Mircom CAT-5321 - INX-10A - Intelligent NAC Expander Power Supply
File Preview
Click below to download for free
Click below to download for free
File Data
Name | mircom-cat-5321-inx-10a-intelligent-nac-expander-power-supply-0124659378.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
INTELLIGENT NAC EXPANDER POWER SUPPLY Works with listed compatible Series Intelligent Amp output 240V operation Alarm Control Units Easily configured using DIP switches One isolated input from the host panel Five Class B Style Y or Class A Style Z output circuits DC regulated outputs Configurable AC Power fail delay Ground fault enable or disable Option available on configuration to enable or the battery charger on activation From 7 to 15 Address functions Combination of inputs outputs depending on the application Outputs individually controllable Separate Relay for Ground Fault and Common available on terminals Horn Strobe synchronization protocols include Gentex System Sensor and Wheelock Two wire horn strobe Sync Mode allows audible appliances horns to be silenced visual notification appliances strobes to operate Audible signals may be configured for Steady Code California Code and March Time Output circuits four and five can be configured to auxiliary power for four wire detectors or holders Canadian two stage operation Output fault notification to fire alarm control panel Ability to sync outputs for multiple INX 10A units Built in charger for sealed lead acid or gel type Amp max current per output Amp auxiliary power output Unit includes power supply charger red door black transformer and battery leads Compatible with any UL ULC listed 24VDC fire alarm control panel to provide Appliance Circuit expansion NUMBER INX 10A is an Intelligent NAC expander supply that works with listed compatible fire alarm control panels Available in a 10 configuration the INX 10A can extend the power of existing notification appliance circuits well as provide power for other ancillary devices addition the INX 10A has the ability to operate with UL ULC Listed 24 VDC fire alarm control panel to Notification Appliance Circuit expansion INX 10A is equipped with five individual Class B Y or Class A Style Z output circuits that can be configured for NAC operation or auxiliary The INX 10A provides the option of configuring five circuits as an output to provide general purpose In addition output circuits four and five can configured to provide auxiliary power for four wire or door holders output circuit is rated for 2.5 Amps When for NAC operation the outputs can be set Steady Temporal Code California Code or March In addition the output circuits have field selectable strobe and horn synchronization protocols support Amseco System Sensor Wheelock and Gentex eliminating the need for additional external modules TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY Mode with Internal Sync Mode with External Sync Mode with Redundant Input of Operation NAC Expander INX Modes INX 10A features three modes of NAC Expander Mode with Internal Sync this mode all signal and sync strobe rates are produced in the Mode with External Sync one of the Sync Inputs is activated the INX 10A follow the signal pattern of the Sync Input The must be configured as a slave to operate in this Mode with Redundant Input system continuously monitors the SLC loop If there is no for a notable time an SLC trouble is generated While the trouble is active if either of the Sync Inputs are activated then NAC outputs follow x 14 x 4 Line Voltage 60Hz 240V 50Hz 2 Amps 1 Amp primary Circuits regulated Power Limited Total 2.5A maximum per circuit Gel Cell Sealed Lead Acid Capability to 40 AH batteries Consumption from INX 10 A Power Supply Consumption from Compatible FACP mA mA Supply Modes addition to the NAC expander modes some or all of NAC outputs on the INX 10A can be configured for the power supply modes of operation NAC Outputs as Power Supply Outputs NAC Outputs for Door Release NAC Outputs for 4 Wire Smoke Supply Outputs as Power Supply Outputs mode allows any NAC output to be configured as a supply The SLC and Sync inputs are ignored for the supply outputs Outputs for Door Release mode allows NAC circuits 4 and or 5 to provide power door holders Outputs for 4 Wire Smoke Supply mode allows NAC circuits 4 and or 5 to provide power for 4 wire smoke detectors Indicators On Line Activity Alarm Trouble Charger Trouble Fail LEDs Output Trouble Output Trouble Fault Trouble LEDs SLC Loop Indicators 3 LEDs Input Indicators 2 LEDs Synchronized Indicators 2 LEDs Trouble LED Indicator Relay Indicator Button DIP Switches Consumption from Compatible FACP Information NAC Expander 10 Amps c w backbox and red door NAC Expander 10 Amps Addressable Chassis Mounts into BB 5008 or BB 5014 enclosure Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES AND NOT INTENDED TO DESCRIBE THE TECHNICALLY complete and accurate installation testing and certification refer to technical This document contains intellectual property of Mircom information is subject to change by Mircom without notice does not represent or warrant correctness or completeness relating 5321 7