC4 tone pattern KI ABLT is suitable for applications requiring low frequency tones detection has rapidly become a standard part of life safety strate everywhere Monitored CO detection is mandated with increas frequency in all types of commercial applications but particularly occupancies such as hotels rooming houses dormitories day facilities schools hospitals assisted living facilities and nursing In fact more than half of the U S population already lives in requiring the installation of CO detectors in some commercial This is because carbon monoxide is the leading cause accidental poisoning deaths in America Known as the CO is odorless tasteless and colorless It claims nearly 500 and results in more than 15,000 hospital visits annually PPM PPM PPM Headache to unconscious dizziness dangerous to life or health of hours 3 hours 2 hours min 2 hours 2 min KIR COD detector is compatible only with the KIR Series Controller Series detectors mount to American 1 gang boxes inch or 4 inch octagon and to 4 inch square elec boxes 1 1 2 inches 38 mm They mount to European and 1 gang boxes with 60.3 fixing centers See mounting installation and wiring for information Maintenance user friendly maintenance program shows the current state each detector and other pertinent messages Single detectors be turned off temporarily from the control panel Availability maintenance features is dependent on the fire alarm system When the CO sensor electrochemical cell reaches its end life the detector signals a Trouble condition to the control panel maintenance regular or selected for proper detector should be planned to meet the requirements of the Au Having Jurisdiction AHJ Refer to current NFPA 72 NFPA and ULC CAN ULC 536 standards Life CO sensor has a 10 year life from the date of manufacture or the control panel indicates a sensor end of life condition comes first The detector signals a TRBL condition on the control panel when the CO sensor reaches end of life Pressing the Details button on the control panel OF LIFE ACT providing verification that it is an end trouble of the CO sensor This trouble remains active until detector is replaced even if the panel is reset 2 of 4 A T A S H E E T K85001 0663 to be used for installation purposes Issue 1.1 Monitior Monitior Sounder Bases Fire plus CO Mode and AB4LT sounder bases configurations require a GSA T3T4 Temporal Pattern Gen to produce the appropriate CO TC4 tone pattern mode for detector of bases VDC listed supply mode wiring detector and system of bases VDC listed supply Wiring detector mounting bases accept 18 AWG 0.75mm2 16 14 AWG 1.5mm2 and 12 AWG 2.5mm wire sizes 16 AWG 1.0mm2 and 18 AWG 0.75mm2 are preferred ease of installation Detector Base KI SB KI SB4 is the basic mounting base Kidde KIR Series detectors GSA LED Remote LED is by this LED resistance wire not exceed Ohms Term Description Not Used DATA IN OUT Not Used DATA IN Remote LED Remote LED Not Used DATA OUT IN IN Signature Controller Previous Device OUT OUT Next Device Detector Base KI IB KI IB4 base includes a built in line fault isolator for use on Class A A detector must be installed for it to operate The isolator does not support the GSA LED Remote LED isolator operates as follows a short on the line causes all iso to open wit

Related Files