Mircom CAT-5129 i3 Series 2-wire Loop Test Maintenance Module (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5129-i3-series-2-wire-loop-test-maintenance-module-english-2349687015.pdf |
---|---|
Type | |
Size | 799.96 KB |
Downloads |
Text Preview
2 WIRE LOOP TEST MAINTENANCE MODULE SERIES all 2 wire i3 detectors to be used on compatible 2 or 4 wire re alarm control the i3 remote maintenance signal visual indication and an output relay a detector on the loop requires cleaning the EZ Walk loop test Style D wiring on IDC loops red and yellow LEDs indicate Loop communication status Maintenance alert Freeze trouble Alarm EZ Walk test enabled Wiring fault to 4 back box terminal blocks with SEMS screws Speci cations test maintenance module shall be an i3 series number 2W MOD2 listed to Underwriters UL 864 for Control Units for Fire Signaling Systems The module shall provisions for mounting to 4 inch square boxes Wiring connections shall be made by of SEMS screws The module shall provide LED indicators which will blink or illuminate to communication status maintenance alert or freeze trouble conditions and EZ Walk loop mode The module shall allow communication to i3 detectors with any UL listed re alarm control The 2W MOD2 shall offer provisions for Style D on IDC loops and shall provide a loop testing to verify the initiating loop wiring 2W MOD2 two wire loop test maintenance module the benefits of the i3 series smoke by offering detector remote maintenance and EZ Walk loop testing capabilities Ease 2W MOD2 mounts to a 4 back box for and easy installation Terminal blocks with SEMS screws assure a reliable connection 2W MOD2 allows communication to 2 wire i3 with any listed re alarm control panel in turn enables i3 detectors to initiate a remote signal when they are in need of cleaning to provide a visual indication of this condition at the and at the panel The 2W MOD2 also features EZ Walk loop test for 2 wire i3 series detectors function veri es the entire initiating loop wiring just the press of a button Inspection 2W MOD2 includes three LEDs green red and that provide status indication for the loop LEDs indicate the following Loop communication status Maintenance alert Alarm Freeze trouble EZ Walk test enabled Wiring fault 2W MOD2 mounts directly to 4 square electrical boxes NUMBER reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES Speci cations Voltage 12 24 V 8.5 V power limited 35 V power limited Ripple Voltage of nominal peak to peak Modes Color LED 1 sec on 1 sec off 1 sec on 1 sec off LED LED 0.5 sec on 0.5 sec off Up Sequence for LED Indication LED status indication Walk test available Standby Current mA Alarm Current mA Maintenance Current mA Contact Ratings A 36VDC Resistive Contact Ratings A 30VDC Resistive on Detectors on loop do not have communication on Detectors on loop are communicating normally not applied or module not in operation on loop in alarm or more detector on loop is in need of maintenance or in freeze trouble wiring fault exists Walk test mode minutes minutes after reset square back box Speci cations Temperature to 50 Humidity Range to 95 RH non condensing Terminals AWG 4.5 inches 114 mm 4.0 inches 101 mm 1.25 inches 32 mm oz 225 grams Information loop test maintenance module for 2 wire i3 Series standard sounder and C relay smoke detectors TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5129 4