Kidde K85005-0125 -- Remote Booster Power Supplies

File Preview
File Preview
Click below to download for free

File Data

Name kidde-k85005-0125-remote-booster-power-supplies-6975403812.pdf
Type PDF
Size 962.71 KB
Downloads

Text Preview

Remote Booster Supplies MIRBPS10A Booster Power Supply MIRBPS is a UL 864 10th Edition power supply It is a 24 Vdc filtered regulated and su unit that can easily be configured to provide additional appliance circuits NACs or auxiliary power for Mass Communication MNEC as well as life applications MIRBPS contains the circuitry to monitor and charge internal external batteries Its steel enclosure has room for up to two ampere hour batteries The MIRBPS has four Class B convert to two Class A NACs These can be activated in one or two from the MIRBPS unique dual input circuits MIRBPS is available in 6.5 or 10 ampere models Each output has a capacity of three amperes total current draw cannot the unit rating MIRBPS meets current UL requirements and is listed under following standards CCN 10th ed ition UOXX Fire Alarm Systems ANET UEHX7 AOTX AOTX7 APAW APAW7 APOU APOU7 Proprietary Burglar Alarm System Units AMCX UOXXC AOTX7 No 205 Station Alarm Unit Units Fire Alarm Canada Burglar Alarm Units and Systems Canada Equipment Canada Alarm Units and Systems Burglar Alarm Units and Systems Station Connected Burglar Alarm Units and Systems Features Allows for reliable filtered and regulated power to be installed needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap synchronization Supports coded output operation Self restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently On board diagnostic LEDs identify wiring or internal faults Standard Kidde keyed lockable steel cabinet with removable field configuration and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening OSHPD seismic pre approval component Importance Factor 1.5 1 of 4 D A T A S H E E T K85005 0125 to be used for installation purposes Issue 1.2 Catalog u Power Supplies and AccessoriesTechnology that saves livesfirealarmresources com View View knockouts 3 4 in conduit cm in cm in cm in cm in cm in cm in cm routing MIRBPS provides additional power and circuits for notification and other 24 Vdc loads It is listed for indoor dry loca and can easily be installed where needed conditions are indicated on the on board diagnostic LEDs the MIRBPS input sense circuit and the trouble relay if While this provides indication to the host system MIRBPS can still be activated upon command A separate AC contact is available on the MIRBPS circuit board which can programmed for trouble or AC Fail There are seven on board LEDs one for each NAC fault one for battery fault one ground fault and one for AC power unique dual input activation circuits of the MIRBPS can be by any voltage from 6 to 45 VDC filtered regulated or to 33 Vdc full wave rectified unfiltered The first input circuit be configured to activate 1 4 of the four possible outputs The input circuit can be configured to control circuits 3 and 4 outputs are configured for auxiliary operation these circuits be configured to stay on or automatically deactivate 30 sec after AC power is lost This feature makes these circuits ideal door holder applications The MIRBPS also has a separate 200 24 Vdc output that can be used to power internal activation NACs can be configured for a 3 3 3 temporal or continu output This makes the MIRBPS ideal for applications requir signaling rates that are not available from the main system addition to the internally generated signal rates the MIRBPS also be configured to follow the coded signal rate of the main NACs This allows for the seamless expansion of existing MIRBPS enclosure has mounting brackets for up to three modules to the right of the circuit board Specification where needed Kidde MIRBPS Series Booster Power Sup MIRBPS that are interconnected to and supervised by the system The MIRBPS shall function as a stand alone auxiliary supply with its own fully supervised battery compliment MIRBPS battery compliment shall be sized to match the of the main system The MIRBPS shall be capable supervising and charging batteries having the capacity of 24 for Mass Notification Emergency Communication and life safety applications MIRBPS shall be capable of installation for a seismic com Importance Factor of 1.5 The MIRBPS shall provide minimum of four independent fully supervised Class B circuits can be field configurable for notification appliance circuits or 24 Vdc power circuits MIRBPS NACs shall be convertible a minimum of two Class A NACs Each MIRBPS output circuit be rated at 3 amperes at 24 Vdc Each output circuit shall provided with automatically restoring overcurrent protection MIRBPS shall be operable from the main system NAC and or Signature Series control modules MIRBPS NACs shall be for continuous or 3 3 3 temporal rate Fault condi on the MIRBPS shall not impede operation of main system The MIRBPS shall be provided with ground fault detection and a separate AC fail relay Maintain 1 4 inch 6 mm spacing between power limited and nonpower limited or use type FPL FPLR or FPLP cable per NEC Power limited and supervised when not configured as auxiliary power Non when configured as auxiliary power Source must be power limited Source determines supervision When using larger batteries make sure to position the battery terminals towards door 2 of 4 D A T A S H E E T K85005 0125 to be used for installation purposes Issue 1.2 Wiring or cascaded booster on a notification appliance circuit Circuit Circuit NAC end of line resistors are not required to be at the booster terminals This allows multiple to be driven from a single NAC circuit without the for special configurations Alarm Panel next signaling booster or resistor output 1 output 2 output 3 output 4 Power the Booster for Power Fail delay operation CC1 S modules using the sense inputs appliance circuit NAC appliance circuit NAC appliance circuit NAC appliance circuit NAC listed 15 KW listed 15 KW mA AUX 1 2 47 k listed 15 k listed 15 k module 1 3 mA AUX 1 2 4 in from device Signature out to device in from previous or Signature out to device Booster supports AC Power fail delay three hours via its trouble contact when switch SW2 6 is on All other troubles reported to supervising module or panel delay via Sense inputs 47 K 47 K module module 3 of 4 D A T A S H E E T K85005 0125 to be used for installation purposes Issue 1.2 that saves lives us 888.244.9979 Option 4 kidde esfire com kidde fire carrier com is a Carrier brand Town Center Pkwy FL 34202 2021 Carrier rights reserved Line Voltage Appliance Ratings Relay Outputs Current an existing NAC Interna

Related Files