Mircom CAT-5102 MS-400U Series Manual Stations (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5102-ms-400u-series-manual-stations-english-6205834917.pdf |
---|---|
Type | |
Size | 766.49 KB |
Downloads |
Text Preview
METAL FIRE ALARM STATION SERIES Extruded Aluminium Construction Low Pro le Design Single Gang Mount to Double Action Rod Optional one provided on the station handle will release the internal to trigger the alarm detection circuit MS 402U MS 406U and MS 408U two stage also provide a key switch which is accessible the handle has been pulled Operation of the key when connected to a separate general alarm will initiate the 2nd stage of a two stage alarm system cations single action manual station shall be Mircom MS Series Operating instructions shall be in raised lettering and the unit shall be constructed of aluminium nished in red enamel paint to quick identi cation Pulling the handle shall immediate operation of the alarm detection In addition those stations installed in a two stage shall come equipped with an internal key switch to operate the 2nd stage alarm initiating circuit manual re alarm stations shall be installed as per speci c requirements outlined in the UL codes as as all other applicable national or local codes and durable Mircom MS 400U Series of stations provide manual re reporting The 400U Series manual stations are non coded single double action devices which initiate an alarm when Resetting is accomplished by inserting a 1 8 from the front The handle once pulled remain open and cannot be reset without utilizing screwdriver MS 400U Series manual stations are constructed durable aluminium and nished in red An abrasion label with large raised letters provides clear instructions model MS 402U two stage is similar to the MS single stage except it contains an additional Alarm G A N O switch For safety reasons G A switch is only accessible after the handle has pulled A special key is supplied with each unit model MS 405U is similar to the MS 401U except has an additional N O switch The model MS 406U is to the MS 402U except it has an additional N O The model MS 407U is similar to the MS 401U it has an additional N C switch The model is similar to the MS 402U except it has an N C switch All manual stations can be easily from single action to double action station by addition of the MS DA double action lever reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES 313 97 E NUMBER SURFACE BACKBOX DOUBLE ACTION KIT MS DA BREAK GLASS ROD MS 407U Diagrams PREVIOUS STATION PREVIOUS STATION MS 402U MS 408U FUNCTION MS 408 NOTE 2 KEYSWITCH MS 406 MS 408 ONLY SWITCH MODELS WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTIONS IS MAINTAINED N O SWITCH FOR MODEL MS 406 N C SWITCH FOR MODEL MS 408 MOUNT STATION TO 2 X 4 X 2 1 4 OUTLET BOX SWITCH RATING ALL MODELS 1A 30 VDC Information NEXT STATION OR OF LINE DEVICE NEXT STATION OR OF LINE DEVICE MS 406 ONLY PREVIOUS STATION FUNCTION NOTE 2 NEXT STATION OR OF LINE DEVICE SWITCH WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTION IS MAINTAINED N O SWITCH FOR MODEL MS 405 N C SWITCH FOR MODEL MS 407 MOUNT STATION TO 2 X 4 X 2 1 4 OUTLET BOX SWITCH RATING ALL MODELS 1A 30 VDC Stage Manual Station Stage Manual Station Stage Manual Station with additional N O Switch Stage Manual Station with additional N O Switch Stage Manual Station with additional N C Switch Stage Manual Station with additional N C Switch Action Lever Kit converts any of the above to double action stations TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5102 6