Mircom CAT-5101 MS-400 Series Manual Stations (English)

File Preview
File Preview
Click below to download for free

File Data

Name mircom-cat-5101-ms-400-series-manual-stations-english-5730248916.pdf
Type PDF
Size 732.57 KB
Downloads

Text Preview

METAL FIRE ALARM STATION SERIES Extruded Aluminium Construction Low Pro le Design Single Gang Mount to Double Action Rod Optional one provided manual stations can be easily converted from a single to a double action station with the addition of the double action lever on the station handle will release the internal to trigger the alarm detection circuit MS 402 MS 406 and MS 408 two stage versions provide a key switch which is accessible after the has been pulled Operation of the key switch connected to a separate general alarm circuit initiate the 2nd stage of a two stage alarm signalling cations manual station shall be Mircom MS 400 Series instructions shall be in raised English and lettering and the unit shall be constructed of aluminium and nished in red enamel paint provide quick identi cation Pulling the handle shall immediate operation of the alarm detection In addition those stations installed in a two stage shall come equipped with an internal key switch to operate the 2nd stage alarm initiating circuit manual re alarm stations shall be installed as per speci c requirements outlined in the ULC codes as as all other applicable national or local codes and durable Mircom MS 400 Series Stations provide manual re reporting The Series manual stations are non coded single double action devices which initiate an alarm when Resetting is accomplished by inserting a 1 8 from the front The handle once pulled remain open and cannot be reset without utilizing screwdriver MS 400 Series manual stations are constructed durable aluminium and nished in red enamel paint abrasion resistant label with large raised letters clear legible instructions MS 400 Series Manual Stations are available in different con gurations The MS 401 is a single single stage manual station The MS 402 two is similar to the MS 401 single stage except it an additional General Alarm G A N O switch safety reasons the G A switch is only accessible the handle has been pulled A special key is with each unit Models MS 405 and MS 407 both single stage manual stations The MS 405 an additional N O switch while the MS 407 has additional N C switch Models MS 406 and MS are both two stage manual stations The MS 406 an additional N O switch while the MS 408 has an N C switch reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER SURFACE BACKBOX DOUBLE ACTION KIT MS DA BREAK GLASS ROD Diagrams PREVIOUS STATION PREVIOUS STATION MS 402 MS 408 MS 407 NEXT STATION OR OF LINE DEVICE NEXT STATION OR OF LINE DEVICE MS 406 ONLY PREVIOUS STATION FUNCTION NOTE 2 NEXT STATION OR OF LINE DEVICE FUNCTION MS 408 NOTE 2 KEYSWITCH MS 406 MS 408 ONLY SWITCH MODELS WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTIONS IS MAINTAINED N O SWITCH FOR MODEL MS 406 N C SWITCH FOR MODEL MS 408 MOUNT STATION TO 2 X 4 X 2 1 4 OUTLET BOX SWITCH RATING ALL MODELS 1A 30 VDC Information SWITCH WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTION IS MAINTAINED N O SWITCH FOR MODEL MS 405 N C SWITCH FOR MODEL MS 407 MOUNT STATION TO 2 X 4 X 2 1 4 OUTLET BOX SWITCH RATING ALL MODELS 1A 30 VDC Stage Manual Station Stage Manual Station Stage Manual Station with additional N O Switch Stage Manual Station with additional N O Switch Stage Manual Station with additional N C Switch Stage Manual Station with additional N C Switch Action Lever Kit converts any of the above to double action stations TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 5101 7

Related Files