Kingfisher 75406
File Preview
Click below to download for free
Click below to download for free
File Data
Name | kingfisher-75406-2091473856.pdf |
---|---|
Type | |
Size | 807.13 KB |
Downloads |
Text Preview
RADIO RECEIVER MANUAL Company Foster Avenue Wheeling IL 60090 6574 847 f 847 e mail sales kfco com RECEIVER CONTOLLER Radio Receiver Controller is a microprocessor based device which can be remotely activated by Radio Transmitters to automatically control a fire pump controller remote sirens lights or other electri devices The Radio Receiver Controller basically consists of the following modules antenna receives transmissions from the transmitters located in the remote area radio receiver inputs RF from the antenna to its RF module It is amplified and demodulated audio signal is extracted and prepared for the tone filter tone filter inputs the audio signal and filters out the individual tones and encodes them for by the microprocessor microprocessor monitors validates and deciphers the encoded tone information It compares newly acquired information with the critical transmitter and zone information which has been and loaded in the memory If a match is found it is ready to propagate the control to the output relays relay module consists of four form C relays which provide maximum contact current rated at 7 240VAC or 30VDC Relays 1 2 and 3 can be programmed individually to react to a certain of critical transmitters and zones The On time delay 0 250seconds and the Off time delay 1 can be programmed into the software Relay 4 gives a system supervisory output power supply provides the necessary power requirements for all the circuitry of the Radio Controller and provides a charging current to the back up battery case of an AC power failure the back up battery supplies the necessary power and is recharged the power supply module Company Foster Ave Wheeling IL 60090 6574 847 f 847 e mail service kfco com Internet www kfco com 75406 04 05 RISK OF ELECTRICAL SHOCK READ THIS INSTALLATION MANUAL COMPLETELY BEFORE OR SERVICING PANELS CHASSIS MUST BE CONNECTED TO EARTH GROUND OBSERVE HOT AND NEUTRAL POLARITY WHEN CONNECTING AC DO NOT APPLY AC OR BATTERY POWER DURING INSTALLATION AVOID INSTALLATIONS THAT ARE IN DIRECT SUNLIGHT AND IN RUNOFF PATHS SELECTION LOCATE AND INSTALL THE PANEL SO THAT VIBRATION OR JARRING NOT CAUSE ACCIDENTAL OPERATION MOUNT PANEL ON A STRUCTURALLY SOUND WALL GENERALLY LOCATION IS A WALL AREA CONVENIENT TO RUN THE CON FOR CONTROL CIRCUITS ANTENNA AND AC POWER THE PANEL SHOULD BE LOCATED TO PROVIDE A CLEAR VIEW OF AND MINIMUM ARC OF 16 FOR PANEL DOOR CLEAR OPERATION OF SWITCHES AND MAINTENANCE OPERATIONS 75406 04 05 Company Foster Ave Wheeling IL 60090 6574 847 f 847 e mail service kfco com Internet www kfco com of Contents of Enclosure 1 1 Mounting 1 Wiring 2 Receiver Controller 3 Description 4 5 Box Number Description of Operation 5 Transmitter Numbers 6 10 11 Parts 12 Company Foster Ave Wheeling IL 60090 6574 847 f 847 e mail service kfco com Internet www kfco com 75406 04 05 OF ENCLOSURE shall be undertaken only by properly skilled trained and qualified professionals who are experienced modern industrial installations and all applicable codes and requirements Read all instructions first Do not connect batteries or apply power until wiring and installation is complete and checked King Fisher Co equipment shall be installed in accordance with applicable NFPA codes the National Fire Codes the National Electric Code the Local Authority Having Jurisdiction and King Fisher Co man and drawings Locate a suitable position and structure for mount the enclosure MOUNTING REMOVE the 2 subplate assemblies from the by removing the eight nuts and wash located at each corner of the subplates Place a temporary protected location REMOVE the mounting hole knockouts located the rear of the enclosure RUN all conduit necessary to the Conduit should not be to the top surface of the as moisture from conden or water may drip or leak on internal electronic componentents are provided on the bot of the enclosure DO NOT knockouts with subplates Attach conduit to enclosure waterproof fittings with star DO NOT use reducing Separate conduit runs are for Power wiring MOUNT HARDWARE S S Screw S S Flat Washer Mounting Hole side view Anchor side view Mtdg Detail Company Foster Ave Wheeling IL 60090 6574 847 f 847 e mail service kfco com Internet www kfco com 75406 04 05 1 WIRING wiring shall be based on current NFPA National Fire Protection Association and NEC Electrical Code standards Due to varying local and or other building electric and fire it is highly recommended that the installer review all applicable codes in addition to NFC Fire Codes Approval and final acceptance of system installation shall be subject to the having jurisdiction Dress field wiring around the perimeter of the enclosure 120 VAC main power should be dressed the lower right hand corner of the enclosure Carefully re install the subplate assemblies in the enclo using the eight nuts AC wiring The Radio Receiver Controller panel operates on 120 VAC 50 60 Hz single phase Connect Hot H and Neutral N as shown to the terminal block in the lower right hand of the subplate This panel requires a 15 Amp 120 VAC circuit breaker or fused circuit to installed external to the panel Connect Earth Ground to the ground lug provided at the bottom the subplate The circuitry within the Radio Receiver Controller contains electronic filters and protecors to aid in suppressing spikes noise and lightning strikes and requires ground con to function 2 75406 04 05 Company Foster Ave Wheeling IL 60090 6574 847 f 847 e mail service kfco com Internet www kfco com NOT APPLY POWER TO PANEL Filter Board Supply Board Interface Button Connector Disk Supply Lug Power Input Connector Company Foster Ave Wheeling IL 60090 6574 847 f 847 e mail service kfco com Internet www kfco com 75406 04 05 3 ALARM FORMAT ALARM SITES ERROR CHECKING Radio Receiver Controller is a microprocessor based device which can be remotely activated by Radio Transmitters to automatically control a fire pump controller remote sirens lights or other electri devices standard Tone format TO 999,999 different Remote Alarm Site codes with 9,999 codes Site received signals are checked for proper format alarm site match errors Highly resistant to false alarm incidence due to noise stat storm activity or multiple simultaneous transmissions CONSTRUCTION solid state construction using modular plug in cards designed fast service and maintenance TEMPERATURE to 49 deg C Operational 20 to 50 deg C Storage DIMENSIONS 16 inches x 42 inches x 6.125 inches Other configurations are available Weight 26 lbs antenna system should be arranged to provide good reception from all remote sites RF line of site possible The Radio Receiver Controller is designed for a 50 ohm antenna and 50 ohm coaxial The Radio Receiver Controller antenna an