Kidde K85001-1021 -- Genesis LED EGC Series Ceiling Mount Notification Devices
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kidde-k85001-1021-genesis-led-egc-series-ceiling-mount-notification-devices-2159847036.pdf |
---|---|
Type | |
Size | 2.27 MB |
Downloads |
Text Preview
Genesis LED Series Mount Devices LED EGC Series horns and LED strobes feature a sleek profile design and energy efficient technology that makes less expensive to install and operate by reducing overhead performance LEDs require fewer power supplies backup and batteries These new appliances are designed with and life safety in mind LED EGC Series uses high efficiency optics combined patented electronics to deliver a highly controlled and focused light distribution pattern in exchange for current requirements Strobes feature field selectable 30,75 or 115 cd light output with Xenon type strobes Genesis LED EGC Series need fewer power supplies and often smaller wire which lightens conduit requirements They are also compatible with legacy strobes so there no need to all your existing devices to upgrade to new LED technology fact EGC strobes can be mixed on the same circuit and used in same field of view as Xenon based strobes This makes Genesis EGC Series ideal for new installations and retrofits alike sound output levels provide the flexibility life safety projects demand while the Genesis LED protocol keeps multiple strobes on compatible NAC synchronized to well within NFPA 72 requirements is another area where EGC Series appliances shine universal room side wiring plate allows for pre installation electrical wiring as well as checking continuity with the diagnostics check bar EGC Series devices can then be snapped into place with the confidence of knowing the is correct The innovative under cover diagnostic test points easy access to device circuit testing while mounted Features High Performance LED Strobe Technology More devices per circuit Ability to use lower gauge wire Longer wire runs Fewer booster power supplies Ultra low device current consumption allows High efficiency optics Selectable 15 30 75 or 115 cd light output LED devices may be mixed with legacy Xenon strobes Efficient Audible Output Selectable high or low dB horn output Selectable temporal or steady horn output Improved audio frequency range for better wall penetration Low profile Design Ultra slim protrudes about 1.5 from the mounting surface Attractive appearance no visible mounting screws Multiple Marking Options Order Red or White with or without FIRE markings Change markings at any time with replaceable covers Easy to Install diagnostics check bar Pre install and pre wire with convenient universal room side wiring plate Check electrical continuity on room side wiring plate with Diagnostics port streamlines device circuit testing Fits 1 gang 2 gang 4 inch octagon and 4 inch square electrical boxes Optional red and white trim plates available Slide switches for field configuration 12 to 18 AWG in out screw terminals for quick wiring 1 of 6 D A T A S H E E T K85001 1021 to be used for installation purposes Issue 1.1 Catalog u Strobes Horns Bells ChimesTechnology that saves livesfirealarmresources com LED EGC Series horns strobes and horn strobes mount any standard one gang two gang 4 inch octagon and 4 inch electrical box Matching optional EGCT trim rings are to cover oversized openings Optional color matched surface boxes are also available Genesis LED EGC are listed to be both wall mounted or ceiling mounted EGC Series strobes are UL 1971 listed for use indoors ceiling mounted public mode notification appliances for the impaired Prevailing codes require strobes to be used ambient noise conditions exceed 105 dBA 87 dBA in where occupants use hearing protection and in of public accommodation as defined in the Americans Disabilities Act is important in order to avoid triggering seizures people with photosensitive epilepsy All Genesis strobes exceed synchronization requirements within 10 milliseconds over a period when used with a synchronization source the specifications table for a list of compatible sources horn output reaches as high as 92 dBA and features an audio frequency range compared with other Genesis This results in excellent sound penetration through walls and clear warning of danger Horn only models may be configured for coded or non coded notification appliance circuits They can be set for high or low dBA output This setting reduces horn by about 6 dBA suggested sound pressure level for each signaling zone used alarm signals is at least 15 dBA above the average ambient level or 5 dBA above the maximum sound level having a of at least 60 seconds whichever is greater These values measured at five feet 1.5 m above the floor The average sound level is A weighted fast response sound pressure over a 24 hour period the distance from the signal to the ear will theoretically in a 6 dBA reduction of the received sound pressure level actual effect depends on the acoustic environment in the space 3 dBA difference represents a barely noticeable change in volume EGC horns and strobes mount to the required GP10 side wiring plate The GP10 mounting plate is included with device for convenient pre installing and pre wiring The device be removed easily from the room side wiring plate by pushing with a screwdriver The cover can also be removed from the easily with a screwdriver to access the light and sound settings and a diagnostics test port for voltage testing Cover Device in polarity in the condition Electrical Box Trim Plate optional Wiring plate required included with device Machine screw 2X supplied with wiring plate EGC signaling appliance out Clip 2 of 6 D A T A S H E E T K85001 1021 to be used for installation purposes Issue 1.1 Notification Appliances cm cm Trim Plate optional cm cm Configuration horn and horn strobe models are factory set to sound in three pulse temporal pattern By sliding the tone selector switch only models may be configured for constant horn output that be coded at precise intervals by KIDDE control panels and modules Temporal 3 coding is the required output for fire notification per NFPA 72 Any device coding other than temporal is at the discretion and approval of the local authority having AHJ and horn strobes are factory set for high dB output Low output may be selected by sliding the tone selector switch reduces the output by about 6 dBA LED clear strobes and horn strobes may be set for 15 75 or 115 candela output The output setting is changed by removing the cover and sliding the candela switch to the setting The device does not have to be removed from wall to change the output setting The setting remains visible a small window on the device after the cover is closed and Sound Output Settings 30 115 to 33 to 33 mA mA Constant low dB Constant high dB T3 temporal low dB T3 temporal high dB 115 candela 75 candela 30 candela 15 candela to 33 current mA mA mA mA to 33 30 115 points indicated are used to validate Notification Appliance and verify device function 3 of 6 setting T Low T High to 33 VDC to 33 VFWR mA mA mA mA D A T A S H E E T K85001 1021 to be used for installation purposes Issue 1.1 Output Horn Strobe setting T Low T High dBA dBA S525 dBA dBA pattern Horn Models ULC and 55 and 50 dBA pattern Horn Strobe Models ULC