Kidde K85001-0665 -- Intelligent Multisensor Smoke, Heat and CO Detector, Rotary-Addressed
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85001-0665-intelligent-multisensor-smoke-heat-and-co-detector-rotary-addressed-8593126074.pdf |
---|---|
Type | |
Size | 1.30 MB |
Downloads |
Text Preview
Intelligent Smoke CO Detector KIR PHCD detector brings advanced multisensing technology a practical design that increases efficiency saves installation cuts costs and extends life safety and property protection Continuous self diagnostics ensures reliability over long haul while environmental compensation helps reduce costs KIR PHCD provides the best of all worlds with comprehensive safety monitoring The combination of optical smoke detection rate of rise heat sensing technology provides efficient iden of smoldering fires as well as fast flaming fires With the element of CO monitoring this detector pulls double duty monitoring the environment for signs of fire as well its invisible yet deadly companion carbon monoxide all KIR Series detectors the KIR PHCD gathers analog from their sensing elements and converts this data into signals To make an alarm decision the detector on board measures and analyzes smoke and heat sensor and compares this information to historical data Digi filters remove signal patterns that are not typical of fires thus eliminating unwanted alarms The detector also analyzes smoke and heat sensors independently from the CO sensor to whether to initiate a fire alarm a life safety CO alarm or Features Some features described here may not be supported by control systems Check your control panel Installation and Guide for details Next Generation Detection Technology optical smoke with rate of rise heat sensing and monoxide detection Wide 0.53 to 3.94 ft 1.7 to 12.35 m smoke obscuration Sensor Markings Provide Easy Testing Identification Uses existing wiring Automatic device mapping Up To 250 Total Addresses Per Loop Two levels of environmental compensation Two levels of dirty detector warning Twenty pre alarm settings Five sensitivity settings Non volatile memory Convenient rotary addressing Environmental compensation Automatic day night sensitivity adjustment Bicolor green red status LED Standard relay fault isolator and audible mounting bases 1 of 4 A T A S H E E T K85001 0665 to be used for installation purposes Issue 1 Catalog Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com detection KIR PHCD detects extremely small particles of combustion triggers an alarm at the first sign of smoke Thanks to its high forward scattering reflective response technology photoelectric smoke sensor responds quickly and reliably to wide range of fire types espe cially slow burning fires fuelled by typically found in modern multi use buildings detection on board rate of rise heat sensor provides a 15 per minute for the detection of fast developing fires The sensor monitors the temperature of the air and determines an alarm should be initiated Detection CO detection such as that provided by the KIR PHCD is mandated with increasing frequency in all types of com applications but particularly in occupancies such as hotels houses dormitories day care facilities schools hospitals living facilities and nursing homes Known as the CO is odorless tasteless and colorless It claims nearly 500 and results in more than 15,000 hospital visits annually Series detectors mount to American 1 gang boxes inch or 4 inch octagon and to 4 inch square elec boxes 1 1 2 inches 38 mm They mount to European and 1 gang boxes with 60.3 fixing centers See mounting installation and wiring for information tab Indicator Maintenance maintenance regular or selected for proper detector should be planned to meet the requirements of the Au Having Jurisdiction AHJ Refer to current NFPA 72 NFPA and ULC CAN ULC 536 standards Sensor Sensitivity KIR PHCD determines when its optical sensor is dirty or and can transmit sensitivity data to the loop controller sensitivity report can also be printed to satisfy NFPA sensitivity which must be conducted at the end of the first and every two years thereafter The availability of maintenance depends on the fire alarm system used Sensor Life CO sensor has a 10 year life from the date of manufacture or the control panel indicates a sensor end of life condition comes first When the sensor reaches its end of life the signals a TRBL ACT condition on the control Pressing the Details button on the control panel displays OF LIFE ACT providing verification that it is an end of life of the CO sensor This trouble remains active until the is replaced even if the panel is reset and reporting technology microprocessor in each detector provides additional benefits and History Log Automatic Device Mapping and Stable Communication and History Log Each KIR Series detector runs self checks to provide important maintenance infor The results of the self check are automatically updated and stored in the detector non volatile memory Device Mapping The loop controller learns where device serial number address is installed relative to other de on the circuit The mapping feature provides supervision of each installed location to prevent a detector from being reinstalled cleaning etc in a different location from where it was originally Stable Communication On board intelligence means less needs to be sent between the detector and the loop Other than regular supervisory polling response the only needs to communicate with the loop controller when has something new to report mounting bases have wiring terminals that are acces from the after mounting the base to the electrical The bases mount to North American 1 gang boxes and to inch or 4 inch octagon boxes 1 inches 38 mm deep They mount to European BESA and 1 gang boxes with 60.3 mm centers The KI SB4 KI RB4 and KI IB4 mount to North 4 inch sq electrical boxes in addition to the above They include the GSA TS4 Trim Skirt which is used to the ears on the base The KI ABST mounts to a inch square box only Base Base Base Base LED LED GSA LED The remote LED connects to the KI SB KI SB4 Standard Base only It features a North American size plastic faceplate with a white finish and red alarm LED Trim Skirt Supplied with 4 inch bases it can also ordered separately to use with the other bases to help hide imperfections not covered by the smaller bases Bases KIR Series sounder bases are designed for use localized or group alarm signaling is required KI ABDT bases provide sounder capability to the KIR PHCD used with a FX T3T4 Temporal Pattern Generator to sepa CO TC4 and Fire TC3 tone patterns KI ABLT bases provide 520 Hz low frequency sounder capability the KIR PHCD when used with a FX T3T4 Temporal Pattern to separate CO TC4 and Fire TC3 tone patterns KI ABLT is suitable for applications requiring low frequency tones 2 of 4 A T A S H E E T K85001 0665 to be used for installation purposes Issue 1 Wiring detector mounting bases accept 18 AWG 0.75mm2 16 14 AWG 1.5mm2 and 12 AWG 2.5mm wire sizes 16 AWG 1.0mm2 and 18 AWG 0.75mm2 are preferred ease of installation Detector Base KI SB KI SB4 is the basic mounting base Kidde KIR Series detectors GSA LED Remote LED is by this LED resistance wire not exceed Ohms Sounder Bases Fire Mode AB4G AB4G LF sounder bases Setting High for dB cuts DATA DATA Term Description 1 Not Used 2 DATA IN OUT 3 Not Used 4 DATA IN 4 Remote LED 5 Remote LED 6 Not Used 7 DATA OUT IN IN Signature Controller Previous Device OUT OUT Next Device Vdc in power supply previous base in KIR Device Control o