Mircom CAT-5277 FHS-400C Ceiling Mount LED Horn-Strobes (English)

File Preview
File Preview
Click below to download for free

Text Preview

CEILING MOUNT LED HORN STROBES SERIES Compact Design Advanced LED technology provides superior draw performance power consumption per device allows more notification appliances per circuit and the need for external power supplies Standard and High candela settings in one unit to virtually any application 15 75 30 75 110 cd Multiple field selectable audible settings Continuous March Time and 20 audible tones and Low volume settings Red or white finish Device settings are located on the back of the to prevent tampering shorting clip that allows installers to test wiring before the device is installed Supports 12 to 22 AWG Mount to Mircom BB 400 surface mount back single gang 4 inch square double gang and 4 inch junction boxes All units include universal mounting plate For indoor applications UL 1971 UL 1638 UL 464 ULC S525 ULC S526 NFPA 72 2016 Edition FHS 400C Series ceiling mount horn offer an audible visual solution that delivers energy efficiency in a compact design advanced LED technology the FHS 400C LED horn strobes provide a lower current which allows for more devices on a NAC while reducing the number of external power required FHS 400C Series horn strobes offer a wide range audible visual settings in a single compact device audible settings include Temporal Continuous Time and 20 BPM tones that can each be set Low or High volume settings The candela settings be field configured for 15 15 75 30 75 110 cd candela setting is displayed through the front for easy identification All device settings are on the back of the unit to prevent tampering FHS 400C Series horn strobes can be using a control panel with the Mircom protocol or the SDM 240 synchronization module FHS 400C Series notification appliances utilize universal mounting plate that allows for mounting a single gang double gang octagon 4 junction 4 square electrical box The back plate allows installer to mount the plate and connect the wire The device attaches to the mounting plate is secured by a single mounting screw In addition FHS 400C can mount to the Mircom BB 400 back for surface mount applications reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Specifications horn strobe shall be a Mircom FHS 400C notification appliance for ceiling mount applications The horn shall be of a low current draw design and operate at 24 VDC regulated or full wave rectified The horn shall have two field selectable volume settings and a choice of four tone settings for temporal continuous time or 20 BPM The horn strobe shall incorporate a Light Emitting Diode LED as the light source and five field selectable settings of 15 15 75 30 75 110 candela The candela settings shall show the candela in a visible location at all times when installed Both the audible and candela settings shall be tamper The horn strobe shall be synchronized using a control panel with the Mircom sync protocol or the sync module The horn strobe shall utilize a mounting plate that allows the installer to pre wire the plate The mounting plate shall mount on a single gang double gang octagon 4 inch square box or BB 400 series back box The horn strobe shall be listed to UL standard 464 Audible Signaling Devices Fire Alarm and Signaling Devices UL standard 1638 Visible Signaling Devices for Fire Alarm and Signaling and standard 1971 Signaling Devices for the Hearing Impaired In addition the horn strobe shall be to ULC S525 Audible Signal Devices for Fire Alarm Systems and ULC S526 Visible Signal Devices for Alarm Systems Series Dimensions 27 123 mm 27 123 mm 35 35 mm mm 61 61 mm mm 27 123 mm 35 mm mm mm 61 mm mm 39 117 mm 39 117 mm 39 117 mm 27 mm 37 37 mm mm 37 mm and width and width models models and width Mount Strobes Mount Strobes Horn Strobes models Horn Strobes FHS 400 FHS 400 Mount Strobes Mount Strobes Horn Strobes Horn Strobes Horn Strobes FHS 400C FHS 400C FHS 400 Horn Strobes FHS 400C Mount Strobes Plate Plate Mount Strobes Plate Dimensions Settings 27 123 mm switches for the volume and signal rate 27 mm dimensions 1 1 27 mm 51 mm setting switch settings are located on the back of the unit to prevent tampering TO BE USED FOR INSTALLATION PURPOSES 5277 2 of 4 Reverberant Ratings per UL464 dBA 10 ft Output Dispersion Ceiling Horn Strobe Operating RMS mA 24 VDC 24 VFWR Volume Volume tone volume is representative of March and 20BPM as well of Candela Rating Dispersion Dispersion The values are shown as percentages of the rated light output at any candela setting Specifications temperature range flash rate Voltage Voltage Range terminal wire gauge environment Ratings to 50 32 to 122 to 93 Hz 24 VDC 24 VFWR to 33 AWG to 12 AWG indoor use only BPM BPM Anechoic Ratings per CAN ULC S525 dBA 3 m Directional Sound Characteristics Axis 45 61 90 Axis 49 61 90 dbA dbA dbA dbA dbA dbA TO BE USED FOR INSTALLATION PURPOSES 5277 3 of 4 Information Number Mount Horn Strobe Red Mount Horn Strobe White Mount Back Box Red Mount Back Box White Module TO BE USED FOR INSTALLATION PURPOSES by Interchange Way Ontario L4K

Related Files