Mircom CAT-5178 D4120 Innovairflex 4-Wire Photoelectric Duct Detector (English)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5178-d4120-innovairflex-4-wire-photoelectric-duct-detector-english-3196754208.pdf |
---|---|
Type | |
Size | 1.12 MB |
Downloads |
Text Preview
INNOVAIRFLEX 4 WIRE PHOTOELECTRIC DUCT DETECTOR integrated low flow technology velocity rating from 100 ft min to 4,000 ft min 0.5 m s 20.32 m sec mounting options in square or rectangular with modular construction sensor offers superb false alarm immunity and latest sensor technology ranges for operating temperature 4 to 158 humidity 0 to 95 non condensing sampling tube installs from front or back of the with no tools required wiring space with a newly added inch knockout easy access Test Reset button and improved LED interconnect feature for multi fan shutdown high contrast terminal designations short circuit protection from operator wiring errors selectable settings for configuring the detector DPDT Form C relay contacts VAC DC or 120 VAC compatibility with existing Innovair products remote accessories Specifications air duct smoke detector shall be a System Sensor D4120 A Photoelectric Duct Smoke The detector housing shall be UL listed per UL or ULC listed specifically for use in air handling The flexible housing of the duct smoke detector fits square and rectangular footprints The detector shall at air velocities of 100 ft min to 4000 ft min 0.5 m to 20.32 m sec The unit shall be capable of controlling to 50 air handling systems when interconnected with detectors The detector shall be capable of providing trouble signal in the event that the front cover is removed shall be capable of local testing via magnetic switch or testing using the RTS451KEY A remote test station connections shall be of the strip and clamp method for 12 AWG wiring InnovairFlex D4120 4 wire photoelectric duct smoke features a pivoting housing that fits both square and footprints and mounts to round or rectangular This unit senses smoke in the most challenging operating in airflow speeds of 100 to 4,000 feet per temperatures of to 158 and a humidity range of to 95 percent non condensing A plug in sensor head offers false alarm immunity and simple installation testing maintenance An improved cover design isolates the sensor from the low flow feature for simple maintenance InnovairFlex housing provides ample wiring space a conduit knockout and built in short circuit protection to damage to sensitive components during installation contrast terminal designations make wiring easy With its sensor to power capability the power board of the D4120 be used to monitor a second sensor D4S simultaneously supply and return side As many as 50 InnovairFlex can be interconnected When one unit senses smoke interconnected detectors will switch their relays only the sensing smoke will go into alarm thus pinpointing the source easy access Test Reset button makes it possible to test unit with the cover on Three DIP switches can be used to field selectable settings cover tamper delay number sensors to be controlled and shut down on trouble option power board has two LEDs that can be used to indicate status of connected sensors and a quick reference imprinted the cover explains the LED status indications Standby Trouble and Alarm The InnovairFlex duct detector can be customized to meet local codes and without additional wiring The new InnovairFlex line is compatible with all previous Innovair models remote test accessories Duct smoke detectors have specific limitations SMOKE DETECTORS ARE a substitute for an open area smoke detector a substitute for early warning detection and a replacement for a building regular fire detection system to NFPA 72 90A and CAN ULC S524 for additional duct detector application information reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER for 4 wire Duct Smoke Detector and Accessories INPUTS NOTE 1 INPUTS NOTE 1 CONTACTS FAN SHUTDOWN ETC NOTE 2 A B CONTACTS FAN SHUTDOWN ETC NOTE 2 A B CONTACTS 3 C N O CONTACTS 3 C N O RESISTOR BY LISTED PANEL 4 C N O 4 C N O DETECTOR IN THE LOOP DETECTOR IN THE LOOP 1 24V Power Inputs accept a non polarized or 24VAC 50 60Hz 120VAC Power Inputs only 120VAC 50 60Hz Connect power to appropriate terminals of each detector See for additional power supply information 2 Auxiliary contacts shown in standby position switch during alarm as indicated by arrows contacts are not to be used for connection the control panel See specifications for contact 3 Supervisory contacts shown in standby Open contacts indicate a trouble condition to panel See specifications for contact ratings 4 Alarm Initiation contacts shown in standby Closed contacts indicate an alarm condition the panel See specifications for contact ratings refer to the corresponding installation manual accessory wiring diagrams Current Loads at 24 VDC mA Max mA Max mA Max mA mA mA Ratings supply voltage capacitance voltage time with RTS451 time by power down up time response time Test Requirements Using No Accessories standby current alarm current VDC max VDC min to 0.3 sec sec max sec max sec detector label mA 24VDC mA 24VDC Specifications Rectangular Square Temp Range Temp Range in 37 cm Length 5 in 12.7 cm Width in 6.36 cm Depth in 19.7 cm Length 9 in 22.9 cm 2.5 in 6.35 cm Depth lb 1.14 kg D4S 4 to 158 20 to 70 40 to 158 40C to 70 D4S to 158 to 70 40 to 158 40C to 70 Humidity Range 0 to 95 relative humidity non condensing Duct Velocity to 4000 ft min 0.5 to 20.32 m sec Ratings initiation SPST auxiliary DPDT SPDT 30 VDC resistive 30 VDC resistive 10A 250 VAC resistive HP 240 VAC HP 120 VAC Alarm auxiliary contacts shall not be connected to circuits of control panels Use the alarm initiation for this purpose 30 VDC resistive 2.0A 125 VAC VAC 50 Hz max VAC min to 0.3 sec sec max sec max sec detector label VAC 50 Hz VAC min to 0.3 sec sec max sec max sec detector label mA RMS 24VAC 60Hz mA RMS 24VAC 60Hz mA RMS 120VAC 60Hz mA RMS 120VAC 60Hz Information Description photoelectric low flow duct smoke detector photoelectric sensor component only photoelectric power board component only 24 120 VAC conventional photoelectric sensor head sampling tube duct width up to 1ft 0.3m sampling tube duct widths 1 ft to 2 ft 0.3 to 0.6 m sampling tube duct widths 2 ft to 4 ft 0.6 to 1.2 m sampling tube duct widths 4 ft to 8 ft 1.2 to 2.4 m sampling tube duct widths 8 ft to 12 ft 2.4 to 3.7 m exhaust tube duct width 1ft 0.3m annunciator alarm LED test station test station with key lock Add