Mircom CAT-5620 FA-1000 Series Fire Alarm Control Panels (English)

File Preview
File Preview
Click below to download for free

Text Preview

FIRE ALARM CONTROL UNITS SERIES to UL 864 9th edition system capacity Modular design Each Indicating Circuit can be configured as or Non Silenceable Audibles may be configured as Steady Temporal California Code or March Time Each Initiating Circuit can be configured as Supervisory Waterflow or Trouble Two LEDs per Initiating circuit one for Trouble one for Status and Indicating Circuits may be disconnected by a DIP switch Configurable Signal Silence Inhibit Auto Signal Two Stage Operation and One Man Test Subsequent Alarm Supervisory and Trouble Two outputs for 4 wire resettable smoke power 200 mA Max each Auxiliary relay contacts for Common Alarm and Supervisory as well as a Common Relay Each relay contact Form C 28 1 Amp resistive RS 485 Interface for RA 1000 Remote Multiplex for Remote Trouble Indicator Easy configuration via push buttons and DIP on the front panel Fully site or field programmable Indicating and Auxiliary Relays Extensive Transient Protection Slide in labels for zone identification Removable door for easy installation and Amp or 12 Amp power supplies available Removable terminal blocks for easy wiring and Modules UDACT 300A Digital Communicator Module Polarity Reversal and City Tie Module FA 1000 Series Microprocessor Based Fire Control Panels are Multi Zone units designed maximum flexibility and easy installation and Fully configurable from the front panel push buttons and DIP switches the FA 1000 enables the user to configure the system to their specific requirements With a large capacity supervised Class A Style D or Class B Style B Circuits and supervised Class A Style Z Class B Style Y Indicating Circuits the FA 1000 is designed to meet virtually all applications FA 1000 Series consists of a Main Fire Alarm which houses and controls all other Additional modules may be installed to the system to meet any requirements that user may have The FA 1000 Series allows for Indicating Circuit Initiating Circuit and modules to be added to the system In addition allows for optional modules such as the UDACT Digital Communicator and the PR 300 Polarity Tie Module with Configuration DIP Switches on the Display Module the FA 1000 Series Fire Alarm Panels are configured through a combination DIP switch and button settings Through this method the user can define the system a Single Stage or Two Stage operation as well perform various functions such as a One Man Test reserves the right to make changes at any time without notice in prices colours materials components equipment specifications and models and also to discontinue models TO BE USED FOR INSTALLATION PURPOSES NUMBER Components Hardwire Modules MCC 1024 6ADS Main Control Unit comes with 8 Class B Style B or 4 Class A Style Initiating Circuits 4 Class A B Style Z Y Indicating a common control and zone identification board for up to 24 points and a 6 Amp Power which charges 10 24 AH batteries The is equipped with a 12 Amp Power which charges 17 40 AH batteries Both models with up to two adder modules of any plus one of a UDACT 300A Digital Communicator PR 300 Polarity Reversal City Tie Module Both mount in a UB 1024DS R backbox Eight Initiating Circuit Module DM 1008A provides 8 Style B Class B or 4 Style Class A Initiating Circuits configurable for Alarm or Trouble zones The DM 1008A occupies module slot Four Notification Appliance Circuit Module SGM 1004A provides 4 Style Z Y Class A B Appliance Circuits configurable as Silenceable Non Silenceable Each NAC circuit is rated at 1.7 Amps SGM 1004A occupies one module slot Eight Relay Circuit Module RM 1008A provides the FX 2003 12NXTDS with individual configurable relays per module Each relay one Form C contact rated at 28 VDC 1 Amp load as well as a Green LED to indicate that the is active The RM 1008A occupies one module slot Digital Alarm Communicator Module UDACT 300A Digital Alarm Communicator Module the FX 2003 12NXTDS to transmit addressable point to a central station The UDACT 300A occupies module slot MCC 1024 12XTDS Main Control Unit comes with 8 Class B Style B or 4 Class A Style Initiating Circuits 4 Class A B Style Z Y Indicating a common control and zone identification board for up to 72 points and a 12 Amp Supply which charges 17 40 AH batteries It is with up to eight adder modules of any type one of a UDACT 300A Digital Communicator or Polarity Reversal City Tie Module The MCC mounts in a BBX 1024XT R enclosure Polarity Reversal City Tie Module PR 300 Polarity Reversal City Tie Module provides system with a supervised City Tie and Polarity connection The PR 300 occupies one slot TO BE USED FOR INSTALLATION PURPOSES 5620 2 of 4 Series Enclosures Universal Backbox UB 1024DS Universal backbox houses the MCC 1024 and provides space to mount up to 17 AH A DOX 1024DS R door is ordered separately minus built in trim ring 26 x 14.5 x 4.2 Door DOX 1024DS mounts on the UB 1024DS backbox door features the universal CAT 30 lock and is in a white DOX 1024DS or red exterior DOX Series Remote Multiplex Annunciators Enclosure BBX 1024XT enclosure supports one MCC 1024 and up to 18 AH Batteries The enclosure features universal CAT 30 lock and a removable door for easy and servicing The enclosure is available in white BBX 1024XT or red exterior BBX 1024XTR FA XT TRB Semi Flush Trim Ring is required for flush mounting Dimensions 35 x 14 x 5 Main Remote LED Annunciator RAM 1032TZDS Main Remote LED Annunciator common annunciator functions and 32 points of annunciation The RAM 1032TZDS has indicators for On Common Trouble and Signal Silence and controls System Reset Lamp Test Fire Drill Buzzer Silence Signal Silence The RAM 1032TZDS occupies one position in the BB 1000 or BB 5000 enclosures Programmable LED Annunciator Module RAX 1048TZDS Programmable LED Annunciator provides 48 programmable bi colored LEDs RAX 1048TZDS connects to the main unit or either RAXN LCD or RAM 1032TZDS when mounted The RAX 1048TZDS occupies one display in the FX 2003 12NXTDS BB 1000 or BB 5000 enclosures for Annunciator Module Enclosures x 12.75 x 1.2 x 12.75 x 1.2 x 12.75 x 1.2 x 22.5 x 1.25 x 22.5 x 1.25 Main Remote LED Annunciator RAM 1016TZDS Remote LED Annunciator provides points of LED annunciation as well as 16 trouble LEDs RAM 1016TZDS has indicators for A C On Common and Signal Silence and controls for System Reset Test Fire Drill Buzzer Silence and Signal Silence The mounts in a BB 1000 series enclosure TO BE USED FOR INSTALLATION PURPOSES 5620 3 of 4 Ratings Line Voltage Supply Ratings Indicating Circuits Capability Consumption Information Control Unit Modules Modules Annunciators 60Hz 240V 50 Hz 2A 1A primary Amps max secondary unfiltered 5 Amps maximum AH batteries mA mA Line Voltage S

Related Files