Mircom CAT-5128 i3 Series Photoelectric Smoke Detectors (English)

File Preview
File Preview
Click below to download for free

Text Preview

PHOTOELECTRIC SMOKE DETECTORS SERIES detector line mounting base included wire entry port terminals with SEMS screws to octagonal and single gang 4 square backboxes or direct to ceiling Lock attachment to base cover and chamber for easy cleaning remote maintenance signaling compensation and smoothing algorithms ed sensitivity measurement angle dual color LED indication testing via EZ Walk feature test switch Speci cations detector shall be an i3 Series model listed to Laboratories UL 268 for Fire Protection Systems The detector shall be a photoelectric model 2W B 4W B or a combination photoelectric model 2WT B 4WT B with thermal sensor rated 135 57.2 The detector shall include a mounting for mounting to 3 and 4 inch octagonal single and 4 inch square back boxes with a plaster ring or mount to the ceiling using drywall anchors Wiring shall be made by means of SEMS screws detector shall allow pre wiring of the base and the shall be a plug in type The detector shall have a sensitivity of 2.5 per foot nominal as measured the UL smoke box The detector shall be capable of adjusting its sensitivity by means of drift and smoothing algorithms The detector provide dual color LED indication which blinks to power up normal standby out of sensitivity alarm freeze trouble model 2WT B 4WT B conditions used in conjunction with the 2W MOD2 module 2 models shall include a maintenance signal to indicate need for maintenance at the alarm control panel and provide a loop testing capability to verify the circuit testing each detector individually Feature MOUNT i3 series smoke detectors represent a signi cant in conventional detection The i3 family is on three principles Installation Ease Intelligence Instant Inspection Ease i3 line rede nes installation ease with its plug in design allows an installer to pre wire the bases included with heads The large wire entry port and in line terminals ample room for neatly routing the wiring inside base The base accommodates a variety of back box methods as well as direct mounting with drywall To complete the installation i3 heads plug in to base with a simple Stop Drop Lock action detectors offer a number of intelligent features to testing and maintenance Drift compensation smoothing algorithms are standard with the i3 line minimize nuisance alarms When connected to the loop test maintenance module or a panel with the i3 protocol 2 wire i3 detectors are of generating a remote maintenance signal when are in need of cleaning This signal is indicated via LED located at the module and the panel To read the of i3 detectors the SENS RDR is a wireless that displays the sensitivity in terms of percent per obscuration Inspection i3 series provides wide angle red and green LED for instant inspection of the detector condition normal standby out of sensitivity alarm or trouble conditions When connected to the 2W loop test maintenance module or a panel with i3 protocol the EZ Walk loop test feature is available 2 wire i3 detectors This feature veri es the initiating wiring by providing LED status indication at each OFF TAB TAMPER LOCK TAB NUMBER reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES Diagrams and 2WT B Wiring Diagram and 4WT B Wiring Diagram OR OR OR OR OR Speci cations Voltage 12 24 V non polarized 8.5 V 35 V Ripple Voltage of nominal peak to peak Modes Mode up standby of sensitivity trouble Speci cations Temperature Range and 4W B 0 and 4WT B 0 Humidity Range to 95 RH non condensing Sensor 57.2 xed Trouble and 4WT B only 41 5 Current 50 maximum average 50 maximum average Alarm Current 130 mA limited by control panel 20 mA 12V 23mA 24V Standby Current 100 n a Contact Ratings n a 0.5 A 30V AC DC Up Sequence for LED Indication LED status indication seconds LED every 10 secs every 5 secs LED every 10 secs every 5 secs every 10 secs nominal Terminals AWG including base inches 127 mm diameter inches 51 mm height oz 178 grams 3 octagonal back box 4 inch octagonal back box Single gang back box 4 inch square back box with a plaster ring Direct mount to ceiling Information Number Wiring Current Series 2 wire loop test maintenance module Series Sensitivity Reader Series Retro t Adapter Bracket Series Removal Replacement Tool mA max limited by control panel mA max limited by control panel mA 12V 23mA 24V mA 12V 23mA 24V TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5128 4

Related Files