Mircom CAT-5154 BEAM1224 Series Conventional Beam Smoke Detectors (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5154-beam1224-series-conventional-beam-smoke-detectors-english-2680319574.pdf |
---|---|
Type | |
Size | 1.02 MB |
Downloads |
Text Preview
CONVENTIONAL BEAM SMOKE DETECTORS BEAM1224 SERIES to 328 foot protection range re ective design friendly alignment procedure user selectable sensitivity levels integral NFPA 72 sensitivity test feature plug in terminal blocks display for easy alignment automatic gain control compensates for deterioration from dust build up test station optional cover alignment in the industry kits for transmitter receiver and re ector has four standard sensitivity selections with two Acclimate settings adjustable When one of the two Acclimate settings selected the detector will automatically adjust sensitivity using advanced software algorithms choose the optimum sensitivity for the speci c is also equipped with an integral test feature which consists of a test lter to a servo motor inside the detector optics the remote test station RTS451 is used the is activated and moves the lter into the pathway the light beam to test the detector sensitivity This sensitivity test feature allows the user to and easily meet the annual maintenance and requirements of NFPA 72 Sensor BEAM1224 is uniquely suited for open areas with high ceilings areas other methods of smoke detection are dif cult install and maintain BEAM1224 is a four wire conventional re ected smoke detector which is uniquely suited for open areas with high ceilings where other of smoke detection are dif cult to install and It is to be used with UL Listed compatible panels only An advantage of this single ended ective design is that it is much easier to install than dual ended projected beam detectors Alignment quickly accomplished via an optical sight and a signal strength meter incorporated into the Another advantage of the BEAM1224 is that is listed for operation in temperatures ranging from to 131 This means it can be used in open to provide early warning in environments where extremes may exceed the capability of types of smoke detectors consists of a transmitter receiver unit and re ector When smoke enters the area between the and the re ector the smoke causes a reduction the signal When the smoke level reaches the threshold an alarm is activated reserves the right to make changes at any time without notice in prices colours materials components equipment speci cations and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Speci cations Speci cations Range Angle Levels Level ft to 328 ft 5m to 100m 10 Degrees horizontal vertical optics move independent of the unit 25 2 30 3 40 4 50 Level 1 30 Level 2 40 or more obscuration blockage alignment mode initial alignment limit reached gunsight signal strength indication display red LED and remote alarm yellow LED and remote trouble ashing green LED Sensitivity Test Filter BEAM1224S lter Incremental scale on ector alarm test switch alarm reset switch test and reset switch Compatible RTS451 and RTS451KEY test station smooth ceilings 30 feet between beams and not more than one half spacing between a projected beam and a Other spacing may be used depending ceiling height air ow characteristics and requirements See NFPA 72 to 131 to 55 RH Noncondensing Condition Trouble Aid Indicator Indicator Indicator Features Detector Spacing Speci cations Speci cations to 32 VDC BEAM1224 to 32 VDC BEAM1224S should not be used 12V power sources Standby Current 24VDC Max Current During Testing Max Alarm Current 24VDC Max Fault Current 24VDC Max Alignment Mode Current 24VDC 28mA Max Speci cations Dimensions ector Dimensions 16 to 230 ector Dimensions beyond 230 Speci cations BEAMHK Consumption Speci cations BEAMHKR Consumption H 7.5 W 3.3 D H 191mm W 84mm D 9.1 200 230mm 18.1 400 460mm to 32V at 32V 24V 3W 32V to 32V Max at 32V per re ector 24V 15W 32V per re ector Parts Terminals COM N O COM N O OUT OUT IN IN INPUT INPUT ALARM OUT used TROUBLE OUT COM N C Test Feature only MOTOR FILTER Information wire conventional beam smoke detector with 8 ector wire conventional beam smoke detector with 8 ector and integral sensitivity test suf x for Canadian models range accessory kit 3 additional re ectors for applications in excess of 230 ft 70m kit Provides ceiling or wall mount with increased angular adjustment for either beam or the re ector When installed with the unit BEAMSMK must be used well mount kit kit for transmitter receiver unit electrical requirements above kit for re ector electrical requirements above test station with key lock test station used to initiate the NFPA sensitivity function TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com 5154 3