Kidde K85001-1020 -- Kidde Intelligent Optica Rotary Smoke Detector

File Preview
File Preview
Click below to download for free

Text Preview

Intelligent Smoke Kidde Intelligent Optica Series KIR OSD smoke detector advanced optical photoelectric sensing technology to a design that increases efficiency saves installation time costs and extends life safety and property protection Continuous self diagnostics ensure reliability over long haul while environmental compensation helps reduce costs all Kidde Intelligent Optica Series detectors the KIR OSD is intelligent device that gathers analog information from multiple sensors converting this data into digital signals Utilizing optical wavelengths combined with multiple detection angles KIR OSD differentiates particles that are not representative actual smoke Particle data is input into digital filters which a series of ratios removing signal patterns that are typical of sources thus reducing unwanted alarms To make an decision the detector on board microprocessor measures analyzes all optical sensor readings and compares this to preprogrammed settings 1 of 4 Reduce Cooking Alarms 268 7th Ed Features Patented multi criteria optical smoke sensing technology Wide 0.5 to 4.36 ft 1.6 to 13.6 m smoke obscuration Uses Existing Wiring Integrated nuisance rejection reducing unwanted alarms general cooking particulates Listed to UL 268 7th edition Up To 250 detector and module Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre Alarm Settings Five Sensitivity Settings Non Volatile Memory Rotary Addressing 1 125 Automatic Day Night Sensitivity Adjustment Bicolor Green Red Status LED Standard Relay Fault Isolator and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Some features described here may not be supported by control systems Check your control panel Installation and Guide for details D A T A S H E E T K85001 1020 to be used for installation purposes Issue 1 Catalog u Intelligent Initiating DevicesTechnology that saves livesROTARY ADDRESSINGfirealarmresources com KIR OSD detects particles from a wide range of combustion and will trigger an alarm when smoke density in the reaches preprogrammed level Thanks to its high patented reflective response technology the smoke responds quickly and reliably to a wide range of fire types both fast and slow burning fires fueled by combustibles found in modern multi use buildings KIR OSD detector is compatible only with control panels a Kidde Intelligent Loop controller mounting bases have wiring terminals that are from the after mounting the base to the box The bases mount to North American 1 gang boxes to 3 inch or 4 inch octagon boxes 1 inches 38 mm They also mount to European BESA and 1 gang boxes with mm fixing centers The KI SB4 KI RB4 and KI IB4 mount to American 4 inch sq electrical boxes in addition to the above They include the KI TS4 Trim Skirt which is used to cover ears on the base The KI ABST mounts to a 4 inch box only Intelligent Series detector mount to North American boxes 3 1 2 inch or inch octagon boxes and to inch square electrical boxes inches 38 mm deep mount to European BESA 1 gang boxes with 60.3 mm centers See mounting base and wiring for information tab Indicator and reporting technology microprocessor in each detector provides additional Self diagnostics and History Log Multi criteria and Fast Stable Communication and History Log Each Kidde Intelligent detector constantly runs self checks to provide important information The results of the self check are updated and permanently stored in the detector memory Criteria Detection Each detector houses an advanced chamber providing optical recognition of particles the onboard microprocessor to distinguish between particles and nuisance sources like cooking and steam Stable Communication On board intelligence means information needs to be sent between the detector and the controller Other than regular supervisory polling response detector only needs to communicate with the loop controller it has something new to report Maintenance detector automatically identifies when it is dirty or defective causes a detector message The detector sensitivity can also be transmitted to the loop controller sensitivity report may be printed to satisfy NFPA sensitivity which must be conducted at the end of the first and every two years thereafter user friendly maintenance program shows the current state each detector and other pertinent messages Single detectors be turned off temporarily from the control panel Availability of features is dependent on the fire alarm system used 2 of 4 Base Base Base Base LED LED GSA LED The remote LED connects to the KI SB KI SB4 Standard Base only It features a North American size plastic faceplate with a white finish and red alarm LED Skirt Supplied with 4 inch bases it can also be ordered to use with the other bases to help hide surface not covered by the smaller bases Bases Kidde Intelligent Series sounder bases designed for use where localized or group alarm signaling required KI ABST bases provide sounder capability to Kidde Intelligent to heat and smoke detectors They are not intended use with combination carbon monoxide detectors in mode KI ABDT bases provide sounder capability to Kidde Series smoke and heat detectors as well as carbon detectors when used with a FX T3T4 Temporal Generator KI ABLT bases provide 520 Hz low frequency capability to Kidde Intelligent Series smoke and heat as well as carbon monoxide detectors when with a FX T3T4 Temporal Pattern Generator The is suitable for applications requiring low audible tones Addressing is made easy through the rotary dials located on the of the detector head Use a screwdriver to adjust the TENS switch 0 through 12 to set the 10s digit and the ONES switch to set the digit 0 through 9 The control panel will any duplicate addresses 5 9 screwdriver here device address 21 set TENS rotary switch to 2 set the ONES rotary switch to 1 D A T A S H E E T K85001 1020 to be used for installation purposes Issue 1 Sounder Bases Fire Mode ABDT ABLT sounder bases Setting High for dB cuts SIG OUT DATA DATA Mode Fire jumper Fire plus CO Setting Temporal jumper Steady Vdc in power supply previous base in Kidde Controller or device 24 Vdc out next base or EOL relay out next Kidde device Cautions This detector does not operate without electrical power fires frequently cause power interruption discuss safeguards with the local fire protection specialist This detector does not sense fires in areas where smoke reach the detector Smoke from fires in walls or on the opposite side of closed doors may not the detector In Canada install according to CAN ULC S524 Standard for Installation of Fire Alarm Systems CSA C22.1 Canadian Code and the local authority having jurisdiction Wiring detector mounting bases accept 18 AWG 0.75mm2 16 14 AWG 1.5mm2 and 12 AWG 2.5mm wire sizes 16 AWG 1.0mm2 and 18 AWG 0.75mm2 are preferred ease of installation Detector Base KI SB KI SB4 is the basic mounting for KIDDE Intelligent Series The GSA LED LED is supported by Base LED resistance wire not exceed Ohms Term Description 1 Not Used 2 DATA IN OUT 3 Not Used 4 DAT

Related Files