Mircom CAT-5321 INX-10A Intelligent NAC Expander Power Supply (English)

File Preview
File Preview
Click below to download for free

Text Preview

INTELLIGENT NAC EXPANDER POWER SUPPLY Works with listed compatible Series Intelligent Amp output 240V operation Alarm Control Units Easily configured using DIP switches One isolated input from the host panel Five Class B Style Y or Class A Style Z output circuits DC regulated outputs Configurable AC Power fail delay Ground fault enable or disable Option available on configuration to enable or the battery charger on activation From 7 to 15 Address functions Combination of and outputs depending on the application Outputs individually controllable Separate Relay for Ground Fault and Common available on terminals Horn Strobe synchronization protocols include Gentex System Sensor and Wheelock Two wire horn strobe Sync Mode allows audible appliances horns to be silenced visual notification appliances strobes to operate Audible signals may be configured for Steady Code California Code and March Time Output circuits four and five can be configured to auxiliary power for four wire detectors or holders Canadian two stage operation Output fault notification to fire alarm control panel Ability to sync outputs for multiple INX 10A units Built in charger for sealed lead acid or gel type Amp max current per output Amp auxiliary power output Unit includes power supply charger red door backbox transformer and battery leads Compatible with any UL ULC listed 24VDC fire alarm control panel to provide Appliance Circuit expansion INX 10A is an Intelligent NAC expander supply that works with listed compatible fire alarm control panels Available in a 10 configuration the INX 10A can extend the power of existing notification appliance circuits well as provide power for other ancillary devices addition the INX 10A has the ability to operate with UL ULC Listed 24 VDC fire alarm control panel to Notification Appliance Circuit expansion INX 10A is equipped with five individual Class B Y or Class A Style Z output circuits that can be configured for NAC operation or auxiliary The INX 10A provides the option of configuring five circuits as an output to provide general purpose In addition output circuits four and five can configured to provide auxiliary power for four wire or door holders output circuit is rated for 2.5 Amps When for NAC operation the outputs can be set Steady Temporal Code California Code or March In addition the output circuits have field selectable strobe and horn synchronization protocols to Amseco System Sensor Wheelock and Gentex eliminating the need for additional external modules INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY NUMBER Mode with Internal Sync Mode with External Sync Mode with Redundant Input of Operation NAC Expander INX Modes INX 10A features three modes of NAC Expander Mode with Internal Sync this mode all signal and sync strobe rates are produced the INX 10A Mode with External Sync one of the Sync Inputs is activated the INX 10A follow the signal pattern of the Sync Input The must be configured as a slave to operate in mode Mode with Redundant Input system continuously monitors the SLC loop If there is activity for a notable time an SLC trouble is generated the SLC trouble is active if either of the Sync Inputs activated then all NAC outputs follow x 14 x 4 Line Voltage 60Hz 240V 50Hz 2 Amps 1 Amp primary Circuits regulated Power Limited Total 2.5A maximum per circuit Gel Cell Sealed Lead Acid Capability to 40 AH batteries Consumption from INX 10 A Power Supply Consumption from Compatible FACP Loop SLC Information mA mA Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 www mircom com mail mircom com Supply Modes addition to the NAC expander modes some or all of NAC outputs on the INX 10A can be configured for following power supply modes of operation NAC Outputs as Power Supply Outputs NAC Outputs for Door Release NAC Outputs for 4 Wire Smoke Supply Outputs as Power Supply Outputs mode allows any NAC output to be configured as power supply The SLC and Sync inputs are ignored the power supply outputs Outputs for Door Release mode allows NAC circuits 4 and or 5 to provide for door holders Outputs for 4 Wire Smoke Supply mode allows NAC circuits 4 and or 5 to provide power for 4 wire smoke detectors Indicators On Line Activity Alarm Trouble Charger Trouble Fail LEDs Output Trouble Output Trouble Fault Trouble LEDs SLC Loop Indicators 3 LEDs Input Indicators 2 LEDs Output Indicators 2 LEDs LED Indicator Relay Indicator Button DIP Switches INFORMATION IS FOR MARKETING PURPOSES AND NOT INTENDED TO DESCRIBE THE PRODUCTS complete and accurate technical information relating performance installation testing and certification refer technical literature This document contains intellectual of Mircom The information is subject to change by without notice Mircom does not represent or warrant or completeness 5321 7 NAC Expander 10 Amps c w backbox and red door NAC Expander 10 Amps Addressable Chassis Mounts into BB 5008 or BB 5014 enclosure

Related Files