Mircom CAT-5176 D2 Innovairflex 2-Wire Photoelectric Duct Detector (English)

File Preview
File Preview
Click below to download for free

Text Preview

INNOVAIRFLEX 2 WIRE PHOTOELECTRIC DUCT DETECTOR integrated low flow technology velocity rating from 100 ft min to 4,000 ft min 0.5 m s 20.32 m sec mounting options in square or rectangular with modular construction sensor false alarm immunity with the latest sensor ranges for operating temperature 4 to 158 humidity 0 to 95 non condensing sampling tube installs from front or back of the with no tools required cover tamper feature to indicate a trouble condition for or improperly installed sensor cover wiring space with a newly added inch knockout LED status VDC compatibility with existing Innovair products remote accessories Specifications air duct smoke detector shall be a System Sensor D2 A Photoelectric Duct Smoke Detector detector housing shall be UL listed per UL 268A or listed specifically for use in air handling systems The housing of the duct smoke detector fits both square rectangular footprints The detector shall operate at air of 100 ft min to 4000 ft min 0.5 m sec to 20.32 m The unit shall be capable of providing a trouble signal the event that the sensor cover is removed or improperly It shall be capable of local testing via magnetic or remote testing using the RTS151KEY A remote station Terminal connections shall be of the strip and method suitable for 12 AWG wiring InnovairFlex D2 2 wire photoelectric duct smoke detector a pivoting housing that fits various applications both and rectangular footprints mount to round or rectangular work new duct smoke detector senses airflow speeds ranging 100 to 4,000 feet per minute with proven System Sensor The enhancements built into this model improve alarm immunity with plug in sensor head broaden temperature 4 to 158 and humidity 0 to 95 noncondensing ranges while simplifying installation maintenance These advance features can detect smoke in the harshest duct applications new design provides more wiring space with an added inch conduit knockout Numbers and labels for terminal are consistent with previous Innovair models The sampling tube can be clicked into position with one smooth from either the front or the back of the detector InnovairFlex D2 duct smoke detector has signals to indicate and maintenance conditions Additionally a cover tamper is incorporated to indicate a trouble condition for removed improperly installed sensor cover An improved cover design an integrated the low flow feature isolates the sensor head the low flow technology for simple maintenance InnovairFlex series is designed for greater flexibility and smoke detection to simplify installation and maintenance new InnovairFlex product line is backward compatible to Innovair models including remote test accessories Duct smoke detectors have specific limitations SMOKE DETECTORS ARE a substitute for an open area smoke detector a substitute for early warning detection and a replacement for a building regular fire detection system to NFPA 72 90A and CAN ULC S524 for additional duct detector application information reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Specifications Rectangular Square in 37 cm Length 5 in 12.7 cm Width in 6.36 cm Depth in 19.7 cm Length 9 in 22.9 cm 2.5 in 6.35 cm Depth lb 0.82 kg to 158 20 to 70 to 158 to 70 Temp Range Temp Range Humidity Range 0 to 95 relative humidity non condensing Duct Velocity to 4000 ft min 0.5 to 20.32 m sec Current Loads at 24 VDC for 2 wire Duct Smoke Detector wiring diagram for 2 wire duct smoke detectors powered from initiating device circuit LISTED 2 WIRE PANEL mA Max mA Max mA Max mA mA mA DETECTOR LOOP D2 DETECTOR LOOP D2 DETECTOR LOOP D2 Ratings supply voltage capacitance voltage time with RTS151 time up time response time Test Requirements Using No Accessories standby current standby current alarm current VDC max VDC min to 0.3 sec power down 0.3 sec max sec max sec detector label average mA the InnovairFlex Tube InnovairFlex sampling tube be installed from the front back of the detector The tube securely into place and can removed by releasing the front rear locking tab RESISTOR PANEL IN OUT IN OUT IN OUT OPTIONAL ALARM LED OPTIONAL ALARM LED VDC NOM ALARM VDC NOM ALARM OPTIONAL ALARM LED VDC NOM ALARM D OPTIONAL WIRING diagram for 2 wire duct smoke detector to RTS151 RTS151KEY Remote Test Station RED REMOTE STATION TEST COIL TEST COIL VDC POWER USER VDC POWER USER VAC 10 WAVE RECTIFIED POWER BE USED VAC 10 WAVE RECTIFIED POWER BE USED RED REMOTE STATION IN OUT RA RA RTS TEST COIL TEST COIL IN OUT RA RA RTS 1 AUX POWER LOCATED AT DUCT DETECTOR 2 AUX POWER LOCATED TEST STATION Note use of either RTS151 or RTS151KEY requires the installation of an accessory coil DCOIL sold separately refer to the D2 installation manual for more information Information photoelectric low flow duct smoke detector conventional photoelectric sensor head sampling tube duct width up to 1ft 0.3m sampling tube duct widths 1 ft to 2 ft 0.3 to 0.6 m sampling tube duct widths 2 ft to 4 ft 0.6 to 1.2 m sampling tube duct widths 4 ft to 8 ft 1.2 to 2.4 m sampling tube duct widths 8 ft to 12 ft 2.4 to 3.7 m TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 page http www mircom com Email mail mircom com Add suffix for Canadian models exhaust tube duct width 1ft 0.3m remote test coil required with RTS151 RTS151KEY annunciator alarm LED test station test station with key lock 5176 1

Related Files